Plan Review Details - Permit 01070941
Plan Review Stops For Permit 01070941
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-08-08 Cont ID  
Sent By dpalmer Date 2001-08-08 Time 17:57 Rev Time 0.00
Received By dpalmer Date 2001-08-08 Time 17:57 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2001-08-06 Cont ID  
Sent By mcarsill Date 2001-08-06 Time 09:53 Rev Time 0.00
Received By mcarsill Date 2001-08-06 Time 09:53 Sent To  
Notes
2001-08-06 00:00:001) BUILDING ADDRESSES REQUIRED.
 2) WET FIRE HYDRANTS REQUIRED PRIOR TO,
 DURING AND AFTER CONSTRUCTION.
 3) ELECTRIC POWERED SMOKE DETECTORS
 REQUIRED. WHEN ACTIVATED, THESE DEVICES
 ARE TO BE AUDIBLE IN THE SLEEPING ROOMS
 OF THAT UNIT.
 4) PORTABLE FIRE EXTINGUISHERS ARE
 REQUIRED.
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-10-31 Cont ID  
Sent By pkrauss Date 2001-10-31 Time 08:53 Rev Time 0.30
Received By pkrauss Date 2001-10-31 Time 08:53 Sent To  
Notes
2001-10-31 00:00:00MECH REV PERMIT 01070951

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-07-28 Cont ID  
Sent By hmoser Date 2001-07-28 Time 10:35 Rev Time 0.33
Received By hmoser Date 2001-07-28 Time 10:35 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2001-07-28 Cont ID  
Sent By jleech Date 2001-07-28 Time 07:35 Rev Time 0.25
Received By jleech Date 2001-07-28 Time 07:35 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2001-10-22 Cont ID  
Sent By jgomez Date 2001-10-22 Time 15:52 Rev Time 0.25
Received By jgomez Date 2001-10-22 Time 15:52 Sent To  
Notes
2001-10-22 00:00:00TRUSS DRAWINGS REVIEW.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2001-10-10 Cont ID  
Sent By jgomez Date 2001-10-10 Time 18:31 Rev Time 0.50
Received By jgomez Date 2001-10-10 Time 18:31 Sent To  
Notes
2001-10-10 00:00:00CHECKLIST:
 1-UPDATE GENERAL DETAILS WITH LEGIBLE
 DRAWINGS AND UPDATED CODES.
 2-ENGINEER IS SIGNING AND SEALING COPIES
 OF GENERAL TRUSS DETAILS WITH THE
 SEAL & SIGNATURE OF ANOTHER ENGINEER.
 ONLY ONE ENGINEER TO SIGN AND SEAL
 THESE DOCUMENTS AND PROVIDE THE
 DOCUMENTATION REQUIRED BY FLORIDA
 STATUTES WHEN CHANGING ENGINEERS.
 3-SOME ENGINEERED TRUSSES ARE DESIGNED
 USING ASCE 7-93.CHECK THEM AND
 REVISED AS REQUIRED.
 4-ARCHITECT TO SPECIFY UPLIFT CONNECTOR
 FOR TRUSS S15 AT THE MID POINT
 BEARING AREA.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2001-08-09 Cont ID  
Sent By jgomez Date 2001-08-09 Time 17:55 Rev Time 1.00
Received By jgomez Date 2001-08-09 Time 17:55 Sent To  
Notes
2001-08-09 00:00:00APPROVED WITH PROVISO:
 1-FLOOD ZONE AO. NEED TO PROVIDE THE
 ELEVATION CERTIFICATE.
 2-SPECIFY SAFETY GLASS WHERE REQUIRED.
 SECTION 2405.2 SBC 1997. SEE OPTION
 OF WINDOWS INSTEAD OF SLIDING GLASS
 DOORS AT KITCHEN.
 3-REVISE DESIGN CERTIFICATION FOR
 BUILDING CODE COMPLIANCE FORM. THE
 MEAN ROOF HEIGHT AND THE DESIGN
 PRESSURES SPECIFIED DON'T MATCH.
 SEE TABLE 1606.2A SBC 1997.
 4-PROVIDE DADE COUNTY PRODUCT APPROVAL
 FOR WINDOW MULLIONS.
  
  
  
  
  
  
 NOTES:
 1-DRAWINGS TO BE FILED UNDER PERMIT #
 01070941.
 2-THESE COMMENTS APPLY TO PERMIT #S:
 01070941, 01070942, 01070944 AND
 01070945.

Review Stop Z ZONING
Rev No 1 Status P Date 2001-07-25 Cont ID  
Sent By sgraham Date 2001-07-25 Time 11:47 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***