Plan Review Stops For Permit 01080609 |
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
N |
Date |
2001-10-11 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-10-11 |
Time |
14:38 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-10-11 |
Time |
14:38 |
Sent To |
|
|
Notes |
2001-10-11 00:00:00 | ELECTRICAL REVIEW PULLED FROM MASTER | | IN ORDER TO PRINT BLDG PERMIT. | | | | SEPARATE PERMIT APPLICATION AND NEW | | PLANS WILL BE REQ`D TO BE SUBMITTED | | BEFORE ANY ELECTRICAL IS TO BE DONE. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2001-10-09 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-10-09 |
Time |
21:37 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-10-09 |
Time |
21:37 |
Sent To |
|
|
Notes |
2001-10-09 00:00:00 | ***************** UNSAT ************** | | | | 1)NOTE: PLEASE NOTE, PLANS ARE JUST NOW | | BEING SUBMITTED WITH AN ELECTRICAL | | RISER DIAGRAM/PANEL SCHEDULE AND LOAD | | CALCULATIONS. | | | | 2) NOTE: PLEASE LIST THE REQ`D BATH(S) | | CIRCUIT(S) PER 210-11-C-3. | | MUST BE 20A AND #12AWG. | | | | 3)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | ALL NEW EQUIPMENT BEING INSTALLED. | | MAINS/PANELS/BREAKERS MUST BE RATED FOR | | THE AVAILABLE FAULT CURRENT PER 110-9. | | | | 4)NOTE: PLEASE SHOW GROUNDING ELECTRODE | | GOING TO BUILDING STEEL AND COLD WATER | | PER 250-50. | | | | 5)NOTE: PLEASE NOTE THAT RISER SHOWS AN | | EQUIPMENT GROUNDING CONDUCTOR BEING | | INSTALLED BETWEEN METER AND FIRST MEANS | | OF DISCONNECT? PLEASE NOTE THAT THIS IS | | PARALLELING THE NEUTRAL. | | | | PLEASE SUBMIT THE ABOVE INFORMAITON FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2001-08-23 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-08-23 |
Time |
16:01 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-08-23 |
Time |
16:01 |
Sent To |
|
|
Notes |
2001-08-23 00:00:00 | ***************** UNSAT *************** | | | | 1) NOTE: PLEASE SHOW ALL OUTLET SPACING | | TO MEET 2`,6`,12` RULE PER 210-52. | | PLEASE SEE MISSING LOCATIONS THROUGHOUT. | | | | 2) PLEASE NOTE MISSING OUTLET FOR A/C | | EQUIPMENT PER 210-63 OF NEC AND 309.1 | | MECHANICAL CODE. | | | | 3)NOTE: PLEASE NOTE THAT SMOKE DETECTORS | | ARE TO BE INSTALL A MIN OF 3` FROM | | BATHS/ PER NFPA-72 2-5.2.1.6 | | | | 4)NOTE: PLEASE NOTE MISSING OUTLET FOR | | GARAGE PER 210-52G AND GFI PER 210-8. | | | | 5)NOTE: PLEASE NOTE THAT NO RISER | | DIAGRAM WAS SUBMITTED FOR REVIEW???? | | PLEASE NOTE THAT NO LOAD CALCULATIONS | | WERE SUBMITTED. 215-5 | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELELCTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2001-10-08 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2001-10-08 |
Time |
10:17 |
Rev Time |
0.30 |
Received By |
hmoser |
Date |
2001-10-08 |
Time |
10:17 |
Sent To |
|
|
Notes |
2001-10-08 00:00:00 | NO MECHANICAL PERMIT NUMBER ON THIS | | APLICATION |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2001-08-21 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2001-08-21 |
Time |
18:35 |
Rev Time |
0.33 |
Received By |
hmoser |
Date |
2001-08-21 |
Time |
18:35 |
Sent To |
|
|
Notes |
2001-08-21 00:00:00 | PLAN DENIED | | #1 NO DUCT SIZE ON PLAN | | #2 EXHAUST FANS MUST BE INSTALLED IN | | BATHROOMS WITH WINDOWS LESS THAN | | 3 SQ. FT. OF OPEN AREA | | PLAN REVIEW BY HAROLD MOSER | | [561]659-8096 EXT.8390 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2001-12-16 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
2001-12-16 |
Time |
09:08 |
Rev Time |
1.00 |
Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-12-16 00:00:00 | REVISION, APPROVED.PES |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2001-10-05 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2001-10-05 |
Time |
17:52 |
Rev Time |
0.33 |
Received By |
kstevens |
Date |
2001-10-05 |
Time |
17:52 |
Sent To |
|
|
Notes |
2001-10-05 00:00:00 | PASSED/PROVISO | | | | SUBMIT REVISION IF INSTALLED DIFFERENT | | THAN SANT RISER. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2001-08-18 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2001-08-18 |
Time |
07:02 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2001-08-18 |
Time |
07:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
7 |
Status |
P |
Date |
2002-03-11 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2002-03-11 |
Time |
13:39 |
Rev Time |
1.00 |
Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2002-03-11 00:00:00 | TRUSSES OK W/LETTER FROM ENGINEER, | | DESIGNER OF RECORD FOR STRUCTURE. | | 3-11-01 RM |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
6 |
Status |
F |
Date |
2002-03-06 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2002-03-06 |
Time |
08:51 |
Rev Time |
2.00 |
Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2002-03-06 00:00:00 | *************TRUSSES DENIED************* | | | | 1) THE TRUSS DRAWINGS ARE REQUIRED TO | | HAVE THE EMBOSSED SEAL OF THE TRUSS | | ENGINEER. | | | | 2) PLEASE CORRECT WINDLOAD LISTED ON THE | | TRUSS LAYOUT TO THE SAME AS THAT LISTED | | ON THE TRUSS DRAWINGS. | | | | 3) THE DESIGNER OF RECORD FOR THE | | STRUCTURE IS REQUIRED TO STAMP, SIGN AND | | DATE THE TRUSS LAYOUT. THE STAMP SHOULD | | STATE THAT THE LAYOUT AND DRAWINGS HAVE | | BEEN REVIEWED AND APPROVED BY HIM. | | THIS IS IN ADDITION TO THE LETTER FROM | | DESIGNER OF RECORD. | | | | 4)THE UPLIFT GIVEN ON THE TRUSS DRAWINGS | | EXCEEDS THE CAPACITIES OF THE CONNECTORS | | SPECIFIED IN THE SCHEDULE ON SHEET 6 OF | | THE PLANS FOR SEVERAL OF THE TRUSSES. | | T-21 @ 15= 1869# > A2 = 1060# | | T-7 @ 2= 3339# > A5 = 2650# | | T-8 @ 2= 2167# > A3 = 1300# | | T-9 @ 2= 2234# > A3 = 1300# | | T-3 @ 2&6= 1516# > A1 =755# | | T-32,T-33,T-26,T-27,T-28,ETC. | | PLEASE REVIEW TRUSS DRAWINGS AND | | CONNECTOR SCHEDULE AND MAKE CORRECTIONS | | AS NECESSARY. | | | | AN ADDITIONAL RESUB FEE WILL BE ASSESSED | | FOR SUBSEQUENT RESUBS. THERE WAS NO | | CHARGE FOR THE FIRST RESUB. SEE ATTACH- | | MENT. | | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL: | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)659-8096 EXT.8202 |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
5 |
Status |
F |
Date |
2002-02-01 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2002-02-01 |
Time |
11:26 |
Rev Time |
2.00 |
Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2002-02-01 00:00:00 | TRUSSES DENIED | | | | 1) SUBMIT REVISED PLANS AND CONNECTOR | | SCHEDULE AS INDICATED IN LETTER FROM | | THE ENGINEER. | | | | 2) TRUSS DRAWINGS CONTAIN INCORRECT | | DESIGN INFORMATION. IF TRUSSES ARE | | DESIGNED USING ASCE 7-95 THE CORRECT | | WIND SPEED TO USE IS 140 MPH. SEE MAP IN | | ASCE 7-95. IF USING 110 MPH WIND SPEED | | USE 1997 SBC SECTION 1606. | | | | 3) PROVIDE ENGINEERED DRAWINGS OF THE | | REPAIRS TO THE TRUSSES WITH DEFLECTIONS | | GREATER THAN L/360, AS INDICATED IN THE | | LETTER FROM MR. AVERKAMP. | | | | 4) PROVIDE THE TRUSS LAYOUT AND DRAWINGS | | TO THE DESIGNER OF RECORD FOR THE | | STRUCTURE FOR HIS REVIEW AND APPROVAL. | | THE DESIGNER OF RECORD OF THE STRUCTURE | | IS TO ACKNOWLEDGE HIS APPROVAL WITH HIS | | SIGNATURE AND DATE ON THE LAYOUT. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)659-8096 EXT.8202 |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
4 |
Status |
F |
Date |
2002-01-09 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2002-01-09 |
Time |
10:19 |
Rev Time |
2.00 |
Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2002-01-09 00:00:00 | TRUSSES DENIED | | | | 1) PROVIDE (2) SETS OF TRUSS DRAWINGS | | AND LAYOUTS. THE LAYOUTS ARE REQUIRED TO | | BE SIGNED, SEALED AND DATED BY THE TRUSS | | ENGINEER. THE ENGINEER'S TITLE BLOCK IS | | REQUIRED. INDICATE THE DESIGN CRITERIA | | USED ON THE LAYOUT. ASCE7-95 (140 MPH | | WINDLOAD) OR 97 SBC SECTION 1606 (110MPH | | WINDLOAD). | | | | 2) THE LAYOUT MUST BE REVIEWED AND | | APPROVED BY THE DESIGNER OF RECORD FOR | | THE STRUCTURE (JOHN AVERKAMP, INC.). | | THIS IS TO BE INDICATED ON THE TRUSS | | LAYOUT. | | | | 3) THE DESIGN CRITERIA INDICATED ON THE | | TRUSS DRAWINGS IS INCORRECT. THE CORRECT | | DESIGN CRITERIA IS ASCE7-95 (140 MPH | | WINDLOAD) OR 1997 STANDARD BUILDING CODE | | SECTION 1606 (110 MPH WINDLOAD). | | | | 4) THE TRUSS DRAWINGS ARE REQUIRED TO BE | | DATED BY THE TRUSS ENGINEER INDICATING | | THE DATE THEY WERE SEALED. | | | | 5) THE TRUSS LAYOUT AND THE ROOF FRAMING | | PLAN (SHEET 6) HAVE SIGNIFICANT | | DIFFERENCES. PLEASE SUBMIT A REVISED | | ROOF FRAMING PLAN. | | | | 6) TRUSS T1 (UPLIFT 1891#) EXCEEDS THE | | CAPACITY OF THE SPECIFIED CONNECTOR, A3 | | (1360#). PLEASE CORRECT. | | | | 7) T30 AT JOINT 10 (UPLIFT 912#) EXCEEDS | | CAPACITY OF A1 (755#). PLEASE CORRECT. | | | | 8) T32 (UPLIFTS 839# AND 1112#) EXCEED | | CAPACITY OF A1 (755#). PLEASE CORRECT. | | | | TO AVOID DELAYS, CHECK THE UPLIFT | | CAPACITIES OF THE SPECIFIED CONNECTORS | | TO ENSURE THAT THEY ARE CAPABLE OF | | RESISTING THE IMPOSED LOADS. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)659-8096 EXT.8202 |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
3 |
Status |
P |
Date |
2001-11-20 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2001-11-20 |
Time |
09:46 |
Rev Time |
1.00 |
Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-11-20 00:00:00 | REVISION TO ADD COVERED PORCH IS OK | | 11-20-01 RM |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
P |
Date |
2001-10-11 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2001-10-11 |
Time |
13:45 |
Rev Time |
2.00 |
Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2001-09-12 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2001-09-12 |
Time |
14:04 |
Rev Time |
4.00 |
Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-09-12 00:00:00 | *************BUILDING UNSAT************* | | | | 1) A RECORDED COPY OF THE NOTICE OF | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | PERMIT CAN BE ISSUED. | | | | 2) IMPACT FEES MUST BE PAID TO PALM | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | COPY OF RECEIPT SUBMITTED TO CITY OF | | WEST PALM BEACH BUILDING DEPARTMENT, | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | 3) PROVIDE ENERGY CALCULATIONS THAT HAVE | | SIGNATURE OF OWNER/AGENT. | | | | 4)PROVIDE (2) CURRENT AND COMPLETE | | COPIES OF SBCCI OR METRO-DADE PRODUCT | | APPROVALS FOR: | | - FIXED GLASS (ARCHED TOP) | | - STRUCTURAL MULLIONS | | - EXTERIOR OUTSWING DOUBLE DOORS | | - SLIDING GLASS DOORS | | | | 5) PROVIDE KEY PLAN AND INSTALLATION | | SCHEDULE FOR STORM PANELS. INDICATE | | TYPE OF ANCHORS THAT WILL BE USED. | | | | 6) THE INFORMATION PROVIDED FOR THE | | EMERGENCY EGRESS WINDOWS CONTAINS ERRORS | | THERE ARE NO SECTIONS 1005.42, 1005A2 OR | | 1005.43 IN THE 1997 SBC. THE CODE DOES | | NOT SPECIFY A MINIMUM TOTAL GLASS AREA. | | ONLY THE MINIMUM NET CLEAR OPENING AREA | | AND MINIMUM NET CLEAR OPENING DIMENSIONS | | ARE SPECIFIED. PLEASE CORRECT. (SHEET 1) | | | | 7) THERE IS NO STEEL REINFORCEMENT | | INDICATED FOR THE 8" THICKENED FOOTER AT | | THE GARAGE. PLEASE INDICATE ON PLANS. | | (SHEET2) | | | | 8) THE WALL BETWEEN THE HOUSE AND THE | | GARAGE IS REQUIRED TO BE INSULATED AND | | THE DOOR IN THIS WALL MUST BE SOLID CORE | | WOOD, WOOD PANEL OR INSULATED DOOR PER | | 97 FLORIDA ENERGY CODE. PLEASE INDICATE | | THIS ON PLANS. | | | | 9) PLEASE INDICATE THE MEAN ROOF HEIGHT | | ON THE PLANS. | | | | 10) THE MINIMUM BUILDING FLOOR ELEVATION | | AT HABITABLE AREAS SHALL BE A MINIMUM OF | | 4 INCHES ABOVE FINISH GRADE AND THE | | BOTTOM OF THE FOOTER SHALL BE A MINIMUM | | OF 12 INCHES BELOW FINISH GRADE. PLEASE | | INDICATE THIS ON THE PLANS. (SHEET 7) | | | | 11) THE GIRDER TRUSS AT BEDROOM 3 AND | | THE FAMILY ROOM WITH AN UPLIFT GIVEN OF | | 4700# HAS ONE A5 ANCHOR INDICATED WHICH | | IS ONLY GOOD FOR 1815# OF UPLIFT. PLEASE | | CORRECT. (SHEET 6) | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)659-8096 EXT.8202 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2001-11-19 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2001-11-19 |
Time |
15:20 |
Rev Time |
0.25 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2001-08-15 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2001-08-15 |
Time |
15:50 |
Rev Time |
0.25 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|