Plan Review Details - Permit 01080991
Plan Review Stops For Permit 01080991 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2001-09-13 |
|
|
Cont ID |
|
Sent By |
hpiskura |
Date |
2001-09-13 |
Time |
09:13 |
Rev Time |
0.00 |
Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2001-10-09 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-10-09 |
Time |
17:26 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-10-09 |
Time |
17:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2001-09-24 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-08-30 |
Time |
15:57 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-08-30 |
Time |
15:57 |
Sent To |
|
|
Notes |
2001-08-30 00:00:00 | ****************** UNSAT *************** | | | | 1)NOTE: PLEASE NOTE THAT ALL BRANCH | | CIRCUIT #`S ARE TO BE SHOWN ON PLANS AND | | CORRELATE WITH SUBMITTED PANEL SCHEDULES | | | | | | 2)NOTE: PLEASE NOTE, WHAT IS THE SIZE OF | | EXISTING MAIN AND LOAD? PLANS SHOW | | ADDING NEW PANEL "B". PLEASE CLARFIY | | | | 3)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | ALL NEW EQUIPMENT BEING INSTALLED. | | MAINS/PANELS/BREAKERS MUST BE RATED FOR | | THE AVAILABLE FAULT CURRENT PER 110-9. | | PLEASE NOTE THAT AIC RATINGS WERE SHOWN | | FOR PANELS BUT NOT FOR MAINS. | | | | 4)NOTE: PLEASE NOTE CLEARENCES ON PLANS | | FOR DISCONNECT SHOWN FOR AHU #2. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
N |
Date |
2001-09-13 |
|
|
Cont ID |
|
Sent By |
hpiskura |
Date |
2001-09-13 |
Time |
09:13 |
Rev Time |
0.00 |
Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2001-08-20 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2001-08-20 |
Time |
16:59 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2001-08-20 |
Time |
16:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2001-09-13 |
|
|
Cont ID |
|
Sent By |
hpiskura |
Date |
2001-09-13 |
Time |
09:13 |
Rev Time |
0.00 |
Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2001-10-26 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2001-10-26 |
Time |
17:40 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2001-10-26 |
Time |
17:40 |
Sent To |
|
|
Notes |
2001-10-26 00:00:00 | PASSED/PROVISO | | | | 1) CONDENSATE EXISTING. INSPECTOR TO SEE | | IF IT MEETS CODE. AS BUILTS REVISION TO | | FOLLOW FOR 2ND ROUGH INSPECTION. | | | | 2) WATER LINES EXISTING. INSPECTOR TO | | SEE IF THEY MEET CODE. NEW WATER LINES | | WILL HAVE WATER HAMMER ARRESTORS PLACED | | NEAR FIXTURES. RISER DIAGRAM AS BUILTS | | TO BE SUBMITTED FOR 2ND ROUGH. | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT. 8377 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2001-10-23 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2001-10-23 |
Time |
10:53 |
Rev Time |
1.25 |
Received By |
kstevens |
Date |
2001-10-23 |
Time |
10:53 |
Sent To |
|
|
Notes |
2001-10-23 00:00:00 | DENIED | | REFERENCE: SPC-94 - FACBC-97 | | | | 1) FULL SETS OF PLANS REQUIRED. PAGE A-2 | | NOT INCLUDED IN RESUBMITED SET, AND DEMO | | PAGES NEED TO BE INSERTED. PLEASE SUBMIT | | FULL SETS FOR REVIEW. | | 2) PAGE A-1, RM 111. DOOR OUT OF ROOM | | SO AS NOT TO SWING INTO TURNING RADIUS. | | FACBC-97 4.22.3 | | 3) PAGE A-1 LUNCH ROOM. CLEAR FLOOR | | SPACE FOR PARALLEL, FIXTURE MUST CENTER | | ON CLEAR FLOOR SPACE. SINK ONLY 18" INTO | | CLEAR FLOOR SPACE. FRONTAL APPROACH IS | | REQUIRED. PLEASE SHOW DETAIL AND SHOW | | COMPLIANCE WITH ALL DETAILS OF SEC 4.24 | | 4) PLEASE SHOW WATER RISER DIAGRAM AS | | REQUESTED IN PREVIOUS PLAN REVIEW. NOTE | | #7 IN PLUMBING NOTES ON PAGE E-1 CALLS | | FOR AIR CHAMBERS, BUT NOTE BY SANITARY | | RISER CALLS FOR AIR HAMMER ARRESTORS. IF | | WATER HAMMER ARRESTORS ARE USED PLEASE | | NOTE IN NOTE #7 AND SHOW THEM IN WATER | | RISER DIAGRAM. PLACEMENT AND SIZE SHALL | | BE PER MANUFACTURES INSTALLATION INSTRU- | | CTIONS AND WH-PDI 201. PLACEMENT SHALL | | BE CLOSE TO FIXTURE NOT AT TOP OF DROP. | | 5) PAGE E-1 NOTE #4. FROM PREVIOUS RE- | | VIEW SHOW CONDENSATE SYSTEM SO PLUMBING | | CONTRACTOR CAN INSTALL. SHOW TERMINATION | | OF CONDENSATE. | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT. 8377 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2001-08-27 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2001-08-27 |
Time |
17:34 |
Rev Time |
1.50 |
Received By |
jleech |
Date |
2001-08-27 |
Time |
17:34 |
Sent To |
|
|
Notes |
2001-08-27 00:00:00 | DENIED; | | 1.NEW HANDICAP BATHROOM #104. DOOR SHALL | | BE DIAGONAL TO THE WATER CLOSET. FACBC | | 4.17.3. | | 2.LUNCH ROOM. SHOW CLEAR FLOOR SPACE FOR | | SINK FACBC 4.24.5. | | 3.SHOW WATER RISER DIAGRAM. SIZE ALL | | PIPE. SHOW LOCATION OF AIR HAMMER | | ARRESTERS AND SIZE PER. MANUFACTORS | | RECOMMENDATIONS. SPC 104.1.2. | | 4.SANITARY RISER DIAGRAM. PIPE UNDER | | SLAB SHALL BE MINIMUM OF TWE INCH. | | SPC 714.4. | | 5.PLUMBING NOTE #4. SHOW CONDENSATE | | SYSTEM SO PLUMBING CONTRACTOR KNOWS | | HOW TO INSTALL. SHOW WHERE CONDENSATE | | TERMINATES. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 659-8096 EXT.8369 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2001-09-13 |
|
|
Cont ID |
|
Sent By |
hpiskura |
Date |
2001-09-13 |
Time |
09:14 |
Rev Time |
0.00 |
Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |