Plan Review Details - Permit 01060846
Plan Review Stops For Permit 01060846
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-01-07 Cont ID  
Sent By btrobaug Date 2002-01-07 Time 14:43 Rev Time 0.50
Received By btrobaug Date 2002-01-07 Time 14:43 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-06-29 Cont ID  
Sent By dpalmer Date 2001-06-29 Time 10:11 Rev Time 0.00
Received By dpalmer Date 2001-06-29 Time 10:11 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2001-09-04 Cont ID  
Sent By mcarsill Date 2001-09-04 Time 13:29 Rev Time 0.00
Received By mcarsill Date 2001-09-04 Time 13:28 Sent To  
Notes
2001-09-04 00:00:001) WET FIRE HYDRANTS ARE REQUIRED PRIOR
 TO,DURING AND AFTER CONSTRUCTION.
 2) BUILDING ADDRESSES REQUIRED.
 3) ELECTRIC POWERED SMOKE DETECTORS ARE
 REQUIRED. WHEN ACTIVATED, THESE DEVICES
 ARE TO BE AUDIBLE IN THE SLEEPING ROOMS
 OF THAT UNIT.
 4) PORTABLE FIRE EXTINGUISHERS REQUIRED.
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-06-27 Cont ID  
Sent By hmoser Date 2001-06-27 Time 19:18 Rev Time 0.33
Received By hmoser Date 2001-06-27 Time 19:18 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-09-05 Cont ID  
Sent By kstevens Date 2001-09-05 Time 09:37 Rev Time 0.33
Received By kstevens Date 2001-09-05 Time 09:36 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-06-27 Cont ID  
Sent By kstevens Date 2001-06-27 Time 09:20 Rev Time 0.50
Received By kstevens Date 2001-06-27 Time 09:03 Sent To  
Notes
2001-06-27 00:00:00FAILED
  
 1) PAGE 1A & PAGE 2 GENERAL NOTES #11.
 CHANGE TO READ FHA 1998 DESIGN MANUAL.
  
 2) MODEL 1572 (L) & (R), M/B SHOWS 1'7"
 TO CENTER OF W/C, AND IT SHOULD BE 1'6"
 ALSO SHOW CLEAR FLOOR SPACE FOR LAV.
  
 3) IN BATH 2 SHOW CLEAR FLOOR SPACE FOR
 W/C AND LAV. PAGES 1A & 1B.
  
 4) MODEL 1409 (L) & (R) , M/B SHOWS 1'7"
 TO CENTER OF W/C, AND IT SHOULD BE 1'6"
 ALSO SHOW CLEAR FLOOR SPACE FOR LAV.
  
 5) BATH SHOWS 2'8" OPENING FOR W/C.
 2'9"" MINIMUM SPACE REQUIRED FOR W/C.
 ALSO SHOW CLEAR FLOOR SPACE FOR W/C AND
 LAV. PAGES 1A & 1B.
  
 REVIEW BY KEN STEVENS
 (561) 569-8096 EXT. 8377

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2001-08-31 Cont ID  
Sent By rmcdouga Date 2001-08-31 Time 11:39 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-08-31 00:00:00************BUILDING PROVISO************
  
 1)PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR:
 - GARAGE DOORS (PRIOR TO INSTALLATION)
  
 2) STRUCTURE IS LOCATED IN AN AO FLOOD
 ZONE AN ELEVATION CERTIFICATE IS
 REQUIRED.
  
 3) IF OPTIONS ARE USED, THE CORRESPOND-
 ING PRODUCT APPROVALS MUST BE SUBMITTED.
 MANUFACTURER'S SPECIFICATIONS AND LIST-
 ING INFORMATION IS REQUIRED IF OPTIONAL
 BBQ IS INSTALLED.
  
 4) PROVIDE PRODUCT APPROVALS, KEY PLAN
 AND INSTALLATION SCHEDULE FOR STORM
 PANELS UNDER A SEPARATE PERMIT.
  
  
 TRUSSES
 UNSAT
  
 1) THE TRUSS ENGINEERS TITLE BLOCK (NAME
 ADDRESS AND NUMBER) IS REQUIRED ON THE
 TRUSS LAYOUT.
  
 2) THE TRUSS DRAWINGS REFERENCE
 INCORRECT DESIGN CRITERIA (ASCE 7-93),
 THE PROPER CRITERIA IS ASCE 7-95 WITH
 (145 MPH WINDLOAD) OR 1997 SBC SECTION
 1606 WITH (110 MPH WINDLOAD). PLEASE
 CORRECT.
  
 3) THE TRUSS DETAILS FOR BRACING, GABLES
 OVERHANG, PIGGYBACKS, ETC.
  
 4) TRUSS DRAWINGS TG33, T34 AND T35 ARE
 NOT SHOWN ON THE TRUSS LAYOUT AND THERE
 ARE NO TRUSS DRAWINGS FOR TRUSSES TG31,
 T32 AND T33 WHICH ARE INDICATED ON THE
 TRUSS LAYOUT. PLEASE CORRECT.
  
 5) THERE ARE TWO TRUSS DRAWINGS FOR THE
 SAME TRUSS WITH DIFFERENT UPLIFT VALUES
 LISTED. PLESAE CORRECT.
  
 NOTE:
 THESE COMMENTS APPLY TO THE FOLLOWING
 PERMIT NUMBERS: 01060846, 01060847,
 01060848, 01060849.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2001-07-24 Cont ID  
Sent By rmcdouga Date 2001-07-24 Time 11:47 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-07-24 00:00:00*************BUILDING UNSAT*************
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) THE PLANS INDICATE A 50 GALLON WATER
 HEATER AND THE ENERGY CALCULATIONS LIST
 A 40 GALLON WATER HEATER. PLEASE
 CORRECT.
  
 3)
 NOTE:IF OPTIONS ARE USED,THE CORRESPOND-
 ING PRODUCT APPROVALS MUST BE SUBMITTED.
 (DOUBLE FRENCH DOORS, FRENCH DOOR WITH
 SIDELITES) PROVIDE MANUFACTURERS SPECS
 AND LISTING INFORMATION IF OPTIONAL BBQ
 IS TO BE INSTALLED.
  
 4) PROVIDE (2) PRODUCT APPROVALS, KEY
 PLANS AND INSTALLATION SCHEDULES
 INDICATING THE SPECIFIC TYPES OF ANCHORS
 TO BE USED FOR STORM PANELS OR APPLY
 UNDER A SEPARATE PERMIT.
  
 5) STRUCTURE IS LOCATED IN AN AO FLOOD
 ZONE. AN ELEVATION CERTIFICATE WILL BE
 REQUIRED.
  
 6) PLEASE INDICATE THE MEAN ROOF HEIGHT
 OF THE STRUCTURE.
  
 7) PROVIDE A DESIGN COMPLIANCE FORM
 COMPLETED BY THE DESIGNER OF RECORD FOR
 THE STRUCTURE OR PROVIDE THE REQUIRED
 DESIGN PARAMETERS AND ASSUMPTIONS ON THE
 PLANS.
  
 8) THE UPLIFT VALUES FROM THE TRUSS
 DRAWINGS EXCEED THE ANCHOR CAPACITIES
 LISTED ON THE PLANS FOR THE FOLLOWING
 TRUSSES: T7,T8,T10,T11,T12,T13,T14,T15,
 T21,T22,T24,T25,T28,T29,T30,T31. PLEASE
 REVIEW AND CORRECT.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202
  
  
 TRUSSES
 UNSAT
  
 1) THE BLOCK STAMP OF THE TRUSS ENGINEER
 IS REQUIRED ON THE TRUSS LAYOUT.
  
 2) THE DETAIL DRAWINGS FOR BRACING,
 GABLES, OVERHANG, PIGGYBACK, ETC. ARE
 NOT SIGNED SEALED AND DATED BY THE
 ENGINEER. THESE DRAWINGS ALSO REFRENCE
 ASCE 7-93 AND 110 MPH WINDSPEED. THE 97
 SBC REQUIRES THE DESIGN CRITERIA TO
 COMPLY WITH SECTION 1606 (110 MPH WIND-
 LOAD) OR ASCE 7-95 (145 MPH WINDLOAD).
 PLEASE CORRECT.
  
 3) THE TRUSS LAYOUT LISTS ASCE 7-95 AND
 140 MPH. THE WINDLOAD FOR W.P.B. IS
 145 MPH BY LINEAR INTERPOLATION OF WIND
 SPEED CONTOUR LINES. PLEASE CORRECT.
  
 4) TRUSS DRAWINGS TG33,T34 AND T35 ARE
 NOT SHOWN ON TRUSS LAYOUT. THE LAYOUT
 HAS TG31, T32 AND T33 AND NO CORRESPOND-
 ING DRAWINGS. PLEASE CLARIFY. PLEASE
 PROVIDE AN INDEX OF TRUSS DRAWINGS.
  
  
 NOTE:
 THESE COMMENTS APPLY TO THE FOLLOWING
 PERMIT NUMBERS: 01060846, 01060847,
 01060848, 01060849.

Review Stop Z ZONING
Rev No 1 Status P Date 2001-06-20 Cont ID  
Sent By sgraham Date 2001-06-20 Time 12:13 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***