Plan Review Details - Permit 01080506
Plan Review Stops For Permit 01080506
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-08-29 Cont ID  
Sent By dpalmer Date 2001-08-29 Time 18:59 Rev Time 0.00
Received By dpalmer Date 2001-08-29 Time 18:59 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2001-08-28 Cont ID  
Sent By mcarsill Date 2001-08-28 Time 16:39 Rev Time 0.00
Received By mcarsill Date 2001-08-28 Time 16:39 Sent To  
Notes
2001-08-28 00:00:001) WET FIRE HYDRANTS ARE REQUIRED PRIOR
 TO,DURING AND AFTER CONSTRUCTION.
 2) BUILDING ADDRESSES REQUIRED.
 3) ELECTRIC POWERED SMOKE DETECTORS
 REQUIRED. WHEN ACTIVATED, THESE DEVICES
 ARE TO BE AUDIBLE IN THE SLEEPING ROOMS
 OF THAT UNIT.
 4) PORTABLE FIRE EXTINGUISHERS REQUIRED.
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-11-15 Cont ID  
Sent By ndenmark Date 2001-11-15 Time 14:11 Rev Time 0.50
Received By ndenmark Date 2001-11-15 Time 14:11 Sent To  
Notes
2001-11-15 00:00:00REVISION DATED 11/15/01

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-08-16 Cont ID  
Sent By hmoser Date 2001-08-16 Time 19:02 Rev Time 0.33
Received By hmoser Date 2001-08-16 Time 19:02 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2001-08-25 Cont ID  
Sent By jleech Date 2001-08-25 Time 08:26 Rev Time 1.00
Received By jleech Date 2001-08-25 Time 08:26 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2001-10-22 Cont ID  
Sent By jgomez Date 2001-10-22 Time 12:10 Rev Time 0.25
Received By jgomez Date 2001-10-22 Time 12:10 Sent To  
Notes
2001-10-22 00:00:00TRUSS DRAWINGS REVIEW.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2001-10-11 Cont ID  
Sent By jgomez Date 2001-10-11 Time 11:54 Rev Time 0.33
Received By jgomez Date 2001-10-11 Time 11:53 Sent To  
Notes
2001-10-11 00:00:00TRUSS DRAWINGS CHECKLIST:
 1-UPDATE GENERAL TRUSS DETAILS WITH
 LEGIBLE DRAWINGS AND UPDATED CODES.
 2-ONLY ONE ENGINEER TO SIGN AND SEAL THE
 ENGINEERED TRUSSES OR PROVIDE THE
 INFORMATION REQUIRED BY FL. STATUTES
 WHEN CHANGING THE ENGINEER.
 3-ARCHITECT TO SPECIFY UPLIFT CONNECTOR
 FOR TRUSSES S15 AT THE MIDPOINT
 BEARING AREA.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2001-09-05 Cont ID  
Sent By jgomez Date 2001-09-05 Time 16:44 Rev Time 1.00
Received By jgomez Date 2001-09-05 Time 16:44 Sent To  
Notes
2001-09-05 00:00:00APPROVED WITH PROVISO:
 1-FLOOD ZONE A0. WILL NEED TO PROVIDE
 THE ELEVATION CERTIFICATE.
 2-SURVEY SHOW TWO STORY TOWNHOUSE FOR
 LOT 123. REVISE AS REQUIRED.
 3-REVISE THE DESIGN CERTIFICATION FOR
 BUILDING CODE COMPLIANCE FORM.
 -THE MEAN ROOF HEIGHT IS INCORRECT.
 MEAN ROOF HEIGHT IS TAKEN FROM THE
 FINISH GRADE, NOT FROM THE FIN. FL,
 TO THE AVERAGE POINT OF THE HIGHEST
 ROOF. THEREFORE, MEAN ROOF HEIGHT IS
 +/- 15'-6" SEE EXTERIOR ELEVATIONS.
 -ALSO, REVISE THE BASIC VELOCITY
 PRESSURE ACCORDINGLY. SEE TABLE
 1606.2A SBC 1997.
 4-ENERGY CALCULATIONS SHOW MULTIFAMILY
 FOR 5 UNITS. THIS BUILDING HAS ONLY
 THREE. REVISE AS REQUIRED.
 -ALSO REVISE THE #OF BEDROOMS ACOORDING
 TO THE OPTIONS SELECTED.
 5-PROVIDE ACTUAL DADE COUNTY PRODUCT
 APPROVAL FOR STRUCTURAL WINDOW MULLION
 6-REVISE SHEET SH-1. GLASS BLOCK TO BE
 USED SHALL HAVE 2 HOUR FIRE RATING AT
 2 HR WALL SEPARATION BET. TOWNHOUSES,
 NOT 3/4 HR.
  
  
 NOTES:
 -DRAWINGS TO BE FILED UNDER PERMIT #
 01080506.
 -THESE COMMENTS APPLY TO PERMIT #S:
 01080506, 01080498 AND 01080507.

Review Stop Z ZONING
Rev No 1 Status P Date 2001-08-17 Cont ID  
Sent By sgraham Date 2001-08-17 Time 15:44 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***