Plan Review Details - Permit 01061260
Plan Review Stops For Permit 01061260
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2001-08-27 Cont ID  
Sent By dpalmer Date 2001-08-27 Time 13:44 Rev Time 0.00
Received By dpalmer Date 2001-08-27 Time 13:44 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2001-08-07 Cont ID  
Sent By dpalmer Date 2001-08-07 Time 17:00 Rev Time 0.00
Received By dpalmer Date 2001-08-07 Time 17:00 Sent To  
Notes
2001-08-07 00:00:00************** UNSAT *******************
  
 1)NOTE: PLEASE NOTE THAT PERMIT
 APPLICATION DOES NOT CORRELATE WITH
 PLANS SUBMITTED FOR REVIEW. PERMIT APP
 SAY NEW FLA
 ROOM AND SECOND FLOOR ADDITION ON HOUSE.
 YET PLANS SHOW COTTAGE. WHICH ONE?
  
  
 2)NOTE: PLEASE NOTE PLANS SHOW NEW
 SERVICE BEING INSTALLED. PLEASE CLARFIY
 HOW
 MAIN HOUSE IS BEING FED?
 GROUNDING ELECTRODE SYSTEM PER 250-50
 WIRE SIZES,
 CONDUIT SIZES,
 AIC RATINGS,
 ETC
  
 NOT ENOUGH ELECTRICAL DETAIL WAS
 SUBMITTED FOR FULL REVIEW OF PLANS.
 PLEASE ALSO HAVE PLANS REDRAWN FOR
 ELECTRICAL, THERE ARE WAY TOO MANY
 HANDWRITTEN CHANGES FOR FIRST TIME IN.
 PER COUNTY-WIDE AND CITY-WIDE
 ADMINISTRATIVE CODE.104.2
  
  
 4)NOTE: SMOKE DETECTORS ARE REQUIRED
 INSIDE AND OUTSIDE ALL SLEEPING ROOMS.
 ALSO ON EACH LEVEL OF A MULTI-LEVEL
 DWELLING UNIT. ROOMS WITH BATHS AND OR
 CLOSETS ARE CONSIDERED SLEEPING ROOMS.
 PER NFPA-72 2-2.1.1.1.
  
 5) NOTE: PLEASE LIST THE REQ`D BATH(S)
 CIRCUIT(S) PER 210-11-C-3.
 MUST BE 20A AND #12AWG.
  
 6) PLEASE NOTE MISSING OUTLET FOR A/C
 EQUIPMENT PER 210-63 OF NEC AND 309.1
 MECHANICAL CODE.
  
 PLEASE SUBMIT ALL THE ABOVE INFORMATION
 FOR REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2001-08-20 Cont ID  
Sent By pkrauss Date 2001-08-20 Time 08:25 Rev Time 0.35
Received By pkrauss Date 2001-08-20 Time 08:25 Sent To  
Notes
2001-08-20 00:00:00******************PROVISO***************
  
  
 PLANS INDICATE WALL UNIT FOR THE
 ADDITION.MECHANICAL PERMIT WILL BE REQ
 UIRED SHOULD A/C BE INSTALLED AT A LATER
 DATE.PLEASE SUBMIT PLANS AND ENERGY
 CALCULATIONS WITH PERMIT APPLICATION.
  
 IF YOU HAVE ANY QUESTIONS PLEASE
 CONTACT PATTY KRAUSS AT 659-8096 EXT.
 8388.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2001-08-04 Cont ID  
Sent By hmoser Date 2001-08-04 Time 09:14 Rev Time 0.33
Received By hmoser Date 2001-08-04 Time 09:14 Sent To  
Notes
2001-08-04 00:00:00PLAN DENIED
 NEED MORE INFORMATION NO EXISTING A/C
 #1 SIZE OF EXISTING A/C
 #2 SQ.FT.OF EXISTING HOUSE UNDER AIR
 #3 CAN EXISTING A/C HANDEL EXTRA 500
 C.F.M.
 #4 NOTES ON PAGE 2 OF PLANS CALL FOR
 NEW A/C
 PLAN REVIEW BY HAROLD MOSER
 [561]659-8096 EXT 8390

Review Stop P PLUMBING
Rev No 1 Status P Date 2001-07-30 Cont ID  
Sent By kstevens Date 2001-07-30 Time 19:52 Rev Time 0.50
Received By kstevens Date 2001-07-30 Time 19:52 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2001-08-31 Cont ID  
Sent By rmcdouga Date 2001-08-31 Time 12:26 Rev Time 1.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-08-31 00:00:00************BUILDING PROVISO************
  
 1)PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR STRUCTURAL WINDOW MULLIONS
 PRIOR TO INSTALLATION.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2001-08-29 Cont ID  
Sent By rmcdouga Date 2001-08-29 Time 10:05 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-08-29 00:00:00*************BUILDING UNSAT*************
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2)A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 3) THE ADDITION DOES NOT COMPLY WITH
 TABLE 600 OF THE 97 SBC. THE PERCENT OF
 WALL OPENINGS ALLOWED IS EXCEEDED ON THE
 WEST SIDE OF THE ADDITION. (33.2 SQFT OF
 OPENINGS IS ALLOWED.)
  
 4) PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR:
 - STRUCTURAL WINDOW MULLIONS
  
 5) PROVIDE INSTALLATION SCHEDULE AND
 INDICATE THE SPECIFIC TYPE ANCHOR TO BE
 USED FOR STORM PANELS.
  
 TRUSSES
 UNSAT
  
 1) THE TRUSS LAYOUT MUST BE REVIEWED
 AND APPROVED BY THE DESIGNER OF RECORD.
 (CONSULTING ENGINEER)
  
 2) EACH OF THE TRUSS DRAWINGS MUST HAVE
 THE WET SIGNATURE OF THE TRUSS ENGINEER
 IN ADDITION TO HIS SEAL AND THE DATE
 THAT THE SIGNATURE AND SEAL IS AFFIXED
 IMMEDIATELY UNDER THE SIGNATURE PER FAC
 61G15-23.002.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2001-08-07 Cont ID  
Sent By rmcdouga Date 2001-08-07 Time 09:34 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-08-07 00:00:00*************BUILDING UNSAT*************
  
 1)IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 3) PROVIDE ATTIC ACCESS AND ATTIC
 VENTILATION PER 97 SBC 2309.6 AND 2309.7
  
 4) PROVIDE FOUNDATION VENTILATION PER
 97 SBC 1804.6.2.1.
  
 5) PROVIDE DESIGN CERTIFICATION FOR
 BUILDING CODE COMPLIANCE FORM, COMPLETED
 SIGNED, SEALED AND DATED BY THE DESIGNER
 OF RECORD. AMENDMENTS 104.2.2
  
 6) INDICATE ROOF PITCH AND MEAN ROOF
 HEIGHT ON PLANS.
  
 7) INDICATE SPECIAL ROOF SHEATHING
 NAILING ZONES. AMENDMENTS 2306
  
 8) PROVIDE ROOF FRAMING PLAN INDICATING
 CONNECTORS TO BE USED AND UPLIFT TO BE
 RESISTED. THE SIMPSON H1 CONNECTOR
 INDICATED ON THE PLANS IS NOT SUFFICIENT
 TO ANCHOR GIRDER TRUSS H6.
  
 9) PROVIDE CLEAR SETS OF PLANS. IT IS
 DIFFICULT TO READ AND SEE DETAILS ON THE
 PLANS WITH ALL THE ADDITIONAL MARKING
 AND WRITING OVER THE DRAWINGS. CITY
 AMENDMENTS 104.2.1
  
 10) THE ADDITION DOES NOT COMPLY WITH
 TABLE 600 OF THE 97 SBC. THE PERCENT OF
 OPENINGS ALLOWED FOR A DISTANCE OF OVER
 3'TO 10'FROM THE PROPERTY LINE IS 20%
 OF THE WALL AREA (FROM FLOOR TO CEILING)
  
 11) PROVIDE THE DISTANCE BETWEEN THE
 ADDITION AND EXISTING COTTAGE. INDICATE
 THE NUMBERS AND SIZES OF ALL GLAZED
 OPENINGS IN WALL OF COTTAGE FACING
 ADDITION SO THAT TABLE 600 ALLOWED
 OPENING AREAS CAN BE CALCULATED.
  
 12)PROVIDE ENERGY CALCULATIONS AND
 EQUIPMENT SIZING CALCULATIONS (MANUAL J)
 AS REQUIRED BY THE 1997 FLORIDA ENERGY
 EFFICIENCY CODE FOR BUILDING
 CONSTRUCTION.
  
 13) INDICATE ON PLANS THAT SUITABLE
 BLOCKING OR BACKING WILL BE PROVIDED FOR
 THE INSTALLATION OF STORM PANELS.
  
 14) PROVIDE (2) COPIES OF INSTALLATION
 SCHEDULES AND KEY PLANS FOR STORM PANELS
 INDICATE THE SPECIFIC TYPES OF ANCHORS
 AND MOUNTING OPTION THAT IS TO BE USED.
  
 15) PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR:
 - STRUCTURAL WINDOW MULLIONS
 - SKYLITES IF BEING INSTALLED
  
 16) PROVIDE DETAILS FOR DECK AND STAIR
 GUARDRAILS ( HEIGHT, SPACE BETWEEN
 INTERMEDIATE RAILS, ETC.). 97 SBC 1015
  
 17) THE PROJECT DESCRIPTION ON THE
 PERMIT APPLICATION INDICATES A NEW ROOM
 OVER EXISTING LAUNDRY ROOM. SHOULD THIS
 STATE NEW ROOF? PLEASE CLARIFY.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202
  
 TRUSSES
 UNSAT
  
 1) THE TRUSS LAYOUT IS REQUIRED TO BE
 WET SIGNED, SEALED AND DATED BY THE
 TRUSS ENGINEER.
  
 2) THE TRUSS LAYOUT MUST BE REVIEWED AND
 APPROVED BY THE DESIGNER OF THE
 STRUCTURE AND SIGNED BY HIM OR HER.
  
 3) ALL OF THE TRUSS DRAWINGS ARE
 REQUIRED TO BE SIGNED, SEALED AND DATED
 BY THE TRUSS ENGINEER.

Review Stop Z ZONING
Rev No 1 Status P Date 2001-07-30 Cont ID  
Sent By sgraham Date 2001-07-30 Time 10:56 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***