Plan Review Details - Permit 01071385
Plan Review Stops For Permit 01071385
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2002-05-16 Cont ID  
Sent By jwitmer Date 2002-05-16 Time 08:04 Rev Time 0.15
Received By jwitmer Date   Time   Sent To  
Notes
2002-05-16 00:00:00TYPE IV 2ND FL INTERIOR SHUTTERS
 1ST FL EXTERIOR MOUNT

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-01-10 Cont ID  
Sent By jwitmer Date 2002-01-10 Time 11:09 Rev Time 1.25
Received By jwitmer Date 2002-01-10 Time 07:04 Sent To  
Notes
2002-01-10 00:00:00BUILDNIG TYPE IV
 MASTER: 01071385
 BUILDING PROVISO:
 NO SURVEY WITH PLANS, TABLE 600 ISSUES
 CAN NOT BE ADDRESSED (WINDOW OPENINGS VS
 PROPERTY LINE. THIS CONCERN WILL BE
 ADDRESSED ON A INDIVIDUAL PERMIT BASIS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2001-11-29 Cont ID  
Sent By jwitmer Date 2001-11-29 Time 06:48 Rev Time 0.50
Received By jwitmer Date 2001-11-29 Time 06:41 Sent To  
Notes
2001-11-29 00:00:00BUILDING PLAN REVIEW
 PLAN REVIEW3 01071385
 TYPE IV "EDGF"
 CONT: TRANSEASTERN
 TEL: 753-5531
  
  
  
 SEE COMMENTS LISTED UNDER 01071374

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2001-10-23 Cont ID  
Sent By dpalmer Date 2001-10-23 Time 21:27 Rev Time 0.00
Received By dpalmer Date 2001-10-23 Time 21:27 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2001-08-21 Cont ID  
Sent By dpalmer Date 2001-08-21 Time 09:02 Rev Time 0.00
Received By dpalmer Date 2001-08-21 Time 09:02 Sent To  
Notes
2001-08-21 00:00:00*************** UNSAT *****************
  
 1)NOTE: PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW EQUIPMENT BEING INSTALLED.
 MAINS/PANELS/BREAKERS MUST BE RATED FOR
 THE AVAILABLE FAULT CURRENT PER 110-9.
  
 2) NOTE: PLEASE SHOW GROUNDING ELECTRODE
 GOING TO BUILDING STEEL AND COLD WATER
 PER 250-50.
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2001-11-19 Cont ID  
Sent By mcarsill Date 2001-11-19 Time 12:59 Rev Time 0.00
Received By mcarsill Date 2001-11-19 Time 12:59 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2001-10-04 Cont ID  
Sent By mcarsill Date 2001-10-04 Time 16:39 Rev Time 0.00
Received By mcarsill Date 2001-10-04 Time 16:39 Sent To  
Notes
2001-10-04 00:00:00NOT ALL PREVIOUS PLAN REVIEW COMMENTS
 ADDRESSED.
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2001-08-07 Cont ID  
Sent By mcarsill Date 2001-08-07 Time 14:37 Rev Time 0.00
Received By mcarsill Date 2001-08-07 Time 14:37 Sent To  
Notes
2001-08-07 00:00:001) PROVIDE SITE PLAN FOR BUILDING.
 2) PROVIDE FIRE HYDRANT LOCATIONS.
 WET FIRE HYDRANTS ARE REQUIRED PRIOR TO,
 DURING AND AFTER CONSTRUCTION.
 3) BUILDING ADDRESSES REQUIRED.
 4) ARE THE BUILDINGS RENTALS OR OWNED.
 5) TENANT SEPARATIONS TO COMPLY WITH
 WITH BUILDING CODE REQUIREMENTS.
 6) ELECTRIC POWERED SMOKE DETECTORS ARE
 REQUIRED. WHEN ACTIVATED, THESE DEVICES
 ARE TO BE AUDIBLE IN THE SLEEPING ROOMS
 OF THAT UNIT.
 7) PORTABLE FIRE EXTINGUISHERS ARE
 REQUIRED.
 8) STORAGE NOT PERMITTED UNDER STAIRS
 UNLESS PROPERLY FIRE RATED.
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2002-01-23 Cont ID  
Sent By pkrauss Date 2002-01-23 Time 09:29 Rev Time 1.00
Received By pkrauss Date 2002-01-23 Time 07:44 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2001-10-13 Cont ID  
Sent By pkrauss Date 2001-10-13 Time 10:10 Rev Time 0.05
Received By pkrauss Date   Time   Sent To  
Notes
2001-10-13 00:00:00NO MECH PLANS SUBMITTED

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2001-10-13 Cont ID  
Sent By pkrauss Date 2001-10-13 Time 10:09 Rev Time 0.05
Received By pkrauss Date   Time   Sent To  
Notes
2001-10-13 00:00:00NO MECH PER N. DENMARK 8-23-01

Review Stop P PLUMBING
Rev No 4 Status P Date 2002-01-11 Cont ID  
Sent By kstevens Date 2002-01-11 Time 17:41 Rev Time 0.50
Received By kstevens Date 2002-01-11 Time 17:41 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2001-11-21 Cont ID  
Sent By kstevens Date 2001-11-21 Time 21:00 Rev Time 0.50
Received By kstevens Date 2001-11-21 Time 21:00 Sent To  
Notes
2001-11-21 00:00:00DENIED
  
 AS PER PREVIOUS PLAN REVIEWS, APPROVED
 UTILITY PLANS ARE REQUIRED FOR FINAL
 PLUMBING PLAN REVIEW. THIRD NOTICE
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT. 8377

Review Stop P PLUMBING
Rev No 2 Status F Date 2001-10-29 Cont ID  
Sent By kstevens Date 2001-10-29 Time 11:30 Rev Time 0.50
Received By kstevens Date 2001-10-29 Time 11:30 Sent To  
Notes
2001-10-29 00:00:00DENIED
 REFERENCE: SPC-94
  
 1) APPROVED UTILITY PLANS ARE REQUIRED
 FOR FINAL PLUMBING PLAN REVIEW OF BUILD-
 INGS.
  
 2) PAGES A-3/A-10 M/BATH, 2 LAVS ON
 FLOOR PLAN, 1 SHOWN ON RISER PLEASE
 CLAIRFY.
  
 3) PAGES A-3/A-11 "G" UNIT 2ND FLOOR
 DOES NOT REFLECT FLOOR PLAN. TUB BATH
 LAV ON RIGHT HAND SIDE OF W/C. M/BATH
 ONLY 1 LAV, (2 SHOWN), & SHR ON RIGHT
 SIDE OF W/C.
  
 4) PAGES A-3/A-10 "D" UNIT. LAVS & SHOW-
 ER ON LEFT SIDE OF W/C, DOES NOT REFLECT
 FLOOR PLAN. M/BATH
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT. 8377

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-08-16 Cont ID  
Sent By jleech Date 2001-08-16 Time 17:23 Rev Time 0.00
Received By jleech Date   Time   Sent To  
Notes
2001-08-16 00:00:00SEE 01071374 FOR PLAN REVIEW NOTES

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status N Date 2002-01-23 Cont ID  
Sent By jwitmer Date 2002-01-23 Time 07:14 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2001-08-27 Cont ID  
Sent By hpiskura Date 2001-08-27 Time 11:32 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
2001-08-27 00:00:00SEE NOTES ON 01071374

Review Stop Z ZONING
Rev No 2 Status P Date 2002-01-22 Cont ID  
Sent By drunnels Date 2002-01-22 Time 14:20 Rev Time 0.25
Received By drunnels Date   Time   Sent To  
Notes
2002-01-22 00:00:00SITE PLAN APPROVED PER MIKE SANCHEZ
 01/22/02 DR

Review Stop Z ZONING
Rev No 1 Status F Date 2001-12-10 Cont ID  
Sent By sgraham Date 2001-12-10 Time 09:55 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
2001-12-10 00:00:00NO APPROVED SITE PLLAN