Plan Review Stops For Permit 01080364 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2001-12-27 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2001-12-27 |
Time |
16:18 |
Rev Time |
1.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-12-27 00:00:00 | REVISION DATED 10/18/01JW |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2001-10-16 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2001-10-16 |
Time |
07:55 |
Rev Time |
2.00 |
Received By |
jwitmer |
Date |
2001-10-16 |
Time |
07:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2001-09-14 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2001-09-14 |
Time |
14:51 |
Rev Time |
3.00 |
Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-09-14 00:00:00 | | | BUILDING COMMENTS | | ----------------- | | | | 1] | | SHOWER SHALL COMPY WITH ACCESSIBILITY | | REQUIREMENTS, SEE 4.21 FAC. | | 2] | | FOOTING DETAILS SHOW 3 BARS, AND THE | | NOTE ONLY CALLS FOR 2? | | BOTTOM OF FOOTINGS SHALL BE MINIMUM 12" | | BELOW GRADE. | | 3] | | THE WEST ELEVATION WALL SHALL NOT HAVE | | ANY OPENINGS PER TABLE 600 SBC, 0-3FT. | | ALSO SEE 705 SBC FOR PROTECTED OPENINGS | | WHEN IF EXTERIOR WALLS ARE LESS THAN | | 15FT. FROM P/L. | | 4] | | CASEMENT WINDOWS SHALL NOT OPEN OVER | | PUBLIC PROPERTY AT NORTH ELEVATION. | | 5] | | PROVIDE COMPLETED FLA. ENERGY EFF. | | REPOTS. | | 6] | | SUBMIT PRODUCT TESTING FOR ALL EXTERIOR | | WINDOWS AND DOORS, WIND COMPLIANCE AND | | IMPACT RESISTANCE FOR GLAZING. SUBMIT | | TEST REPORT FOR ROOF COVERS. | | 7] | | SHOW ACCESSIBLE ROUTE FROM PARKING | | SPACE TO THE MAIN ENTRANCE, GATES SHALL | | BE ACCESSIBLE TYPE. | | 8] | | P.B.C COUNTY IMPACT FEES AND CITY RADON | | FEES ARE DUE. | | | | | | REVIEWED BY: | | LUIS MARTINEZ | | 659-8096 | | #8456 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2001-10-10 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-10-10 |
Time |
21:03 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-10-10 |
Time |
21:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2001-08-28 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-08-28 |
Time |
19:02 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-08-28 |
Time |
19:02 |
Sent To |
|
|
Notes |
2001-08-28 00:00:00 | *************** UNSAT ************** | | | | 1)NOTE: PLEASE NOTE THAT PANEL SCHEDULE | | IS SHOWING ALL 2-POLE BRKRS ON LEFT AND | | RIGHT OF PANEL ON THE SAME PHASE. PLEASE | | CORRECT. ALL 2POLE BRKRS SHOULD LINE UP | | ON SAME SIZE FOR 220V | | | | 2)NOTE: PLEASE NOTE LOAD FOR WATER HEAT- | | -ER NEEDS TO CORRELATE W/ LOAD SHOWN ON | | PANEL SCHEDULE. | | | | 3)NOTE: PLEASE NOTE THAT RISER DIAGRAM | | IS MISSING RISER SIZE, WIRE SIZE FROM | | RISER TO METER TO MAIN DISCONNECT. | | | | 4)NOTE: PLEASE ALSO NOTE THAT PLANS SHOW | | MAIN DISCONNECT AND A MCB PANEL. PLEASE | | NOTE PANEL MAY HAVE MAIN ALSO BUT IS NOT | | REQUIRED W/ MAIN DISCONNECT OUTSIDE. | | | | 5)NOTE: PLEASE NOTE ALL CONTINOUS LOADS | | TO BE SHOWN AT 125%. (LIGHTING) ETC. | | PER 230-42/215-3 | | | | 6)NOTE: PLEASE NOTE LOAD SHOWN FOR WATER | | HEATER AT 1500 WATTS AND 20KW ?? WHICH | | ONE? PLEASE ALSO NOTE THAT IF 1500WATTS | | THEM THE MAX OCP IS AT 150%. YOU SHOW | | A 2-P-30. PLEASE CORRECT | | | | 7) NOTE: PLEASE SHOW GROUNDING ELECTRODE | | GOING TO BUILDING STEEL AND COLD WATER | | PER 250-50. SHOWS CWP, NOT BLDG STEEL. | | | | 8)NOTE: PLEASE NOTE THAT PLANS NEED TO | | SHOW ALL BRANCH CIRCUIT #`S ON PLANS | | AND CORRELATE WITH SUBMITTED PANEL | | SCHEDULES.215-5 | | | | 9)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | ALL NEW EQUIPMENT BEING INSTALLED. | | MAINS/PANELS/BREAKERS MUST BE RATED FOR | | THE AVAILABLE FAULT CURRENT PER 110-9. | | PLEASE NOTE THAT AIC RATING IS SHOWN FOR | | PANEL, BUT NOT FOR MAIN. PLEASE SUBMIT | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
3 |
Status |
P |
Date |
2001-12-27 |
|
|
Cont ID |
|
Sent By |
mamini |
Date |
2001-12-27 |
Time |
16:41 |
Rev Time |
1.00 |
Received By |
mamini |
Date |
2001-12-27 |
Time |
16:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
P |
Date |
2001-09-28 |
|
|
Cont ID |
|
Sent By |
mamini |
Date |
2001-09-28 |
Time |
08:31 |
Rev Time |
3.00 |
Received By |
mamini |
Date |
2001-09-28 |
Time |
08:31 |
Sent To |
|
|
Notes |
2001-09-28 00:00:00 | PASSED : | | 1. RESPONSES TO THE PREVIOUS REVIEW | | COMMENTS DATED 8-10-01 STISFACTORY, | | PLANS REVISED PER REVIEW COMMENTS. | | | | IF ANY QUESTIONS PLEASE CONTACT 659-8096 | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2001-08-10 |
|
|
Cont ID |
|
Sent By |
mamini |
Date |
2001-08-10 |
Time |
09:37 |
Rev Time |
5.00 |
Received By |
mamini |
Date |
2001-08-10 |
Time |
08:49 |
Sent To |
|
|
Notes |
2001-08-10 00:00:00 | FAILED: | | 1. PLEASE PROVIDE A MINIMUM OF 12'-6" | | CLEAR OPENING BETWEEN THE GATE POSTS FOR | | THE PROPOSED DUMPSTER, IF GARBAGE IS TO | | BE PICKED UP BY THE CITY. | | 2. ALL OFF-STREET PARKING STALLS MUST BE | | PAINTED WITH DOUBLE 4" WIDE WHITE STRIPE | | PER CITY REQUIREMENT. | | 3. SHEET C.1 OF 2 SHOWS GRASSED AREA IN | | FRONT OF DRIVEWAY TO DATURA STREET, | | PLEASE VERIFY. | | 4. ALL DRIVEWAY THAT WILL NOT BE USED | | MUST BE REMOVED AND REPLACED WITH THE | | REGULAR CURBS( & GUTTERS). | | 5. PLEASE VERIFY THE DETAILS SHOWN FOR | | THE TYPE "C" INLET, SHEET C.2 OF 2. | | 6. SHEET C.1 OF 2, NOTES; NO. 2 NOTES | | REFERS TO EXISTING WATER AND SEWER TO BE | | USED, HOWEVER NO PLANS OR DETAILS HAVE | | BEEN PROVIDED, PLEASE NOTE THAT PLANS | | WHICH INCLUDES DETAILS, MAT'L, SIZE AND | | CLEARANCES/CONFLICTS, LOCATIONS OF | | CONNECTIONS AND BACKFLOW PREVENTERS MUST | | BE SUBMITTED FOR OUR REVIEW AND APPROVAL | | 7. ANY NEW CONNECTIONS TO CITY SERVICES | | WILL REQUIRE A SEPARATE PERMIT FROM | | PUBLIC UTILITIES ENGINEERING SERVICES | | DEPARTMENT, 659-8040. | | 8. ANY WORK WITHIN PUBLIC R.O.W WILL | | REQUIRE A SEPARATE PERMIT FROM CITY | | ENGINEERS OFFICE 659-8040 | | 9. PLEASE PROVIDE PERVIOUS & IMPERVIOUS | | CALCULATIONS FOR ENTIRE SITE. | | | | IF ANY QUESTIONS PLEASE CONTACT 659-8096 | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2001-09-26 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2001-09-26 |
Time |
17:29 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2001-09-26 |
Time |
17:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2001-08-09 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2001-08-09 |
Time |
08:41 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2001-08-09 |
Time |
08:41 |
Sent To |
|
|
Notes |
2001-08-09 00:00:00 | 1) PLEASE BE ADVISED THAT THIS LOCATION | | IS LOCATED WITHIN THE CITY FIRE LIMITS. | | CERTAIN RESTRICTIONS APPLY WITHIN | | THESE FIRE LIMITS. COMPLAINCE WITH | | APPENDIX F OF THE STANDARD BUILDING | | CODE, 1997 EDITION. PLEASE INDICATE | | COMPLIANCE. | | 2) BUILDING ADDRESS REQUIRED PER CITY | | CODE REQUIREMENTS 3343-00. | | 3) DUCT SMOKE DETECTORS ARE REQUIRED IN | | HVAC SYSTEMS OVER 2000 CFM. | | 4) PLEASE PROVIDE INTERIOR FINISH | | CLASSIFICATION INFORMATION FOR WALLS | | AND CEILINGS. | | 5) CANOPIES ARE TO BE FIRE RETARDANT. | | | | MIKE CARSILLO, CAPTAIN | | 659-8096,EXT.8497 | | 835-2910 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2002-02-19 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2002-02-19 |
Time |
12:53 |
Rev Time |
0.45 |
Received By |
pkrauss |
Date |
2002-02-19 |
Time |
12:19 |
Sent To |
|
|
Notes |
2002-02-19 00:00:00 | MECHANICAL PERMIT 010801365 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2001-10-29 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2001-10-29 |
Time |
10:36 |
Rev Time |
0.40 |
Received By |
pkrauss |
Date |
2001-10-29 |
Time |
10:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2001-10-13 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2001-10-13 |
Time |
07:42 |
Rev Time |
0.40 |
Received By |
pkrauss |
Date |
2001-10-13 |
Time |
07:35 |
Sent To |
|
|
Notes |
2001-10-13 00:00:00 | *******************DENIED*************** | | | | | | 1.AHU #2 INDICATES A FIRE DAMPER ON | | THE O.A. DUCT PENETRATING THE AHU | | CLOSET.IS THE CLOSET RATED? | | | | 2.NO COMBUSTIBLES ABOVE THE CEILING | | IN THE RETURN AIR PLENUM. | | | | THE FOLLOWING COMMENTS FROM REVIEW DATED | | 8-21-01 WERE NEVER ADDRESSED. | | | | 1. CLARIFICATION OF CONDENSATE DRAINS. | | | | 2. DUCT SMOKE DETECTORS TIED TO ALARM/ | | STROBE. | | | | 3. AIR BALANCE SCHEDULE SHOWING | | COMPLIANCE WITH 1997 SMC 501.2. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT 659-8096 EXT. | | 8388. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2001-08-21 |
|
|
Cont ID |
|
Sent By |
ndenmark |
Date |
2001-08-21 |
Time |
12:54 |
Rev Time |
0.33 |
Received By |
ndenmark |
Date |
2001-08-21 |
Time |
12:54 |
Sent To |
|
|
Notes |
2001-08-21 00:00:00 | *******************DENIED*************** | | | | 1. PROVIDE OUTSIDE AIR CALCULATIONS PER | | ASHRAE 62.89 | | 2. PROVIDE AIR BALANCE SCHEDULE SHOWING | | COMPLIANCE WITH 1997 SMC 501.2 | | 3. BATHROOM EXHAUST FANS NEED MORE | | INFORMATION, INCLUDING CFM. | | 4. NO CFM SHOWN AT A/C DROP IN WOMEN'S | | BATHROOM | | 5. DUCT SMOKE DETECTORS WITH | | NOTIFICATION TO BUILDING FIRE ALARM OR | | HORN AND STROBE IF NO BLDG FIRE ALARM | | SYSTEM REQUIRED FOR BOTH AHUS. | | 6. PLEASE CLARIFY THE CONDENSATE DRAINS. | | PRIMARY IS NOT SHOWN ON PLAN AND | | EMERGENCY DRAIN NEEDS TO TERMINATE IN | | CONSPICUOUS LOCATION. | | IF CONDENSATE FOR AHU ZONE 2 TERMINATES | | ON WEST SIDE OF BUILDING AS SHOWN,IS | | THERE A PERVIOUS AREA ON THIS PROPERTY | | FOR THE DRAIN TO RUN TO? | | CONDENSATE SHALL EITHER TERMINATE IN A | | STORM SEWER OR APPROVED DRYWELL. | | 7. CONDENSING UNITS ARE TO BE ON SOLID | | CONCRETE PADS MINIMUM 3" ABOVE | | ADJOINING GRADE. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
P |
Date |
2001-12-29 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2001-12-29 |
Time |
06:57 |
Rev Time |
0.50 |
Received By |
jleech |
Date |
2001-12-29 |
Time |
06:57 |
Sent To |
|
|
Notes |
2001-12-29 00:00:00 | REVISION; | | RAIN LEADER CALCULATIONS. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2001-11-21 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
2001-11-21 |
Time |
08:54 |
Rev Time |
1.00 |
Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-11-21 00:00:00 | PROVISO: SPECIAL EXECPTION BBCA. REST/RM | | PES. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2001-11-21 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2001-10-29 |
Time |
15:56 |
Rev Time |
1.00 |
Received By |
pschmitz |
Date |
2001-10-29 |
Time |
15:56 |
Sent To |
|
|
Notes |
2001-10-29 00:00:00 | SEPARATE PERMIT REQUIRED FOR PLUMBING. | | CALCULATIONS FOR MINIMUM FACILITIES ARE | | REQUIRED FOR PLBG PERMIT. NOT ENOUGH W/C | | AND LAV. ON PLANS ATT. | | | | KEN STEVENS |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2001-10-12 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2001-10-12 |
Time |
16:30 |
Rev Time |
1.00 |
Received By |
kstevens |
Date |
2001-10-12 |
Time |
16:30 |
Sent To |
|
|
Notes |
2001-10-12 00:00:00 | DENIED | | REFERENCE: SPC-94 - FACBC-97 | | | | 1) VARIANCE NOT APPROVED. SPC-97 NOT | | ADOPTED IN PALM BEACH COUNTY. PLEASE | | SUBMIT CALCULATIONS FOR MINIMUM FACILIT- | | IES PER SPC-94 TABLE 407. | | | | 2) WATER HAMMER ARRESTORS TO BE PLACED | | NEAR SOURCE NOT AT TOP OF DROPS PER | | MANUFACTURES INSTALLATION INSTRUCTIONS | | AND WH-PDI 201. | | | | 3) PAGE A.3 DOOR SHALL NOT OPEN INTO | | CLEAR FLOOR SPACE PER FACBC-9 SEC 4.22.2 | | DOORS TO HDCP BATHROOMS SHALL OPEN OUT. | | | | REVIEW BY KEN STEVENS | | (561) 569-8096 EXT. 8377 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2001-08-23 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2001-08-23 |
Time |
10:36 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2001-08-23 |
Time |
10:36 |
Sent To |
|
|
Notes |
2001-08-23 00:00:00 | DENIED | | | | 1) MORE FIXTURES REQUIRED. PLEASE SUBMIT | | CALCULATIONS FOR MINIMUM FIXTURES REQ- | | UIRED FOR WATER CLOSETS AND LAVS. PER | | SPC-94 TABLE 407. | | | | 2) WATER HEATER TO BE READILY ACCESSABLE | | PER SPC-94 SEC. 501.7. PLEASE SHOW DE- | | TAILS. | | | | 3) WATER HAMMER ARRESTORS TO BE INSTALL- | | ED PER MANUFACTURE'S INSTALLATION INSTR- | | UCTIONS AND PDI WH 201. | | | | 4) PLEASE SUBMIT CALCULATIONS FOR ROOF | | DOWN SPOUTS AND OVERFLOW SCUPPERS USING | | CHAPTER 11 SPC-94 SECTIONS 1108 AND 1109 | | | | REVIEW BY KEN STEVENS | | (561) 569-8096 EXT. 8377 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2001-09-28 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2001-09-28 |
Time |
08:46 |
Rev Time |
0.25 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|