Plan Review Details - Permit 01061037
Plan Review Stops For Permit 01061037 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2001-08-27 |
|
|
Cont ID |
|
Sent By |
lsmith |
Date |
2001-08-27 |
Time |
07:51 |
Rev Time |
0.50 |
Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2001-06-25 |
|
|
Cont ID |
|
Sent By |
lsmith |
Date |
2001-06-25 |
Time |
07:18 |
Rev Time |
0.25 |
Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-06-25 00:00:00 | NO SEALED DRAWINGS; NO CONTRACT TO | | VERIFY VALUE LS |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2001-08-24 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-08-24 |
Time |
10:38 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-08-24 |
Time |
10:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2001-06-24 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-06-24 |
Time |
10:11 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-06-24 |
Time |
10:11 |
Sent To |
|
|
Notes |
2001-06-24 00:00:00 | ****************** UNSAT ************** | | | | 1)NOTE: PLEASE NOTE THAT UNDER F.A.C | | AND F.S. 61G15-23.002 ALL PLANS THAT | | ARE DONE BY AN ENGINEER ARE TO HAVE | | TITLE BLOCKS CONTAINING ALL THE INFORMAT | | ON ENG OF RECORD. | | ALL MUST BE SIGNED, DATED AND SEALED. | | SIGNATURE AND DATE MUST BE ORIG WET SIG. | | | | | | 2)NOTE: PLEASE NOTE THAT LOAD CALCULATIO | | NS NEED TO BE SUBMITTED WITH ALL NEW | | LOAD S ADDED TO EXISTING ELETCRICAL | | SERVICE. PLEASE ALSO SHOW SIZEAND LOAD | | ON EXIT SERVICE.215-5 | | | | 3)NOTE: PLEASE NOTE THAT FEED TO0 NEW | | PANEL SHOWS 3-#6`S AND NO EQUIPMENT | | GROUNDING CONDUCTOR. PLEASE CLARIFY | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2001-08-25 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2001-08-25 |
Time |
11:32 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2001-08-25 |
Time |
11:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2001-07-12 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2001-07-12 |
Time |
12:00 |
Rev Time |
0.33 |
Received By |
kstevens |
Date |
2001-07-12 |
Time |
12:00 |
Sent To |
|
|
Notes |
2001-07-12 00:00:00 | FAILED | | | | 1) PLEASE SEE COMMENT #1 OF ELECTRICAL | | PLAN REVIEW. (TITLE BLOCK REQUIRED) | | | | 2) BYPASS REQUIRED FOR POOL HEATER. NOT | | SHOWN ON PIPING DIAGRAM. | | | | 3) 3 RETURNS MINIMUM ARE REQUIRED, NONE | | SHOWN ON PAGE 1 OF 1. PLEASE SHOW THREE | | RETURNS ON PLANS. | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT. 8377 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2001-06-21 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2001-06-21 |
Time |
11:15 |
Rev Time |
0.25 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
|