Plan Review Details - Permit 01061269
Plan Review Stops For Permit 01061269
Review Stop E ELECTRICAL
Rev No 4 Status P Date 2002-12-11 Cont ID  
Sent By dpalmer Date 2002-12-11 Time 13:21 Rev Time 0.50
Received By dpalmer Date 2002-12-11 Time 13:20 Sent To  
Notes
2002-12-11 00:00:00REDLINED 400A METERCAN.

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2002-11-21 Cont ID  
Sent By dpalmer Date 2002-11-21 Time 14:11 Rev Time 0.50
Received By dpalmer Date 2002-11-21 Time 14:11 Sent To  
Notes
2002-11-21 00:00:00************* UNSAT ************
  
 1)NOTE: PLEASE NOTE, UNDER FS. 471.025
 ALL CHANGES DONE TO PLANS THAT ARE SIGN-
 ED AND SEALED, MUST BE DONE BY THE
 ENGINEER OF RECORD.
 PLEASE NOTE RISER DIAGRAM HAS BEEN
 CHANGED.
  
 PLEASE SUBMIT THE BAQOVE INFORMATION
 FOR REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2001-09-18 Cont ID  
Sent By dpalmer Date 2001-09-18 Time 11:41 Rev Time 0.00
Received By dpalmer Date 2001-09-18 Time 11:41 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-07-18 Cont ID  
Sent By dpalmer Date 2001-07-18 Time 13:02 Rev Time 0.00
Received By dpalmer Date 2001-07-18 Time 13:02 Sent To  
Notes
2001-07-18 00:00:00************ REVISION/PROVISO *********
  
 1)NOTE: PLEASE SUBMIT COMPLETE PANEL
 SCHEDULES FOR PANELS BEFORE FINAL.
  
 2) NOTE: PLEASE LIST THE REQ`D BATH(S)
 CIRCUIT(S) PER 210-11-C-3.
 MUST BE 20A AND #12AWG.
  
 3) NOTE: SMOKE DETECTORS ARE REQUIRED
 INSIDE AND OUTSIDE ALL SLEEPING ROOMS.
 ALSO ON EACH LEVEL OF A MULTI-LEVEL
 DWELLING UNIT. ROOMS WITH BATHS AND OR
 CLOSETS ARE CONSIDERED SLEEPING ROOMS.
 PER NFPA-72 2-2.1.1.1.
  
 4)NOTE: PLEASE SHOW ALL OUTLETS SERVING
 KITCHEN COUNTERSPACE AS GFI/GFI PROTECT-
 -ED PER 210-8-A-6.
  
 PLEASE SUBMIT THE ABOVE INFORMATION RE-
 -DRAWN BEFORE FINAL! IF THERE ARE ANY
 QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2002-05-18 Cont ID  
Sent By hmoser Date 2002-05-18 Time 07:34 Rev Time 0.50
Received By hmoser Date 2002-05-18 Time 07:34 Sent To  
Notes
2002-05-18 00:00:00PROVISO
 NEED MANUFACTURER'S INSTALLATION
 INSTRUCTIONS FOR COOKTOP FOR ROUGH
 INSPECTIONS
 PLAN REVIEW BY HAROLD MOSER
 [561]659-8096 EXT 8390

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2002-05-15 Cont ID  
Sent By hmoser Date 2002-05-15 Time 20:16 Rev Time 0.50
Received By hmoser Date 2002-05-15 Time 20:16 Sent To  
Notes
2002-05-15 00:00:00PLAN DENIED
 NO DUCT SIZE FOR RETURN AIR ON
 AIRHANDLER# 2
 PLAN REVIEW BY HAROLD MOSER
 [561]659-8096 EXT 8390

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-09-18 Cont ID  
Sent By hmoser Date 2001-09-18 Time 18:10 Rev Time 0.75
Received By hmoser Date 2001-09-18 Time 18:09 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-07-14 Cont ID  
Sent By hmoser Date 2001-07-14 Time 10:02 Rev Time 0.75
Received By hmoser Date 2001-07-14 Time 10:03 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2001-09-22 Cont ID  
Sent By jleech Date 2001-09-22 Time 06:58 Rev Time 0.33
Received By jleech Date 2001-09-22 Time 06:58 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2001-09-10 Cont ID  
Sent By kstevens Date 2001-09-10 Time 16:03 Rev Time 1.00
Received By kstevens Date 2001-09-10 Time 16:03 Sent To  
Notes
2001-09-10 00:00:00DENIED..
  
 REFERENCE: SPC-94 - SGC-97
  
 1) PAGE P1 & P2, DRY HORIZONTAL VENT
 SHOWN AFTER BIDET IN BATH #1 NOT ALLOWED
 SPC-94 SECT. 906.2.
  
 2) PAGE P2, DRY HORIZONTAL VENT SHOWN
 AFTER BIDET IN BATH #2 NOT ALLOWED SPC-
 94 SECT. 906.2.
  
 3) PAGE P2, DRY HORIZONTAL VENT SHOWN
 AFTER SHOWER IN BATH #3 NOT ALLOWED SPC-
 94 SECT. 906.2.
  
 4) PAGE P2 SANT. RISER DIAGRAM, CLEAN
 OUT REQUIRED ON WASH MACHINE STACK AT 4'
 ABOVE FINISHED FLOOR. (SANT. RISER DIA-
 GRAM.
  
 5) PAGE P2, SANT. RISER DIAGRAM, A 3"
 VENT THROUGH THE ROOF IS REQUIRED PER
 SPC-94 SECT. 904.3.1. NONE IS SHOWN ON
 SANITARY RISER DIAGRAM.
  
 6) DEMO PERMITS REQUIRED.
  
 7) PAGE P2, WATER HEATER DETAIL, PAN
 DRAIN FOR WATER HEATER EMERGENCY PAN
 SHALL BE 1"
  
 8) SEPARATE PERMITS REQUIRED FOR GAS AND
 IRRIGATION. PLUMBING CONTRACTOR SHALL
 CUT INTO WATER SERVICE AND LEAVE A VALVE
 AND AN ADAPTOR FOR IRRIGATION IF NONE IS
 AVAILABLE.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT. 8377

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-07-03 Cont ID  
Sent By kstevens Date 2001-07-03 Time 10:49 Rev Time 0.75
Received By kstevens Date 2001-07-03 Time 10:49 Sent To  
Notes
2001-07-03 00:00:00FAILED...
  
 1) DEMO PERMITS REQUIRED
  
 2) COVER SHEET SHOWS PLUMBING PAGES P-1,
 P-2, AND P-3. NO P-3 SHEET FOUND. PLEASE
 UBMIT FULL SET OF PLANS.
  
 3) DRY HORIZONTAL VENT SHOWN AFTER BIDET
 IN BATH #1 NOT ALLOWED PER SPC-94 SECT.
 906.2
  
 4) DRY HORIZONTAL VENT SHOWN AFTER
 SHOWER IN BATH #2 NOT ALLOWED PER SPC-94
 SECT. 906.2
  
 5) DRY HORIZONTAL VENT SHOWN AFTERSHR
 IN BATH #3 NOT ALLOWED PER SPC-94 SECT.
 906.2
  
 6) CLEAN OUT REQUIRED ON WASH MACHINE
 STACK AT 4' ABOVE FLOOR.
  
 7) PAN DRAIN FOR WATER HEATER EMERGENCY
 PAN TO BE 1".
  
 8) 3" VENT THROUGH ROOF REQUIRED PER SPC
 -94 SECT. 904.3.1. NONE SHOWN ON SANT.
 RISER DIAGRAM.
  
 9) SEPARATE GAS PERMIT REQUIRED. SEE
 ATTACHED GAS PERMIT APPLICATION REQUIRE-
 MENTS SHEET FOR REQUIRED INFORMATION.
  
 10) BACKFLOW REQUIRED FOR POOL
  
 11) SEPARATE PERMIT FOR IRRIGATION.
 PLUMBING CONTRACTOR CUT INTO WATER
 SERVICE AND LEAVE A VALVE AND AN ADAPTOR
 FOR IRRIGATION IF NONE IS AVAILABLE.
  
 12) SANITARY RISER DIAGRAM SHOWS A LAV
 NEXT TO THE DISHWASHER. PLEASE CLARIFY
 IF THAT IS A LAV OR KIT. SINK.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT. 8377

Review Stop R ROOF PLAN REVIEW
Rev No 4 Status F Date 2002-04-09 Cont ID  
Sent By jgomez Date 2002-04-09 Time 10:07 Rev Time 3.00
Received By jgomez Date 2002-04-08 Time 17:32 Sent To  
Notes
2002-04-08 00:00:00CHECKLIST:
 1-SPECIFY SIZE AND TYPE OF WINDOW TYPE E
 TO VERIFY FOR EGRESS REQUIREMENTS OF
 SECTION 1005.4 SBC 1997.
 2-CLEARLY SPECIFY ON PLANS AREAS TO HAVE
 SAFETY GLASS AS REQUIRED BY SECTION
 2405.2 SBC 1997. SEE PLANS.
 3-PROVIDE ALL INFORMATION REQUIRED ON
 PROVISO DATED 9-10-01 TO AVOID DELAYS.
 4-NEED PANEL ENCLOSURE DETAILS AT LOGGIA
 NOTE: ABOVE ITEMS WHERE REQUESTED ON
 PREVIOUS REVISION CHECKLIST & WERE NOT
 ADDRESSED. MULTIPLE RE-SUBMITTAL FEES
 WILL BE CHARGED WHEN RE-SUBMITTING.
  
 5-TRUSS DRAWINGS CHECKLIST:
 A)FLOOR TRUSSES ARE DESIGNED USING THE
 WRONG LOADING. SEE STRUCTURAL DWGS.
 CLARIFY WHY ARE THERE UPLIFT LOADS ON
 FLOOR TRUSSES?
 ALSO, FLOOR TRUSSES ARE DESIGNED WITH
 ROOF TRUSSES DESIGN CRITERIA. REVISE.
 B)UPDATE/REVISE CODE USED. SPECIFY SBC
 1997 FOR 110MPH OR ASCE 7-95 FOR 140
 MPH (NOT ASCE 7-93 FOR 110MPH).
 C)TRUSS LAYOUT TO BE SIGNED, SEALED AND
 DATED BY TRUSS ENGINEER AND PROVIDE
 ALL ENGINEER'S INFORMATION AS REQUIRED
 BY CHAPTER 471 FLORIDA STATUTES WHEN
 SUBMITTING DRAWINGS FOR PUBLIC RECORDS
 D)ENGINEERED TRUSSES TO HAVE ORIGINAL
 SIGNATURE. CHAPTER 471 FLORIDA STATUTE
 E)THERE ARE SOME ENGINEERED TRUSSES THAT
 ARE MISSING ON THE TRUSS LAYOUT.
 CLEARLY IDENTIFY ALL TRUSSES ON LAYOUT
 F)ENGINEER OF RECORD TO SPECIFY ANCHOR
 THAT WILL RESIST THE UPLIFT LOADS
 CALCULATED ON THE ENGINEERED TRUSSES
 T11 AND T12. SEE ENGINEERED TRUSSES.
 G)TRUSS T6 IS DESIGNED TO BEAR AT THREE
 POINTS, WHILE STRUCTURAL DWGS SHOW
 BEARING AT BOTH ENDS OF TRUSS. REVISE
 EITHER THE ENGINEERED TRUSS OR THE
 STRUCTURAL DWGS TO MATCH.
  
 NOTE: SEE COPIES OF PREVIEWS COMMENTS
 ATTACHED.

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status F Date 2001-12-14 Cont ID  
Sent By jgomez Date 2001-12-14 Time 15:59 Rev Time 0.50
Received By jgomez Date 2001-12-14 Time 15:59 Sent To  
Notes
2001-12-14 00:00:00REVISION CHECKLIST:
 1-WINDOWS AT BEDROOM #1 DON'T COMPLY
 WITH SECTION 1005.4SBC 1997 FOR
 EGRESS REQUIREMENTS. MINIMUM CLEAR
 WIDTH AND MINIMUM TOTAL CLEAR OPENING.
 *PROVIDE CUT SHEETS FOR CASEMENT
 WINDOWS TO BE USED TO ASSURE COMPLIAN-
 CE WITH MINIMUM SIZES REQUIRED.
 2-SPECIFY ON PLANS AREAS TO HAVE SAFETY
 GLASS AS REQUIRED BY SEC. 2405.2 SBC.
 SEE PLANS FOR COMMENTS.
 3-REVISE ELECTRICAL AND PLUMBING PLANS
 AS REQUIRED TO MATCH REVISION.
 4-PROVIDE COMPLETE DETAILS AND SPECS
 FOR ACCORDION LOUVERED PANEL ENCLOSURE
 AT LOGGIA. SEC. 1606 SBC 1997 AND
 SEC. 104.2.2 CITY AMENDMENTS TO SBC/97
 5-PROVIDE ALL INFORMATION REQUIRED ON
 PROVISO DATED 9-10-01 TO AVOID ANY
 DELAYS OR CONFLICTS.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2001-09-10 Cont ID  
Sent By jgomez Date 2001-09-10 Time 10:39 Rev Time 3.50
Received By jgomez Date 2001-09-10 Time 10:39 Sent To  
Notes
2001-09-10 00:00:00APPROVED WITH PROVISO:
 1-FLOOD ZONE A5. NEED TO PROVIDE THE
 ELEVATION CERTIFICATE.
 2-SPECIFY SIZE OF ATTIC VENTILATION.
 SECTION 2309.7 SBC 1997.
 3-SPECIFY MATERIAL AND LOCATION OF
 DRAFSTOPPING AT SECOND FLOOR FRAMING
 PLAN. SEC. 2305.2.2 SBC 1997.
 4-PROVIDE PRODUCT APPROVAL FOR:
 A)FRENCH DOORS (LEGIBLE DRAWINGS).
 B)CASEMENT WINDOWS.
 C)FIXED RECTANGULAR WINDOWS.
 D)ROUND WINDOWS.
 E)ENTRY DOOR AS SHOWN ON ELEVATION.
 F)FLAT ROOF SYSTEM.
 G)VINYL SIDING.
 5-STORM SHUTTERS TO BE DONE UNDER A
 SEPARATE PERMIT.
 6-SPECIFY SAFETY GLASS WHERE REQUIRED.
 SEE PLANS. SEC 2405.2 SBC 1997.
 7-PROVIDE COMPLETE STRUCTURAL SECTION/
 DETAIL AT ELEVATOR SHAFT.
 -SPECIFY WHERE IS THE ELEVATOR MACHINE
 ROOM?.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2001-08-10 Cont ID  
Sent By jgomez Date 2001-08-10 Time 18:37 Rev Time 5.00
Received By jgomez Date 2001-08-10 Time 18:37 Sent To  
Notes
2001-08-10 00:00:00CHECKLIST:
 1-PAY IMPACT FEES TO PALM BEACH COUNTY.
 BRING STAMPED DRAWINGS AND RECEIPT.
 2-PROVIDE UPDATED SURVEY WITH NEW LAYOUT
 SIGNED, SEALED AND DATED.
 3-ENTRY DOOR SHALL HAVE 32" MIN. CLEAR
 OPENING PER LEAF. TABLE 1004 SBC 1997.
 4-SIGN, SEAL AND DATE COVER SHEET.
 5-PROVIDE BUILDING AREA TABULATION.
 INCLUDING PORCHES AND BALCONIES.
 6-PROVIDE DESIGN PRESSURES CALCULATED AT
 ALL EXTERIOR OPENINGS. SEC 1606 SBC/97
 7-PROVIDE ATTIC ACCESS AT SECOND FLOOR
 ROOF AND ENTRY PORCH. SEC 2309.6 SBC
 8-SPECIFY ROOF VENTILATION AS REQUIRED
 BY SECTION 2309.7 SBC 1997.
 9-SPECIFY FIREBLOCKING AS REQUIRED BY
 SECTION 2305.1 SBC 1997.
 10-SPECIFY ON 2ND FLOOR FRAMING PLAN
 DRAFTSTOPPING MATERIAL AND LOCATION.
 SECTION 2305.2.2 SBC 1997.
 11-REVISE RAILING DETAILS AS REQUIRED TO
 COMPLY WITH SECTION 1015.3 SBC 1997.
 SEE COMMENTS ON PLANS.
 12-PROVIDE CONSTRUCTION DETAILS AT
 ARCHED OPENINGS. SECTION 104.2.2 OF
 CITY AMENDMENTS TO SBC 1997.
 13-SPECIFY FASTENING OF OUTLOOKERS.
 SECTION 1606 SBC 1997.
 14-PROVIDE SOIL TEST REPORT AS PER SEC.
 1804.2.7 AND TABLE 1804.2.7.3 OF
 CITY AMENDMENTS TO SBC 1997.
 15-PROVIDE PRODUCT APPROVALS FOR:
 A)FRENCH DOORS (IMPACT).
 B)CASEMENT WINDOWS (IMPACT).
 C)FIXED WINDOWS (IMPACT).
 D)ROUND WINDOWS (IMPACT).
 E)ENTRY DOORS AS SHOWN ON ELEVATIONS.
 F)ALUMINUM SHUTTERS (SEE ELEVATIONS).
 G)FLAT ROOF SYSTEMS.
 H)4" ICYNENE SPRAY INSULATION.
 I)VINYL SIDING.
  
 16-SEE PLANS FOR ADDITIONAL COMMENTS
 INCLUDING THOSE BY THE OTHER TRADES.

Review Stop Z ZONING
Rev No 1 Status P Date 2001-06-29 Cont ID  
Sent By sgraham Date 2001-06-29 Time 13:42 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***