Plan Review Details - Permit 01080720
Plan Review Stops For Permit 01080720
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2001-09-05 Cont ID  
Sent By hpiskura Date 2001-09-05 Time 14:06 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2001-09-13 Cont ID  
Sent By dpalmer Date 2001-09-13 Time 09:54 Rev Time 0.00
Received By dpalmer Date 2001-09-13 Time 09:54 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2001-08-21 Cont ID  
Sent By dpalmer Date 2001-08-21 Time 17:32 Rev Time 0.00
Received By dpalmer Date 2001-08-21 Time 17:32 Sent To  
Notes
2001-08-21 00:00:00*************** UNSAT ************
  
 1)NOTE: PLEASE NOTE THAT PLANS SUBMITTED
 FOR ELECTRICAL REVIEW WERE NOT CLEAR
 ENOUGH IN DETAIL FOR PROPER REVIEW.
 PLEASE SUBMIT PLANS FOR ELECTRICAL
 LAYOUTS. PLEASE NOTE THAT PLANS NEED TO
 BE RE-DRAWN UNDER COUNTY-WIDE AND CITY-
 WIDE ADMINISTRATIVE CODE 104.2.7.
  
 PLEASE NOTE THAT THE FOLLOWING ARE SOME
 ITEMS THAT COULD BE SEEN ON PAGE 1 OF 2
 OF THE ELEC SUBMITTED.
  
 1) NOTE: SMOKE DETECTORS ARE REQUIRED
 INSIDE AND OUTSIDE ALL SLEEPING ROOMS.
 ALSO ON EACH LEVEL OF A MULTI-LEVEL
 DWELLING UNIT. ROOMS WITH BATHS AND OR
 CLOSETS ARE CONSIDERED SLEEPING ROOMS.
 PER NFPA-72 2-2.1.1.1.
 PLEASE SHOW DOORS TO ALL BEDROOMS.
  
 2) NOTE: PLEASE LIST THE REQ`D BATH(S)
 CIRCUIT(S) PER 210-11-C-3.
 MUST BE 20A AND #12AWG.
  
 3) NOTE: PLEASE SHOW ALL OUTLETS SERVING
 KITCHEN COUNTERSPACE AS GFI/GFI PROTECT-
 -ED PER 210-8-A-6.
  
 4) PLEASE NOTE EITHER MISSING EGRESS
 LIGHTING AND/OR CLARIFY EGRESS LIGHTING
 PER 210-70 OF THE NEC.
 PLEASE DRAW IN SWITCH LEGS AND SHOW
 DEVICES THAT ARE BEING USED.
  
 5)NOTE: PLEASE PROVIDE CLARIFICATION ON
 PANELS AND IF NEW EQUIPMENT IS BEIING
 INSTALLED? EXISTING? RE-PULLING
 CONDUCTORS??
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2001-08-28 Cont ID  
Sent By lsmith Date 2001-08-28 Time 08:54 Rev Time 0.00
Received By lsmith Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2001-08-20 Cont ID  
Sent By mcarsill Date 2001-08-20 Time 16:23 Rev Time 0.00
Received By mcarsill Date 2001-08-20 Time 16:23 Sent To  
Notes
2001-08-20 00:00:001) FIRE DAMAGED APARTMENT(S) TO BE
 EQUIPPED WITH ELECTRIC POWERED
 SMOKE DETECTOR. WHEN ACTIVATED,THIS
 DETECTOR IS TO BE AUDIBLE IN THE
 SLEEPING ROOMS OF THAT UNIT.
 2) UNIT DOOR(S) TO BE FIRE RATED AND
 BE EQUIPPED WITH A SELF-CLOSING DEVICE.
  
 MIKE CARSILLO,CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-09-14 Cont ID  
Sent By pkrauss Date 2001-09-14 Time 11:29 Rev Time 0.30
Received By pkrauss Date 2001-09-14 Time 11:29 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2001-08-20 Cont ID  
Sent By pkrauss Date 2001-08-20 Time 12:22 Rev Time 0.40
Received By pkrauss Date 2001-08-20 Time 12:06 Sent To  
Notes
2001-08-20 00:00:00*******************DENIED***************
 MECHANICAL PERMIT 01080720
  
 INSUFFICIENT INFORMATION FOR MECHANICAL
 REVIEW.PLEASE PROVIDE THE FOLLOWING
 INFORMATION FOR REVIEW:
  
 1.PLAN INDICATING DUCTWORK (MATERIAL,
 SIZE, & R-VALUE).
  
 2.SIZE OF NEW GRILLS.
  
 3.CFM DISTRIBUTION.
  
 4.SIZE AND LOCATION OF RETURN AIR
 GRILL.
  
 5.LOCATION OF AHU.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT
 PATTY KRAUSS AT 659-8096 EXT. 8388.

Review Stop P PLUMBING
Rev No 1 Status P Date 2001-08-17 Cont ID  
Sent By kstevens Date 2001-08-17 Time 19:06 Rev Time 1.00
Received By kstevens Date 2001-08-17 Time 19:05 Sent To  
Notes
2001-08-17 00:00:00PROVISO...
  
 1) CALL FOR MISC. PRE-INSPECTION TO
 ASSESS WORK TO BE DONE.
  
 2) CALL FOR MISC. INSPECTION BEFORE ANY
 NEW WORK STARTS TO SEE INSIDE WALLS TO
 INSPECT FOR DAMAGE TO DWV AND WATER
 LINES AND TO SEE IF ANY STRAPING, SECUR-
 ING, OR ISOLATION OF PIPES IS NECESSARY.
  
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT.8377

Review Stop Z ZONING
Rev No 1 Status N Date 2001-08-28 Cont ID  
Sent By lsmith Date 2001-08-28 Time 08:54 Rev Time 0.00
Received By lsmith Date   Time   Sent To  
Notes
***NONE***