Plan Review Details - Permit 01070113
Plan Review Stops For Permit 01070113
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-01-07 Cont ID  
Sent By btrobaug Date 2002-01-07 Time 13:09 Rev Time 0.50
Received By btrobaug Date 2002-01-07 Time 13:08 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-07-18 Cont ID  
Sent By dpalmer Date 2001-07-18 Time 07:03 Rev Time 0.00
Received By dpalmer Date 2001-07-18 Time 07:03 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2001-08-20 Cont ID  
Sent By mcarsill Date 2001-08-20 Time 09:03 Rev Time 0.00
Received By mcarsill Date 2001-08-20 Time 09:03 Sent To  
Notes
2001-08-20 00:00:001) BUILDING ADDRESSES REQUIRED.
 2) WET FIRE HYDRANTS ARE REQUIRED PRIOR
 TO, DURING AND AFTER CONSTRUCTION.
 3) ELECTRIC POWERED SMOKE DETECTORS ARE
 REQUIRED. WHEN ACTIVATED, THESE DEVICES
 ARE TO BE AUDIBLE IN THE SLEEPING ROOMS
 OF THAT UNIT.
 4) PORTABLE FIRE EXTINGUISHERS ARE
 REQUIRED.
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-07-14 Cont ID  
Sent By hmoser Date 2001-07-14 Time 10:53 Rev Time 0.33
Received By hmoser Date 2001-07-14 Time 10:53 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-08-18 Cont ID  
Sent By jleech Date 2001-08-18 Time 11:31 Rev Time 0.25
Received By jleech Date 2001-08-18 Time 11:31 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-07-10 Cont ID  
Sent By kstevens Date 2001-07-10 Time 09:44 Rev Time 0.50
Received By kstevens Date 2001-07-10 Time 09:44 Sent To  
Notes
2001-07-10 00:00:00FAILED
  
 1) PAGES 1A & 2 GENERAL NOTES #11 CHANGE
 TO READ FHA 1998 DESIGN MANUAL.
  
 2) MODEL 1572 (L) & (R), M/B SHOWS 1'7"
 TO CENTER OF W/C, AND IT SHOULD BE 1'6"
 ALSO SHOW CLEAR FLOOR SPACE FOR LAV.
  
 3) IN BATH 2 SHOW CLEAR FLOOR SPACE FOR
 W/C AND LAV. PAGES 1A & 1B.
  
 4) MODEL 1409 (L) & (R), M/B SHOWS 1'7"
 TO CENTER OF W/C, AND IT SHOULD BE 1'6"
 ALSO SHOW CLEAR FLOOR SPACE FOR LAV.
  
 5) BATH 2 SHOWS 2'8" OPENING FOR W/C.
 2'9" MINIMUM SPACE REQUIRED FOR W/C.
 ALSO SHOW CLEAR FLOOR SPACE FOR W/C AND
 LAV. PAGES 1A & 1B.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT. 8377

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status F Date 2001-09-17 Cont ID  
Sent By jgomez Date 2001-09-17 Time 19:02 Rev Time 0.33
Received By jgomez Date 2001-09-17 Time 19:02 Sent To  
Notes
2001-09-17 00:00:00TRUSS DRAWINGS CHECKLIST:
  
 1-TRUSS LAYOUT TO HAVE THE ENGINEER'S
 INFORMATION AS REQUIRED BY CHAPTER
 471 OF FLORIDA STATUTES WHEN SUBMITT'G
 INFORMATION FOR PUBLIC RECORDS.
  
 2-REVIEW STAMP USED BY PROFESSIONAL
 DESIGNER OF RECORD DOESN'T IDENTIFY
 THE NAME OF THE COMPANY WHO REVIEW
 THE TRUSS DRAWINGS. PROVIDE THIS
 INFORMATION.
  
 3-TRUSS ENGINEER TO HAVE ORIGINAL
 SIGNATURE AS REQUIRED BY CHAPTER 471
 OF FLORIDA STATUTES.
  
 4-PROVIDE TWO PACKAGES OF TRUSS DRAWINGS
  
  
  
  
  
 NOTES:
 -DRAWINGS TO BE FILED UNDER PERMIT #
 01070113.
  
 -THESE COMMENTS APPLY TO PERMIT #S:
 01070113, 01070110, 01070104 AND
 01070106.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2001-08-24 Cont ID  
Sent By jgomez Date 2001-08-24 Time 17:56 Rev Time 1.00
Received By jgomez Date 2001-08-24 Time 17:56 Sent To  
Notes
2001-08-24 00:00:00APPROVED WITH PROVISO:
 1-FLOOD ZONE AO. WILL NEED TO PROVIDE
 THE ELEVATION CERTIFICATE.
 2-STORM SHUTTERS INFORMATION WAS NOT
 PROVIDED. THEREFORE, PROVIDE COMPLETE
 INFORMATION UNDER A SEPARATE PERMIT.
 3-PROVIDE THE APPROPRIATE PRODUCT
 APPROVAL FOR ANY SELECTED OPTION.
 4-PRELIMINARY SOIL TEST REPORT
 RECOMMENDS SOIL TEST FOR EACH STRUCTU-
 RE. FOLLOW THESE RECOMMENDATIONS AND
 PROPER PREPARATION OF SOIL.
 5-PROVIDE THE DESIGN CERTIFICATION FOR
 BUILDING CODE COMPLIANCE FORM.
  
  
  
  
 NOTES:
 -DRAWINGS TO BE FILED UNDER PERMIT #
 01070113.
  
 -THESE COMMENTS APPLY TO PERMIT #S:
 01070113, 01070110, 01070104 AND
 01070106.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2001-07-25 Cont ID  
Sent By jgomez Date 2001-07-25 Time 12:07 Rev Time 1.00
Received By jgomez Date 2001-07-25 Time 12:07 Sent To  
Notes
2001-07-25 00:00:00CHECKLIST:
 1-FAILED BY PLUMBING. SEE COMMENTS.
 2-FILE NOTICE OF COMMENCEMENT.
 3-FLOOD ZONE AO. WILL NEED ELEVATION
 CERTIFICATE.
 4-PROVIDE COMPLETE INFORMATION FOR STORM
 PANELS OR APPLY FOR SEPARATE PERMIT.
 5-CLEARLY INDICATE ON PLANS WHICH OPTION
 IS GOING TO BE BUILT. CROSS OUT THE
 ONES THAT DON'T APPLY.
 -PROVIDE THE CORRESPONDING PRODUCT
 APPROVALS FOR SELECTED OPTIONS.
 6-PRELIMINARY SOIL TEST RECOMMENDS SOIL
 TEST FOR EACH STRUCTURE. FOLLOW THESE
 RECOMMENDATIONS AND PROPER PREPARATION
 OF SOIL.
 7-ENERGY CALCULATIONS AND ARCHITECTURAL
 PLANS DON'T MATCH. HOT WATER HEATER
 CAPACITY IS 40 GALS OR 50 GALS. REVISE
 EITHER ONE TO MATCH.
 8-PROVIDE THE DESIGN CERTIFICATION FOR
 BUILDING CODE COMPLIANCE FORM.
 9-DESIGNER OF RECORD TO REVIEW ALL TRUSS
 DRAWINGS (AFTER THEY ARE REVISED FOR
 ASCE 7-95 FOR 145MPH WIND LOAD) AND
 SPECIFY CONNECTORS THAT WILL RESIST
 THE ENGINEERED CALCULATED LOADS FOR
 EACH TRUSS.
  
  
  
  
 NOTES:
 -THESE COMMENTS APPLY FOR PERMIT #S:
 01070113, 01070110, 01070104 AND
 01070106.
 -ALL DRAWINGS WILL BE FILED UNDER
 PERMIT #01070113.

Review Stop Z ZONING
Rev No 1 Status P Date 2001-07-10 Cont ID  
Sent By sgraham Date 2001-07-10 Time 07:49 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***