Plan Review Stops For Permit 01071271 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2002-01-07 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2002-01-07 |
Time |
18:46 |
Rev Time |
0.50 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2001-09-24 |
|
|
Cont ID |
|
Sent By |
hpiskura |
Date |
2001-09-24 |
Time |
13:49 |
Rev Time |
0.00 |
Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2001-08-13 |
|
|
Cont ID |
|
Sent By |
hpiskura |
Date |
2001-08-13 |
Time |
14:43 |
Rev Time |
0.00 |
Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-08-13 00:00:00 | PLEASE PROVIDE A RECENT SURVEY AND A | | SITE PLAN. | | | | BEFORE A PERMIT TO CONSTRUCT CAN BE | | ISSUED IMPACT FEES MUST BE PAID TO PALM | | BEACH COUNTY.CALL 561-233-5025 FOR | | MORE INFORMATION. | | | | PROVIDE TEST REPORTS FOR THE WINDOWS, | | DOORS AND ROOF COVERING. | | | | PROVIDE A SEATING PLAN FOR THE CARDIAC | | THEATRE AND ALL OF THE DINING AREAS. | | SEE SBC 1003.1.2. | | | | SHOW THE MEANS OF ROOF DRAINAGE AND | | EMERGENCY OVERFLOW FOR THE NEW FLAT | | ROOF AREA.SEE SBC 1517.6.4. | | | | PROVIDE TWO EXITS FROM THE DINING AREA(S | | SEE SBC 1004.2. | | | | SHOW THE METHOD OF TRUSS CONNECTION TO | | THE EXISTING CONDITIONS AS WELL AS THE | | DESIGN LOADS INCLUDING THE ROOF TOP | | EQUIPMENT.SEE SBC 104.2. | | | | PROVIDE THREE COPIES OF ENERGY CODE | | CALCULATIONS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2001-12-26 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-12-26 |
Time |
20:42 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-12-26 |
Time |
20:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2001-09-19 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-09-19 |
Time |
22:23 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-09-19 |
Time |
22:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2001-08-13 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-08-13 |
Time |
19:03 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-08-13 |
Time |
19:03 |
Sent To |
|
|
Notes |
2001-08-13 00:00:00 | *************** UNSAT **************** | | | | 1)NOTE: PLEASE NOTE THAT ALL BRANCH | | CIRCUIT #`S NEED TO BE SHOWN PLANS AND | | CORRELATE WITH SUBMITTED PANEL SCHEDULES | | | | 2)NOTE: PLEASE SUBMIT LOAD CALCULATIONS | | FOR ADDING LOADS TO EXISTING.215-5 | | | | 3)NOTE: PLEASE CLARIFY EQUIPMNET GROUND- | | -ING METHOD. SIZE PER 250-122 | | | | 4)NOTE: PLEASE CLARIFY BONDING OF NEW | | FOOTER STEEL OF NEW ADDITION. 250-50 | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
N |
Date |
2001-09-24 |
|
|
Cont ID |
|
Sent By |
hpiskura |
Date |
2001-09-24 |
Time |
07:41 |
Rev Time |
0.00 |
Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2001-12-27 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2001-12-27 |
Time |
09:14 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2001-12-27 |
Time |
09:14 |
Sent To |
|
|
Notes |
2001-12-27 00:00:00 | SEPARATE PLANS AND PERMITS REQUIRED FOR | | THE HOOD, DUCT AND EXTINGUISHING | | SYSTEM. | | | | MIKE CARSILLO, CAPTAIN | | 659-8096,EXT.8497 | | 835-2910 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2001-09-18 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2001-09-18 |
Time |
08:05 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2001-09-18 |
Time |
08:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2001-08-02 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2001-08-02 |
Time |
15:50 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2001-08-02 |
Time |
15:50 |
Sent To |
|
|
Notes |
2001-08-02 00:00:00 | 1) PLEASE CLEARLY IDENTIFY ALL EXIT | | SIGN LOCATIONS. | | 2) PLEASE CLEARLY IDENTIFY ALL | | EMERGENCY LIGHT FIXTURES LOCATIONS. | | 3) PLEASE PROVIDE INTERIOR FINISH | | CLASSIFICATION INFORMATION. | | 4) PLEASE PROVIDE A LIFE SAFETY PLAN | | AND AN OCCUPANT LOAD PLAN. | | 5) ARE THERE ANY FIRE SPRINKLER OR FIRE | | ALARM EQUIPMENT PRESENT WITHIN THE | | BUILDING. | | | | CAPTAIN MIKE CARSILLO | | 659-8096,EXT.8497 | | 835-2910 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
N |
Date |
2002-01-11 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2002-01-07 |
Time |
07:32 |
Rev Time |
0.35 |
Received By |
pkrauss |
Date |
2002-01-05 |
Time |
11:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
N |
Date |
2001-12-20 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2001-12-20 |
Time |
10:02 |
Rev Time |
0.50 |
Received By |
pkrauss |
Date |
2001-12-20 |
Time |
10:01 |
Sent To |
|
|
Notes |
2001-12-20 00:00:00 | | | ADDITIONAL PLANS AND PERMIT REQUIRED FOR | | HOOD, FIRE SUPRESSION, AND WALK-IN | | COOLER.PLEASE PROVIDE MANUFACURER | | SUBMITTAL DATA/PRODUCT APPROVAL FOR THE | | FIRE WRAP. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT 659-8096 | | EXT. 8388. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2001-09-26 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2001-09-26 |
Time |
09:40 |
Rev Time |
0.45 |
Received By |
pkrauss |
Date |
2001-09-26 |
Time |
09:25 |
Sent To |
|
|
Notes |
2001-09-26 00:00:00 | *******************PROVISO************** | | | | | | MANUFACUTURER SUBMITTAL AND INSTALLATION | | INFORMATION FOR THE CURB TO THE RTU'S | | SHALL BE ON THE JOBSITE WITH PLANS AT | | THE TIME OF INPECTION. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT 659-8096 EXT. | | 8388. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2001-08-13 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2001-08-13 |
Time |
16:46 |
Rev Time |
0.40 |
Received By |
ndenmark |
Date |
2001-08-13 |
Time |
16:46 |
Sent To |
|
|
Notes |
2001-08-14 00:00:00 | PROVIDE INFORMATION ON CONDENSATE DRAIN | | LOCATION AND TERMINATION.(NOT ON ROOF) | | | | NO ENERGY EFFICIENCY VALUES SHOWN FOR | | AIR HANDLING EQUIPMENT. PROVIDE | | INFORMATION SHOWING COMPLIANCE WITH FL | | ENERGY CODE. | | | | PROVIDE CURB ATTACHMENT INFORMATION | | SHOWING COMPLIANCE WITH WIND LOAD | | (STRUCTURAL SHOWS RAILS NOT CURBS) | | | | EXHAUST PER ASHRAE 62-89 AND SMC | | 503.3.2SHALL BE PROVIDED. PROVIDE | | INFORMATION ON FANS AND INSTALLATION | | DETAILS FOR SHOWER AREAS. | | | | CEILING PADDLE FANS TO BE MINIMUM 8 FOOT | | ABOVE FINISHED FLOOR PER SMC 404.3.2 | | | | PROVIDE INFORMATION ON EQUIPMENT ACCESS | | ON ROOF. ELECTRIC FOR ROOF EQUIPMENT | | SHALL INCLUDE 115V GFIC OUTLET. | 2001-08-13 00:00:00 | ********************DENIED************** | | | | | | | | PLEASE PROVIDE THE FOLLOWING INFORMATION | | FOR REVIEW. | | | | | | 1.OUTSIDE AIR CALCULATIONS AS PER | | ASHRAE 62-89. | | | | 2.AIR BALANCE SCHEDULE TO SHOW | | COMPLIANCE WITH 1997 SMC 501.2. | | | | 3.FAN SHUTDOWN BY DUCT SMOKE DETECTOR | | WITH NOTIFICATION TO ALARM/STROBE IN | | NORMALLY OCCUPIED AREAS AS PER | | 1997 SMC 406.1 AND NFPA 90A 4-4.4.3. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
F |
Date |
2002-01-14 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2002-01-14 |
Time |
12:20 |
Rev Time |
1.25 |
Received By |
kstevens |
Date |
2002-01-14 |
Time |
12:20 |
Sent To |
|
|
Notes |
2002-01-14 00:00:00 | DENIED | | REFERENCE: SPC-94-FACBC-97 | | | | 1) SHT K-PLUMB SANITARY RISER DIAGRAM, | | TRAP FOR CAN WASH TO BE UNDERGROUND, NOT | | ON STACK AS SHOWN | | | | 2) RISER DIAGRAM, HORIZONTAL DRY VENT | | NOT APPROVED PER SPC SEC 906.2.1 | | | | 3) SEPARATE PLUMBING PERMIT REQUIRED | | | | 4) SEPARATE GAS PERMIT REQUIRED. SEE | | ATTACHED GAS PERMIT REQUIREMENT SHEET | | FOR INFORMATION REQUIRED FOR GAS PLAN | | REVIEW. | | | | 5) PLEASE SUBMIT KITCHEN EQUIPMENT IDENT | | IFICATION SHEET. | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2001-10-02 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2001-10-02 |
Time |
10:15 |
Rev Time |
1.00 |
Received By |
kstevens |
Date |
2001-10-02 |
Time |
10:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2001-09-26 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2001-09-26 |
Time |
17:17 |
Rev Time |
1.25 |
Received By |
kstevens |
Date |
2001-09-26 |
Time |
17:17 |
Sent To |
|
|
Notes |
2001-09-26 00:00:00 | DENIED | | REFERENCE: SPC-94 - FACBC-97 - SMC-97 | | 1) PAGES D-1/A-6 PROVIDE SANITARY RISER | | DIAGRAM AND WATER RISER DIAGRAM FOR NEW | | SINKS. | | 2) PAGES D-1/A-6 PLEASE PROVIDE INFOR- | | MATION FOR STEAM GENERATOR. WHAT IS THE | | STEAM FOR? PROVIDE PIPING INFORMATION. | | 3) PAGES D-1/A-7 RELOCATION OF WATER | | HEATER. PREVIOUS PLAN REVIEW NOT ADDRES- | | SED. PLEASE SHOW INFORMATION ON WORKING | | PLATFORM, LIGHT, WALKWAK TO HEATER (MIN- | | IMUM 24" WIDE) AND ACCESS SIZE. PER | | SMC-97 SEC 304.4, SPC-94 SEC 501.7. | | 4) PAGE A-7 PROVIDE DETAILS ON PAN, PAN | | DRAIN AND T&P DRAIN LINE FROM W/HEATER. | | SPC-94 SEC 507.8.1,2,2 AND 4. | | 5) PAGE A-3 PLEASE PROVIDE ROOF DRAIN | | CALCULATIONS FOR ROOF DRAIN PER SPC-94 | | SEC 1108. ALSO PROVIDE SECONDARY ROOF | | DRAIN CALCULATIONS USING SEC 1109. | | SHOW RISER DIAGRAMS FOR BOTH WITH ALL | | PIPE SIZES. | | 6) PAGE A-6 PREVIOUS COMMENTS #1 AND #2 | | FROM PLAN REVIEW DATED 8-9-01 WERE NOT | | ADDRESSED. PLEASE SHOW COMPLIANCE FOR | | DRESSING ROOMS PER FACBC SEC 4.35 THRU | | 4.35.5. ALSO SHOW COMPLIANCE FOR SHOWERS | | PER FACBC SEC 4.21 THRU 4.21.4 AND FIG. | | 35. | | 7) PAGE A-6 WATER RISER DIAGRAM. PLEASE | | LOCATE WATER HAMMER ARRESTORS PER MANU- | | FACTURES INSTALLATION INSTRUCTIONS AND | | WH-PDI 201, NOT AT TOP OF DROP AS SHOWN. | | 8) PAGE A-6 PLEASE PROVIDE CALCULATIONS | | FOR MINIMUM FIXTURES USING SPC-94 TABLE | | 407. SHOW DETAILS OF ALL RESTROOMS, GIVE | | ROOM DIMENTIONS ECT. | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT. 8377 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2001-08-09 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2001-08-09 |
Time |
18:00 |
Rev Time |
1.50 |
Received By |
jleech |
Date |
2001-08-09 |
Time |
18:00 |
Sent To |
|
|
Notes |
2001-08-09 00:00:00 | DENIED; | | | | 1.PAGE A-6 DRESSING ROOMS SHALL COMPLY | | WITH FACBC SEC. 4.35 THRU 4.35.5. | | 2.SHOWER STALLS SHALL COMPLY WITH FACBC | | SEC. 4.21 THRU 4.21.4, ALSO SEE FIG. | | 35. | | 3.PAGE A-6 WHAT IS 2" PLUMBING DRAIN FOR | | SHOWER DRAIN IS 3" WHAT ELSE IS BEING | | ADDED? | | 4.WATER HEATER MUST BE READILY ACCESS- | | IBLE. IF RELOCATED IN ATTIC A FIXED | | LADDERSHALL BE AVAILABLE AND A WORKING | | PLATFORM MUST BE IN PLACE WITH A LIGHT | | SPC SEC. 501.7. | | 5.WATER HEATER PAN AND DRAIN SHALL | | COMPLY WITH SEC. 507.8.1,2,3, AND .4. | | | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 659-8096 EXT. 8369 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2001-07-31 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2001-07-31 |
Time |
09:00 |
Rev Time |
0.25 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-07-31 00:00:00 | NEED MINOR AMENDMENT & FORMAL SITE PLAN |
|
|