Plan Review Details - Permit 01070586
Plan Review Stops For Permit 01070586
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-02-01 Cont ID  
Sent By lmartine Date 2002-02-01 Time 07:40 Rev Time 1.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2001-08-07 Cont ID  
Sent By hpiskura Date 2001-08-07 Time 15:03 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2002-02-14 Cont ID  
Sent By dpalmer Date 2002-02-14 Time 07:21 Rev Time 0.00
Received By dpalmer Date 2002-02-14 Time 07:21 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2001-08-21 Cont ID  
Sent By dpalmer Date 2001-08-21 Time 22:20 Rev Time 0.00
Received By dpalmer Date 2001-08-21 Time 22:20 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2001-08-07 Cont ID  
Sent By dpalmer Date 2001-08-07 Time 19:19 Rev Time 0.00
Received By dpalmer Date 2001-08-07 Time 19:19 Sent To  
Notes
2001-08-07 00:00:00*************REVISION REQUESTED *******
  
 1)NOTE: PLEASE NOTE THAT PLANS NEED TO
 HAVE ALL NEW BRANCH CIRCUIT #`S SHOWN
 FOR CIRCUITING, AND CORRELATE WITH
 SUBMITTED PANEL SCHEDULES.
  
 PLEASE REVISE AND SUBMIT THE ABOVE AS A
 REVSION BEFORE FINAL OR REVISE BEFORE
 RESUB SINCE PLANS ARE COMING BACK FOR
 FIRE DEPT COMMENTS.
 REVISION FEE WILL BE DUE BEFORE FINAL.
  
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2001-08-08 Cont ID  
Sent By pkrauss Date 2001-08-08 Time 15:04 Rev Time 0.05
Received By pkrauss Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2002-02-13 Cont ID  
Sent By mcarsill Date 2002-02-13 Time 15:42 Rev Time 0.00
Received By mcarsill Date 2002-02-13 Time 15:42 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2002-01-15 Cont ID  
Sent By mcarsill Date 2002-01-15 Time 09:13 Rev Time 0.00
Received By mcarsill Date 2002-01-15 Time 09:13 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2001-08-20 Cont ID  
Sent By mcarsill Date 2001-08-20 Time 17:27 Rev Time 0.00
Received By mcarsill Date 2001-08-20 Time 17:27 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2001-08-02 Cont ID  
Sent By mcarsill Date 2001-08-02 Time 18:39 Rev Time 0.00
Received By mcarsill Date 2001-08-02 Time 18:38 Sent To  
Notes
2001-08-02 00:00:001) PLEASE PROVIDE INTERIOR FINISH
 CLASSIFICATION INFORMATION FOR WALLS
 AND CEILINGS.
 2) NO FIRE ALARM SYSTEM DEVICES SHOWN
 ON PLANS. ARE THERE ANY EXISTING OR
 NEW FIRE ALARM DEVICES PLANNED FOR THE
 SPACE.
 3) SELF-CLOSING DEVICES REQUIRED FOR
 ALL RATED FIRE DOORS.
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2001-08-08 Cont ID  
Sent By pkrauss Date 2001-08-08 Time 15:02 Rev Time 0.35
Received By pkrauss Date 2001-08-08 Time 15:02 Sent To  
Notes
2001-08-08 00:00:00 
  
 INSUFFICIENT INFORMATION FOR MECHANICAL
 REVIEW.PLEASE SUBMIT PLANS WITH
 MECHANICAL PERMIT APPLICTION.
  
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT
 PATTY KRAUSS AT 659-8096 EXT.8388.

Review Stop P PLUMBING
Rev No 5 Status P Date 2002-03-07 Cont ID  
Sent By kstevens Date 2002-03-07 Time 17:42 Rev Time 0.75
Received By kstevens Date 2002-03-07 Time 17:42 Sent To  
Notes
2002-03-07 00:00:00PASSED/PROVISO
  
 VENT FROM SUMP TO VENT SEPARATELY TO
 OPEN AIR SPC SEC 915

Review Stop P PLUMBING
Rev No 4 Status F Date 2002-03-06 Cont ID  
Sent By kstevens Date 2002-03-06 Time 19:17 Rev Time 0.50
Received By kstevens Date 2002-03-06 Time 19:17 Sent To  
Notes
2002-03-06 00:00:00DENIED
 REFERENCE:SPC-94 - FACBC-97
  
 SUBMITTAL NOT APPROVED. MFG INFORMATION
 SHALL SHOWING LISTING FOR PUMPS.
  
 VENT FOR PUMPS SHALL BE CARRIED SEPAR-
 ATELY TO THE OPEN AIR. SPC SEC 915
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 3 Status F Date 2002-02-13 Cont ID  
Sent By kstevens Date 2002-02-13 Time 14:17 Rev Time 0.50
Received By kstevens Date 2002-02-13 Time 14:17 Sent To  
Notes
2002-02-13 00:00:00DENIED
 REFERENCE: SPC-94-FACBC-97
  
 1) SHT E-1 EXAMS #5 & #6 RISER DIAGRAM.
 PLEASE SUBMIT MANUFACTURE INFORMATION ON
 PUMPS FOR DRAINAGE.
 2) SHT E-1 EXAM ROOM #7, IS SINK TO BE
 INSTALLED, OR FOR FUTURE? IF INSTALLED
 SHOW ON RISER DIAGRAM.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-01-28 Cont ID  
Sent By kstevens Date 2002-01-28 Time 11:58 Rev Time 1.25
Received By kstevens Date 2002-01-22 Time 18:36 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2001-07-29 Cont ID  
Sent By jleech Date 2001-07-29 Time 12:19 Rev Time 0.75
Received By jleech Date 2001-07-29 Time 12:19 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status N Date 2001-08-08 Cont ID  
Sent By pkrauss Date 2001-08-08 Time 15:05 Rev Time 0.05
Received By pkrauss Date   Time   Sent To  
Notes
***NONE***