Plan Review Details - Permit 01071419
Plan Review Stops For Permit 01071419
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-02-07 Cont ID  
Sent By btrobaug Date 2002-02-07 Time 14:02 Rev Time 0.00
Received By btrobaug Date 2002-02-07 Time 13:58 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-08-20 Cont ID  
Sent By dpalmer Date 2001-08-20 Time 20:27 Rev Time 0.00
Received By dpalmer Date 2001-08-20 Time 20:27 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2001-08-21 Cont ID  
Sent By mcarsill Date 2001-08-21 Time 12:52 Rev Time 0.00
Received By mcarsill Date 2001-08-21 Time 12:52 Sent To  
Notes
2001-08-21 00:00:001) BUILDING ADDRESSES REQUIRED.
 2) WET FIRE HYDRANTS ARE REQUIRED PRIOR
 TO,DURING AND AFTER CONSTRUCTION.
 3) ELECTRIC POWERED SMOKE DETECTORS ARE
 REQUIRED. WHEN ACTIVATED, THESE DEVICES
 ARE TO BE AUDIBLE IN THE SLEEPING ROOMS
 OF THAT UNIT.
 4) PORTABLE FIRE EXTINGUISHERS ARE
 REQUIRED.
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2002-01-10 Cont ID  
Sent By pkrauss Date 2002-01-10 Time 10:21 Rev Time 0.35
Received By pkrauss Date 2002-01-10 Time 10:16 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-09-10 Cont ID  
Sent By pkrauss Date 2001-09-10 Time 13:55 Rev Time 0.30
Received By pkrauss Date 2001-09-10 Time 13:55 Sent To  
Notes
2001-09-10 00:00:00******************PROVISO***************
  
  
 MECH PERMIT 01071450
  
 R/A SHALL NOT BE IN MASTER BEDROOM
 CLOSET.SHOULD BE EITHER DUCTED FROM
 BEDROOM AREA TO AHU OR TRANSFER AIR
 DUCT FROM BEDROOM TO LIVING ROOM.
 1997 SMC 503.3.1.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT
 PATTY KRAUSS AT 659-8096 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2001-08-15 Cont ID  
Sent By hmoser Date 2001-08-15 Time 17:47 Rev Time 0.33
Received By hmoser Date 2001-08-15 Time 17:47 Sent To  
Notes
2001-08-15 00:00:00PLAN DENIED
 #1 NO MECHANICAL PLANS
 #2 NO ENERGY CALC.
 PLAN REVIEW BY HAROLD MOSER
 [561]659-8096 EXT.8390

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-09-18 Cont ID  
Sent By kstevens Date 2001-09-18 Time 12:28 Rev Time 0.33
Received By kstevens Date 2001-09-18 Time 12:28 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-08-13 Cont ID  
Sent By kstevens Date 2001-08-13 Time 11:29 Rev Time 1.00
Received By kstevens Date 2001-08-13 Time 11:29 Sent To  
Notes
2001-08-13 00:00:00DENIED
  
 1) PAGES 1A & 2 GENERAL NOTES #11 CHANGE
 TO READ FHA 1998 DESIGN MANUAL.
  
 2) MODEL 1527 (L) & (R), M/B SHOWS 1'7"
 TO CENTER OF W/C, AND IT SHOULD BE 1'6"
 ALSO SHOW CLEAR FLOOR SPACE FOR LAV.
 PAGES 1A & 1B
  
 3) IN BATH 2 SHOW CLEAR FLOOR SPACE FOR
 W/C AND LAV. PAGES 1A & 1B.
  
 4) MODEL 1409 (L) & (R), M/B SHOWS 1'7"
 TO CENTER OF W/C, AND IT SHOULD BE 1'6"
 ALSO SHOW CLEAR FLOOR SPACE FOR LAV.
 PAGES 1A & 1B.
  
 5) BATH 2 SHOWS 2'8" OPENING FOR W/C.
 2'9" MINIMUM SPACE REQUIRED FOR W/C.
 ALSO SHOW CLEAR FLOOR SPACE FOR W/C AND
 LAV. PAGES 1A & 1B.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT. 8377

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2001-09-19 Cont ID  
Sent By lhatten Date 2001-09-19 Time 19:48 Rev Time 4.00
Received By lhatten Date 2001-09-04 Time 19:45 Sent To  
Notes
2001-09-19 00:00:00REVIEW & STAMPED PLANS 09/04/2001-
 GOT WITH MICHELLE ON MECH & PLUMBING
 PROBLEMS TO BE CORRECTED PRIOR TO PERMIT
 BEING ISSUED! PER LOU HATTEN
 ALL SUB TRADES PROBLEMS - BOTH MECH &
 PLUMBING RESOVLED09/19/2001

Review Stop Z ZONING
Rev No 1 Status P Date 2001-08-03 Cont ID  
Sent By sgraham Date 2001-08-03 Time 10:36 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***