Plan Review Details - Permit 01070110
Plan Review Stops For Permit 01070110
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-07-18 Cont ID  
Sent By dpalmer Date 2001-07-18 Time 07:02 Rev Time 0.00
Received By dpalmer Date 2001-07-18 Time 07:02 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2001-08-20 Cont ID  
Sent By mcarsill Date 2001-08-20 Time 09:07 Rev Time 0.00
Received By mcarsill Date 2001-08-20 Time 09:07 Sent To  
Notes
2001-08-20 00:00:001) BUILDING ADDRESSES REQUIRED.
 2) WET FIRE HYDRANTS ARE REQUIRED PRIOR
 TO, DURING AND AFTER CONSTRUCTION.
 3) ELECTRIC POWERED SMOKE DETECTORS ARE
 REQUIRED. WHEN ACTIVATED, THESE DEVICES
 ARE TO BE AUDIBLE IN THE SLEEPING ROOMS
 OF THAT UNIT.
 4) PORTABLE FIRE EXTINGUISHERS REQUIRED.
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-07-14 Cont ID  
Sent By hmoser Date 2001-07-14 Time 10:55 Rev Time 0.33
Received By hmoser Date 2001-07-14 Time 10:55 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-08-18 Cont ID  
Sent By jleech Date 2001-08-18 Time 11:32 Rev Time 0.12
Received By jleech Date 2001-08-18 Time 11:32 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-07-10 Cont ID  
Sent By kstevens Date 2001-07-10 Time 09:52 Rev Time 0.50
Received By kstevens Date 2001-07-10 Time 09:52 Sent To  
Notes
2001-07-10 00:00:00FAILED
  
 1) PAGES 1A & 2 GENERAL NOTES #11 CHANGE
 TO READ FHA 1998 DESIGN MANUAL.
  
 2) MODEL 1572 (L) & (R), M/B SHOWS 1'7"
 TO CENTER OF W/C, AND IT SHOULD BE 1'6"
 ALSO SHOW CLEAR FLOOR SPACE FOR LAV.
  
 3) IN BATH 2 SHOW CLEAR FLOOR SPACE FOR
 W/C AND LAV. PAGES 1A & 1B.
  
 4) MODEL 1409 (L) & (R), M/B SHOWS 1'7"
 TO CENTER OF W/C, AND IT SHOULD BE 1'6".
 ALSO SHOW CLEAR FLOOR SPACE FOR LAV.
  
 5) BATH 2 SHOWS 2'8" OPENING FOR W/C.
 2'9" MINIMUM SPACE REQUIRED FOR W/C.
 ALSO SHOW CLEAR FLOOR SPACE FOR W/C AND
 LAV. PAGES 1A & 1B.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT. 8377

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2001-08-24 Cont ID  
Sent By jgomez Date 2001-08-24 Time 18:09 Rev Time 1.00
Received By jgomez Date 2001-08-24 Time 18:09 Sent To  
Notes
2001-08-24 00:00:00APPROVED WITH PROVISO:
 SEE NOTES ON PERMIT #01070113.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2001-07-25 Cont ID  
Sent By jgomez Date 2001-07-25 Time 14:30 Rev Time 1.00
Received By jgomez Date 2001-07-25 Time 14:29 Sent To  
Notes
2001-07-25 00:00:00CHECKLIST:
 SEE COMMENTS ON PERMIT #01070113.

Review Stop Z ZONING
Rev No 1 Status P Date 2001-07-10 Cont ID  
Sent By sgraham Date 2001-07-10 Time 07:46 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***