Plan Review Details - Permit 01061037
Plan Review Stops For Permit 01061037
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2001-08-27 Cont ID  
Sent By lsmith Date 2001-08-27 Time 07:51 Rev Time 0.50
Received By lsmith Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2001-06-25 Cont ID  
Sent By lsmith Date 2001-06-25 Time 07:18 Rev Time 0.25
Received By lsmith Date   Time   Sent To  
Notes
2001-06-25 00:00:00NO SEALED DRAWINGS; NO CONTRACT TO
 VERIFY VALUE LS

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2001-08-24 Cont ID  
Sent By dpalmer Date 2001-08-24 Time 10:38 Rev Time 0.00
Received By dpalmer Date 2001-08-24 Time 10:38 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2001-06-24 Cont ID  
Sent By dpalmer Date 2001-06-24 Time 10:11 Rev Time 0.00
Received By dpalmer Date 2001-06-24 Time 10:11 Sent To  
Notes
2001-06-24 00:00:00****************** UNSAT **************
  
 1)NOTE: PLEASE NOTE THAT UNDER F.A.C
 AND F.S. 61G15-23.002 ALL PLANS THAT
 ARE DONE BY AN ENGINEER ARE TO HAVE
 TITLE BLOCKS CONTAINING ALL THE INFORMAT
 ON ENG OF RECORD.
 ALL MUST BE SIGNED, DATED AND SEALED.
 SIGNATURE AND DATE MUST BE ORIG WET SIG.
  
  
 2)NOTE: PLEASE NOTE THAT LOAD CALCULATIO
 NS NEED TO BE SUBMITTED WITH ALL NEW
 LOAD S ADDED TO EXISTING ELETCRICAL
 SERVICE. PLEASE ALSO SHOW SIZEAND LOAD
 ON EXIT SERVICE.215-5
  
 3)NOTE: PLEASE NOTE THAT FEED TO0 NEW
 PANEL SHOWS 3-#6`S AND NO EQUIPMENT
 GROUNDING CONDUCTOR. PLEASE CLARIFY
  
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-08-25 Cont ID  
Sent By jleech Date 2001-08-25 Time 11:32 Rev Time 0.33
Received By jleech Date 2001-08-25 Time 11:32 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-07-12 Cont ID  
Sent By kstevens Date 2001-07-12 Time 12:00 Rev Time 0.33
Received By kstevens Date 2001-07-12 Time 12:00 Sent To  
Notes
2001-07-12 00:00:00FAILED
  
 1) PLEASE SEE COMMENT #1 OF ELECTRICAL
 PLAN REVIEW. (TITLE BLOCK REQUIRED)
  
 2) BYPASS REQUIRED FOR POOL HEATER. NOT
 SHOWN ON PIPING DIAGRAM.
  
 3) 3 RETURNS MINIMUM ARE REQUIRED, NONE
 SHOWN ON PAGE 1 OF 1. PLEASE SHOW THREE
 RETURNS ON PLANS.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT. 8377

Review Stop Z ZONING
Rev No 1 Status P Date 2001-06-21 Cont ID  
Sent By sgraham Date 2001-06-21 Time 11:15 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***