Plan Review Details - Permit 01070261
Plan Review Stops For Permit 01070261
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2001-12-04 Cont ID  
Sent By jwitmer Date 2001-12-04 Time 14:05 Rev Time 0.50
Received By jwitmer Date   Time   Sent To  
Notes
2001-12-04 00:00:00ARCHETECT JEROME BAUMOEHL SIGNED & DATED
 REVISIONS TO BOTH SETS OF PLANS 12/04 JW

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2001-11-27 Cont ID  
Sent By jwitmer Date 2001-11-27 Time 17:21 Rev Time 0.50
Received By jwitmer Date 2001-11-27 Time 17:21 Sent To  
Notes
2001-11-27 00:00:00BUILDING PLAN REVIEW
 1601 BELVEDERE RD #500
 J. DIMAREO
 TEL: (954) 596-2772
  
 1) ORIGINAL PLANS WERE RED LINEDE BY
 ARCHETECT. THE RESTAMPNEEDS TO SHOW THE
 CORRECTIONS.
 2)- THE "RESTAMP" PLANS ALSO INDICATE
 REVISIONS ON SHEET #5 TO PAY FOR MECHAN-
 ICAL REVISION.
 BUILDING PLAN REVIEW
 JIM WITMER
 (561)659-8096X 8412

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2001-08-06 Cont ID  
Sent By jwitmer Date 2001-08-06 Time 15:24 Rev Time 1.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2001-07-25 Cont ID  
Sent By jwitmer Date 2001-07-25 Time 17:25 Rev Time 1.25
Received By jwitmer Date   Time   Sent To  
Notes
2001-07-25 00:00:00PERMIT # 01070261
 1601 BELVEDERE RD SUITE 500/506
 J DIMARO CONSTRUCTION
 (954) 596-2772
  
 SBC= STANDARD BUILDING CODE
 SBC*= STANDARD BUILDING CODE AMENDMENTS
 FBC= FLORIDA BUILDING CODE
 TO BE ADOPTED JAN. 1/2002
  
 1)- FL ACCESSIBILITY CODE 4.1.6.2(2)
 ALTERATIONS TO AN AREA CONTAINING A
 PRIMARY FUNCTION: THE EXISTING DOORS
 HIGHLIGHTED ON THE PLAN FAIL THE
 MANEUVERING CLEARENCES AT DOORS, 4.13.6.
 THE DISPROPORTIONATE COST STATED ABOVE
 IN SECTION 4.1.6.2(2) ALLOWS FOR 20% OF
 THE VALUE OF THE JOB OR $1,300.00 TO
 IMPROVE THE ACCESSIBILE ROUTE.
 SEE ATTACHMENTS
 2)-SHEET 1 DETAILS 1-4 SHOW 2X4 WOOD
 HEADERS SBC 609.2.1. TYPE I & TYPE II
 BUILDINGS REQUIRE NO WOOD IN PARTITIONS.
  
 3)- MISSING INFORMATION, THE MINIMUM
 INTERIOR FINISH SCHEDULE SBC TABLE 803.3
  
 BUILDING PLAN REVIEW
 JIM WITMER
 (561) 659-8096 X 8412

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-07-31 Cont ID  
Sent By dpalmer Date 2001-07-31 Time 18:09 Rev Time 0.00
Received By dpalmer Date 2001-07-31 Time 18:09 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2001-07-26 Cont ID  
Sent By lsmith Date 2001-07-26 Time 11:05 Rev Time 0.00
Received By lsmith Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2001-08-08 Cont ID  
Sent By mcarsill Date 2001-08-08 Time 09:01 Rev Time 0.00
Received By mcarsill Date 2001-08-08 Time 09:01 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2001-07-09 Cont ID  
Sent By mcarsill Date 2001-07-09 Time 12:03 Rev Time 0.00
Received By mcarsill Date 2001-07-09 Time 12:03 Sent To  
Notes
2001-07-09 00:00:001) PLANS DID NOT INDICATE WHERE EXISTING
 OR NEW FIRE ALARM EQUIPMENT IS LOCATED
 WITHIN THE SPACE(S).
 2) NO INTERIOR FINISH CLASSIFICATION
 INFORMATION PROVIDED WITH PLANS.
  
 CAPTAIN MIKE CARSILLO
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-07-30 Cont ID  
Sent By pkrauss Date 2001-07-30 Time 13:41 Rev Time 0.45
Received By pkrauss Date 2001-07-30 Time 13:41 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2001-07-26 Cont ID  
Sent By lsmith Date 2001-07-26 Time 11:06 Rev Time 0.00
Received By lsmith Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status N Date 2001-07-26 Cont ID  
Sent By lsmith Date 2001-07-26 Time 11:05 Rev Time 0.00
Received By lsmith Date   Time   Sent To  
Notes
***NONE***