Plan Review Details - Permit 01090278
Plan Review Stops For Permit 01090278
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2001-11-21 Cont ID  
Sent By jgomez Date 2001-11-21 Time 18:05 Rev Time 0.25
Received By jgomez Date 2001-11-21 Time 18:05 Sent To  
Notes
2001-11-21 00:00:00TRUSS DRAWINGS REVIEW.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2001-11-15 Cont ID  
Sent By jgomez Date 2001-11-15 Time 13:57 Rev Time 0.25
Received By jgomez Date 2001-11-15 Time 13:57 Sent To  
Notes
2001-11-15 00:00:00KNEE WALL IN DINING AREA REVISION.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2001-11-14 Cont ID  
Sent By jgomez Date 2001-11-14 Time 15:37 Rev Time 0.50
Received By jgomez Date 2001-11-14 Time 15:37 Sent To  
Notes
2001-11-14 00:00:00TRUSS DRAWINGS CHECKLIST:
  
 1-ENGINEERED TRUSSES ARE DESIGNED USING
 DIFFERENT MEAN ROOF HEIGHTS. THERE
 IS ONLY ONE MEAN ROOF HEIGHT FOR
 ENTIRE BUILDING. REVIEW ALL ENGINEERED
 TRUSSES AND REVISE AS REQUIRED.
 TABLE 1606.2A SBC 1997.
 2-SOME TRUSSES ARE DESIGNED USING "WALL
 HEIGHT" INSTEAD OF MEAN ROOF HEIGHT.
 WALL HEIGHT APPLIES ONLY TO FLAT ROOF
 SYSTEMS. MEAN ROOF HEIGHT IS USED FOR
 SLOPED ROOF. REVISE AS REQUIRED.
  
 NOTES:
 -THESE COMMENTS HAVE BEING ADDRESED ON
 PREVIOUS REVIEWS.
 -DRAWINGS TO BE FILED UNDER PERMIT #
 01090278.
 -THESE COMMENTS APPLY TO PERMIT #S:
 01090278, 01090280, 01090282, 01090284
 AND 01090288.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2001-10-01 Cont ID  
Sent By jgomez Date 2001-10-01 Time 17:18 Rev Time 1.00
Received By jgomez Date 2001-10-01 Time 17:17 Sent To  
Notes
2001-10-01 00:00:00APPROVED WITH PROVISO:
 1-FLOOD ZONE AO. WILL NEED THE ELEVATION
 CERTIFICATE.
 2-PROVIDE CERTIFICATION FOR TWO HOUR
 CONCRETE BLOCK. SEC 709.3 SBC 1997.
  
  
  
  
  
  
 NOTES:
 -DRAWINGS TO BE FILED UNDER PERMIT
 NUMBER 01090278.
 -THESE COMMENTS APPLY TO PERMIT #S:
 01090278, 01090280, 01090282, 01090284
 AND 01090288.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-09-28 Cont ID  
Sent By dpalmer Date 2001-09-28 Time 08:17 Rev Time 0.00
Received By dpalmer Date 2001-09-28 Time 08:17 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2001-09-17 Cont ID  
Sent By mcarsill Date 2001-09-17 Time 12:22 Rev Time 0.00
Received By mcarsill Date 2001-09-17 Time 12:22 Sent To  
Notes
2001-09-17 00:00:001) WET FIRE HYDRANTS REQUIRED PRIOR TO,
 DURING AND AFTER CONSTRUCTION.
 2) BUILDING ADDRESSES REQUIRED.
 3) ELECTRIC POWERED SMOKE DETECTORS
 REQUIRED.
 4) PORTABLE FIRE EXTINGUISHERS REQUIRED.
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2001-11-15 Cont ID  
Sent By ndenmark Date 2001-11-15 Time 14:03 Rev Time 0.50
Received By ndenmark Date 2001-11-15 Time 14:03 Sent To  
Notes
2001-11-15 00:00:00REVISIONS FOR LOT 45, 46, 47, 48, AND 49

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-11-12 Cont ID  
Sent By hmoser Date 2001-11-12 Time 12:42 Rev Time 0.33
Received By hmoser Date 2001-11-12 Time 12:42 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-09-22 Cont ID  
Sent By hmoser Date 2001-09-22 Time 10:49 Rev Time 0.33
Received By hmoser Date 2001-09-22 Time 10:49 Sent To  
Notes
2001-09-22 00:00:00NO MECHANICAL PERMIT NUMBER ON
 APPLICATION

Review Stop P PLUMBING
Rev No 1 Status P Date 2001-09-20 Cont ID  
Sent By kstevens Date 2001-09-20 Time 17:38 Rev Time 0.50
Received By kstevens Date 2001-09-20 Time 17:38 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2001-09-17 Cont ID  
Sent By sgraham Date 2001-09-17 Time 11:40 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***