Plan Review Stops For Permit 01090278 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2001-11-21 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2001-11-21 |
Time |
18:05 |
Rev Time |
0.25 |
Received By |
jgomez |
Date |
2001-11-21 |
Time |
18:05 |
Sent To |
|
|
Notes |
2001-11-21 00:00:00 | TRUSS DRAWINGS REVIEW. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2001-11-15 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2001-11-15 |
Time |
13:57 |
Rev Time |
0.25 |
Received By |
jgomez |
Date |
2001-11-15 |
Time |
13:57 |
Sent To |
|
|
Notes |
2001-11-15 00:00:00 | KNEE WALL IN DINING AREA REVISION. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2001-11-14 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2001-11-14 |
Time |
15:37 |
Rev Time |
0.50 |
Received By |
jgomez |
Date |
2001-11-14 |
Time |
15:37 |
Sent To |
|
|
Notes |
2001-11-14 00:00:00 | TRUSS DRAWINGS CHECKLIST: | | | | 1-ENGINEERED TRUSSES ARE DESIGNED USING | | DIFFERENT MEAN ROOF HEIGHTS. THERE | | IS ONLY ONE MEAN ROOF HEIGHT FOR | | ENTIRE BUILDING. REVIEW ALL ENGINEERED | | TRUSSES AND REVISE AS REQUIRED. | | TABLE 1606.2A SBC 1997. | | 2-SOME TRUSSES ARE DESIGNED USING "WALL | | HEIGHT" INSTEAD OF MEAN ROOF HEIGHT. | | WALL HEIGHT APPLIES ONLY TO FLAT ROOF | | SYSTEMS. MEAN ROOF HEIGHT IS USED FOR | | SLOPED ROOF. REVISE AS REQUIRED. | | | | NOTES: | | -THESE COMMENTS HAVE BEING ADDRESED ON | | PREVIOUS REVIEWS. | | -DRAWINGS TO BE FILED UNDER PERMIT # | | 01090278. | | -THESE COMMENTS APPLY TO PERMIT #S: | | 01090278, 01090280, 01090282, 01090284 | | AND 01090288. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2001-10-01 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2001-10-01 |
Time |
17:18 |
Rev Time |
1.00 |
Received By |
jgomez |
Date |
2001-10-01 |
Time |
17:17 |
Sent To |
|
|
Notes |
2001-10-01 00:00:00 | APPROVED WITH PROVISO: | | 1-FLOOD ZONE AO. WILL NEED THE ELEVATION | | CERTIFICATE. | | 2-PROVIDE CERTIFICATION FOR TWO HOUR | | CONCRETE BLOCK. SEC 709.3 SBC 1997. | | | | | | | | | | | | | | NOTES: | | -DRAWINGS TO BE FILED UNDER PERMIT | | NUMBER 01090278. | | -THESE COMMENTS APPLY TO PERMIT #S: | | 01090278, 01090280, 01090282, 01090284 | | AND 01090288. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2001-09-28 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-09-28 |
Time |
08:17 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-09-28 |
Time |
08:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2001-09-17 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2001-09-17 |
Time |
12:22 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2001-09-17 |
Time |
12:22 |
Sent To |
|
|
Notes |
2001-09-17 00:00:00 | 1) WET FIRE HYDRANTS REQUIRED PRIOR TO, | | DURING AND AFTER CONSTRUCTION. | | 2) BUILDING ADDRESSES REQUIRED. | | 3) ELECTRIC POWERED SMOKE DETECTORS | | REQUIRED. | | 4) PORTABLE FIRE EXTINGUISHERS REQUIRED. | | | | MIKE CARSILLO, CAPTAIN | | 659-8096,EXT.8497 | | 835-2910 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2001-11-15 |
|
|
Cont ID |
|
Sent By |
ndenmark |
Date |
2001-11-15 |
Time |
14:03 |
Rev Time |
0.50 |
Received By |
ndenmark |
Date |
2001-11-15 |
Time |
14:03 |
Sent To |
|
|
Notes |
2001-11-15 00:00:00 | REVISIONS FOR LOT 45, 46, 47, 48, AND 49 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2001-11-12 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2001-11-12 |
Time |
12:42 |
Rev Time |
0.33 |
Received By |
hmoser |
Date |
2001-11-12 |
Time |
12:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2001-09-22 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2001-09-22 |
Time |
10:49 |
Rev Time |
0.33 |
Received By |
hmoser |
Date |
2001-09-22 |
Time |
10:49 |
Sent To |
|
|
Notes |
2001-09-22 00:00:00 | NO MECHANICAL PERMIT NUMBER ON | | APPLICATION |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2001-09-20 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2001-09-20 |
Time |
17:38 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2001-09-20 |
Time |
17:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2001-09-17 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2001-09-17 |
Time |
11:40 |
Rev Time |
0.25 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|