Plan Review Details - Permit 01070890
Plan Review Stops For Permit 01070890
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2001-11-07 Cont ID  
Sent By lsmith Date 2001-11-07 Time 14:32 Rev Time 0.50
Received By lsmith Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2001-10-26 Cont ID  
Sent By dpalmer Date 2001-11-06 Time 22:07 Rev Time 1.50
Received By lsmith Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2001-08-23 Cont ID  
Sent By lsmith Date 2001-08-23 Time 10:27 Rev Time 2.50
Received By lsmith Date   Time   Sent To  
Notes
2001-08-23 00:00:00*************BUILDING UNSAT*************
  
 SBC 104.2.2
  
 1. PROVIDE 2 CURRENT COPIES OF SIGN AND
 SEALED SURVEYS WITH PROPOSED IMPROVEMENT
 TO BE DONE.
  
 2. PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
  
 3. PROVIDE FLOOD ZONE ELEVATION
 CERTIFICATE FOR NEW CONSTRUCTION WITH
 BFE BEFORE C/O
  
 4. PROVIDE 2 CURRENT COMPLETE COPIES OF
 SBCCI OR METRO DADE PRODUCT APPROVALS
 OR ENGINEERED SITE SPECIFIC:
 WINDOWS, DOORS, FIXED GLASS, GLASS
 BLOCK
  
 5. PROVIDE ATTIC ACCESS PER 1997 SBC SEC
 2309.6.
  
 6. BEFORE A PERMIT TO CONSTRUCT CAN BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH CO.,THE PERMIT PLANS STAMPED BY
 THEM AND THE RECEIPT ATTACHED TO THE
 PERMIT APPLICATION.
  
 7. SUBMITT ENGINEERED SIGNED & SEALED
 TRUSS DRAWINGS APPROVED BY THE ARCHITECT
 OF RECORD.

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2002-02-11 Cont ID  
Sent By dpalmer Date 2002-02-11 Time 17:51 Rev Time 0.00
Received By dpalmer Date 2002-02-11 Time 17:51 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2001-12-04 Cont ID  
Sent By dpalmer Date 2001-12-04 Time 18:00 Rev Time 0.00
Received By dpalmer Date 2001-12-03 Time 13:07 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2001-11-06 Cont ID  
Sent By dpalmer Date 2001-11-06 Time 21:56 Rev Time 0.00
Received By dpalmer Date 2001-11-06 Time 21:56 Sent To B
Notes
2001-11-06 00:00:00***************UNSAT ***************
  
 1)NOTE: PLEASE NOTE THAT PLANS ARE NOW
 SHOWING A NEW 200AMP MAIN AND PANEL
 AND CONDUCTORS STILL REFLECT OLD 150A
 SERVICE. PLEASE CORRELATE WIRE SIZE WITH
 OCP.310-15.
  
 2)NOTE:PLEASE NOTE THAT EACH HANDWRITTEN
 CHANGEON PLANS MUST BE EITHER SIGNED,
 DATED OR RE-PRINT AND SIGN, AND SEAL.
  
 PLEASE SUBMIT THE ABOVE FOR REVIEW.
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-08-07 Cont ID  
Sent By dpalmer Date 2001-08-07 Time 09:37 Rev Time 0.00
Received By dpalmer Date 2001-08-07 Time 09:37 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2001-08-23 Cont ID  
Sent By lsmith Date 2001-08-23 Time 10:27 Rev Time 0.00
Received By lsmith Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status N Date 2001-08-23 Cont ID  
Sent By lsmith Date 2001-08-23 Time 10:27 Rev Time 0.00
Received By lsmith Date   Time   Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2002-01-29 Cont ID  
Sent By pkrauss Date 2002-01-29 Time 09:28 Rev Time 0.40
Received By pkrauss Date 2002-01-29 Time 09:16 Sent To  
Notes
2002-01-29 00:00:00MECHANICAL PERMIT 01101148
  
 PROVISO:
  
 PRIOR TO FINAL INSPECTION ALL A/C DROPS
 IN THE SPACE SHALL BE REMOVED.SUBMIT
 PLANS INDICATING A/C & PARTITIONS ARE
 REMOVED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-07-21 Cont ID  
Sent By hmoser Date 2001-07-21 Time 12:50 Rev Time 0.33
Received By hmoser Date 2001-07-21 Time 12:44 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2002-02-28 Cont ID  
Sent By kstevens Date 2002-02-28 Time 14:55 Rev Time 0.50
Received By kstevens Date 2002-02-28 Time 14:55 Sent To  
Notes
2002-02-28 00:00:00REVISION OK SANITARY RISER DIAGRAM.

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-10-23 Cont ID  
Sent By jleech Date 2001-10-23 Time 17:04 Rev Time 0.33
Received By jleech Date 2001-10-23 Time 17:04 Sent To  
Notes
2001-10-23 00:00:00RE-SUB NO CHANGES TO PLUMBING

Review Stop P PLUMBING
Rev No 1 Status P Date 2001-07-21 Cont ID  
Sent By jleech Date 2001-07-21 Time 08:59 Rev Time 0.25
Received By jleech Date 2001-07-21 Time 08:59 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2001-10-24 Cont ID  
Sent By sgraham Date 2001-10-24 Time 10:15 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***