Plan Review Details - Permit 01080631
Plan Review Stops For Permit 01080631 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2001-08-17 |
|
|
Cont ID |
|
Sent By |
mamini |
Date |
2001-08-17 |
Time |
08:35 |
Rev Time |
0.00 |
Received By |
mamini |
Date |
2001-08-17 |
Time |
08:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2001-08-21 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-08-21 |
Time |
16:36 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-08-21 |
Time |
16:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
P |
Date |
2001-08-17 |
|
|
Cont ID |
|
Sent By |
mamini |
Date |
2001-08-17 |
Time |
08:08 |
Rev Time |
0.00 |
Received By |
mamini |
Date |
2001-08-17 |
Time |
08:08 |
Sent To |
|
|
Notes |
2001-08-17 00:00:00 | PASSED WITH PROVISOS: | | 1. SHEET C-3 SHOWS A GATE AT CONCRETE | | DRIVEWAY, IS THIS EXISTING GATE OR NEW, | | IF NEW PLEASE SHOW DETAILS. | | 2. PLEASE SHOW LOCATION FOR THE NEW | | ENTRY SIGN ON CIVIL SHEETS. | | 3. PLEASE CALL OUT THE FIXED AND | | REMOVABLE BOLLARDS ON CIVIL SHEETS | | 4. PLEASE SHOW DETAILS, SIZE OF THE | | DRAINAGE FOR ADA DRINKING FOUNTAIN. | | 5. IS THE WOOD RAIL FENCE WILL CONTINUE | | IN FRONT OF THE CONCRETE DRIVEWAY? NOT | | CLEAR, PLEASE VERIFY. | | 6. SHEET C-5 ; REDUCED PRESSURE | | PREVENTER, TITLE INDICATES 1" DUAL, BUT | | A SINGLE REDUECED PRESSURE IS SHOWN. | | WE RECOMMEND A SINGLE FOR THIS TYPE OF | | PROJECTS. | | | | IF ANY QUESTIONS PLEASE CONTACT 659-8096 | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2001-08-15 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2001-08-15 |
Time |
12:31 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2001-08-15 |
Time |
12:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2001-08-17 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2001-08-17 |
Time |
17:23 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2001-08-17 |
Time |
17:23 |
Sent To |
|
|
Notes |
2001-08-17 00:00:00 | PROVISO... | | | | 1) PROVIDE INFORMATION FOR DRAINAGE FOR | | DRINKING FOUNTAIN. | | | | 2) SUBMIT INFORMATION FOR RPZ BACKFLOW. | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT. 8377 |
|
|
|