|
 |
 |
 |
 |
 |
Plan Review Details - Permit 01080506
Plan Review Stops For Permit 01080506 |
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2001-08-29 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-08-29 |
Time |
18:59 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-08-29 |
Time |
18:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2001-08-28 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2001-08-28 |
Time |
16:39 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2001-08-28 |
Time |
16:39 |
Sent To |
|
|
Notes |
2001-08-28 00:00:00 | 1) WET FIRE HYDRANTS ARE REQUIRED PRIOR | | TO,DURING AND AFTER CONSTRUCTION. | | 2) BUILDING ADDRESSES REQUIRED. | | 3) ELECTRIC POWERED SMOKE DETECTORS | | REQUIRED. WHEN ACTIVATED, THESE DEVICES | | ARE TO BE AUDIBLE IN THE SLEEPING ROOMS | | OF THAT UNIT. | | 4) PORTABLE FIRE EXTINGUISHERS REQUIRED. | | | | MIKE CARSILLO, CAPTAIN | | 659-8096,EXT.8497 | | 835-2910 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2001-11-15 |
|
|
Cont ID |
|
Sent By |
ndenmark |
Date |
2001-11-15 |
Time |
14:11 |
Rev Time |
0.50 |
Received By |
ndenmark |
Date |
2001-11-15 |
Time |
14:11 |
Sent To |
|
|
Notes |
2001-11-15 00:00:00 | REVISION DATED 11/15/01 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2001-08-16 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2001-08-16 |
Time |
19:02 |
Rev Time |
0.33 |
Received By |
hmoser |
Date |
2001-08-16 |
Time |
19:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2001-08-25 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2001-08-25 |
Time |
08:26 |
Rev Time |
1.00 |
Received By |
jleech |
Date |
2001-08-25 |
Time |
08:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
3 |
Status |
P |
Date |
2001-10-22 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2001-10-22 |
Time |
12:10 |
Rev Time |
0.25 |
Received By |
jgomez |
Date |
2001-10-22 |
Time |
12:10 |
Sent To |
|
|
Notes |
2001-10-22 00:00:00 | TRUSS DRAWINGS REVIEW. |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
F |
Date |
2001-10-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2001-10-11 |
Time |
11:54 |
Rev Time |
0.33 |
Received By |
jgomez |
Date |
2001-10-11 |
Time |
11:53 |
Sent To |
|
|
Notes |
2001-10-11 00:00:00 | TRUSS DRAWINGS CHECKLIST: | | 1-UPDATE GENERAL TRUSS DETAILS WITH | | LEGIBLE DRAWINGS AND UPDATED CODES. | | 2-ONLY ONE ENGINEER TO SIGN AND SEAL THE | | ENGINEERED TRUSSES OR PROVIDE THE | | INFORMATION REQUIRED BY FL. STATUTES | | WHEN CHANGING THE ENGINEER. | | 3-ARCHITECT TO SPECIFY UPLIFT CONNECTOR | | FOR TRUSSES S15 AT THE MIDPOINT | | BEARING AREA. |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
P |
Date |
2001-09-05 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2001-09-05 |
Time |
16:44 |
Rev Time |
1.00 |
Received By |
jgomez |
Date |
2001-09-05 |
Time |
16:44 |
Sent To |
|
|
Notes |
2001-09-05 00:00:00 | APPROVED WITH PROVISO: | | 1-FLOOD ZONE A0. WILL NEED TO PROVIDE | | THE ELEVATION CERTIFICATE. | | 2-SURVEY SHOW TWO STORY TOWNHOUSE FOR | | LOT 123. REVISE AS REQUIRED. | | 3-REVISE THE DESIGN CERTIFICATION FOR | | BUILDING CODE COMPLIANCE FORM. | | -THE MEAN ROOF HEIGHT IS INCORRECT. | | MEAN ROOF HEIGHT IS TAKEN FROM THE | | FINISH GRADE, NOT FROM THE FIN. FL, | | TO THE AVERAGE POINT OF THE HIGHEST | | ROOF. THEREFORE, MEAN ROOF HEIGHT IS | | +/- 15'-6" SEE EXTERIOR ELEVATIONS. | | -ALSO, REVISE THE BASIC VELOCITY | | PRESSURE ACCORDINGLY. SEE TABLE | | 1606.2A SBC 1997. | | 4-ENERGY CALCULATIONS SHOW MULTIFAMILY | | FOR 5 UNITS. THIS BUILDING HAS ONLY | | THREE. REVISE AS REQUIRED. | | -ALSO REVISE THE #OF BEDROOMS ACOORDING | | TO THE OPTIONS SELECTED. | | 5-PROVIDE ACTUAL DADE COUNTY PRODUCT | | APPROVAL FOR STRUCTURAL WINDOW MULLION | | 6-REVISE SHEET SH-1. GLASS BLOCK TO BE | | USED SHALL HAVE 2 HOUR FIRE RATING AT | | 2 HR WALL SEPARATION BET. TOWNHOUSES, | | NOT 3/4 HR. | | | | | | NOTES: | | -DRAWINGS TO BE FILED UNDER PERMIT # | | 01080506. | | -THESE COMMENTS APPLY TO PERMIT #S: | | 01080506, 01080498 AND 01080507. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2001-08-17 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2001-08-17 |
Time |
15:44 |
Rev Time |
0.25 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |