Plan Review Details - Permit 01080230
Plan Review Stops For Permit 01080230
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2001-08-29 Cont ID  
Sent By dpalmer Date 2001-08-29 Time 20:43 Rev Time 0.00
Received By dpalmer Date 2001-08-29 Time 20:43 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-08-20 Cont ID  
Sent By dpalmer Date 2001-08-20 Time 21:28 Rev Time 0.00
Received By dpalmer Date 2001-08-20 Time 21:28 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2001-09-28 Cont ID  
Sent By pkrauss Date 2001-09-28 Time 09:18 Rev Time 0.40
Received By pkrauss Date 2001-09-28 Time 09:18 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2001-09-04 Cont ID  
Sent By ndenmark Date 2001-09-04 Time 10:14 Rev Time 0.33
Received By ndenmark Date 2001-09-04 Time 10:14 Sent To  
Notes
2001-09-04 00:00:00DENIED
 1. PROVIDE DUCT AND DROP SIZES AND CFM
 INFORMATION FOR ADDITIONAL AIR
 CONDITIONING. PROVIDE LOCATION OF DROPS
 AND THE TIE IN TO EXISTING SYSTEM.
 2. PROVIDE DRYEREXHAUST DUCT
 INFORMATIONINCLUDING TERMINATION
 LOCATION.
 3. PROVIDE INFORMATION ON BATHROOM
 EXHAUST FAN DUCT INCLUDING TERMINATION
 LOCATION.
 1997 MODEL COUNTYWIDE AMENDMENTS AS
 AMENDED TO THE STANDARD CODES 104.2
 REQUIRES PLANS TO BE OF SUFFICIENT
 CLARITY AND DETAILS TO INDICATE THE
 NATURE OF THE WORK.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2001-08-20 Cont ID  
Sent By pkrauss Date 2001-08-20 Time 10:51 Rev Time 0.40
Received By pkrauss Date 2001-08-20 Time 10:48 Sent To  
Notes
2001-08-20 00:00:00*******************DENIED***************
  
  
 INSUFFICIENT INFORMATION FOR MECHANICAL
 REVIEW.PLEASE PROVIDE PLANS WITH
 MECHANICAL PERMIT APPLICATION.
  
  
 SHOULD EXISTING AC SYSTEM BE INTENDED TO
 SUPPLY ADDITION WITH AIR/HEAT PLEASE
 PROVIDE EQUIPMENT INFORMATION AS WELL
 AS SQUARE FOOTAGE (TOTAL) THE SYSTEM
 WILL BE REQUIRED TO SUPPLY.
  
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT
 PATTY KRAUSS AT 659-8096 EXT. 8388.

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-08-25 Cont ID  
Sent By jleech Date 2001-08-25 Time 10:27 Rev Time 0.33
Received By jleech Date 2001-08-25 Time 10:27 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-08-14 Cont ID  
Sent By kstevens Date 2001-08-14 Time 09:44 Rev Time 0.50
Received By kstevens Date 2001-08-14 Time 09:44 Sent To  
Notes
2001-08-14 00:00:00DENIED
  
 MINIMUM FACILITIES REQUIRE A WASHING
 MACHINE CONNECTION IN EACH DWELLING.
 REMOVING WASH MACHINE CONNECTION NOT
 APPROVED PER SPC-94 TABLE 407
  
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT. 8377

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2001-09-04 Cont ID  
Sent By lsmith Date 2001-09-04 Time 14:28 Rev Time 0.75
Received By lsmith Date   Time   Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2001-08-21 Cont ID  
Sent By lsmith Date 2001-08-21 Time 07:13 Rev Time 1.00
Received By lsmith Date   Time   Sent To  
Notes
2001-08-21 00:00:00*************BUILDING UNSAT*************
  
 SBC 104.2.2
  
 1. PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
  
 2. BEFORE A PERMIT TO CONSTRUCT CAN BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH CO.,THE PERMIT PLANS STAMPED BY
 THEM AND THE RECEIPT ATTACHED TO THE
 PERMIT APPLICATION.
  
 IF ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BLDG. PLANS EXAMINER
 659-8096 EXT: 8394

Review Stop Z ZONING
Rev No 1 Status P Date 2001-08-07 Cont ID  
Sent By sgraham Date 2001-08-07 Time 16:02 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***