Plan Review Details - Permit 01060842
Plan Review Stops For Permit 01060842
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-02-05 Cont ID  
Sent By btrobaug Date 2002-02-05 Time 16:08 Rev Time 0.00
Received By btrobaug Date 2002-02-05 Time 15:17 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-06-24 Cont ID  
Sent By dpalmer Date 2001-06-24 Time 15:15 Rev Time 0.00
Received By dpalmer Date 2001-06-24 Time 15:15 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2001-09-04 Cont ID  
Sent By mcarsill Date 2001-09-04 Time 14:00 Rev Time 0.00
Received By mcarsill Date 2001-09-04 Time 14:00 Sent To  
Notes
2001-09-04 00:00:001) WET FIRE HYDRANTS ARE REQUIRED PRIOR
 TO, DURING AND AFTER CONSTRUCTION.
 2) BUILDING ADDRESSES REQUIRED.
 3) ELECTRIC POWERED SMOKE DETECTORS
 REQUIRED.
 4) PORTBALE FIRE EXTINGUISHERS REQUIRED.
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-06-21 Cont ID  
Sent By hmoser Date 2001-06-21 Time 19:22 Rev Time 0.33
Received By hmoser Date 2001-06-21 Time 19:22 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-09-06 Cont ID  
Sent By kstevens Date 2001-09-06 Time 13:05 Rev Time 0.33
Received By kstevens Date 2001-09-06 Time 13:04 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-06-21 Cont ID  
Sent By kstevens Date 2001-06-21 Time 17:50 Rev Time 0.33
Received By kstevens Date 2001-06-21 Time 17:50 Sent To  
Notes
2001-06-21 00:00:00REVIEW NOTES:FAILED
  
 1) PAGE 1A & PAGE 2 GENERAL NOTES #11
 CHANGE TO READ FHA 1998 DESIGN MANUAL.
  
 2) MODEL 1527 (L) & (R), M/B SHOWS 1'7"
 TO CENTER OF W/C, AND IT SHOULD BE 1'6"
 ALSO SHOW CLEAR FLOOR SPACE FOR LAV.
  
 3) IN BATH 2 SHOW CLEAR FLOOR SPACE FOR
 W/C AND LAV. PAGES 1A & 1B.
  
 4) MODEL 1409 (L) & (R), M/B SHOWS 1'7"
 TO CENTER OF W/C, AND IT SHOULD BE 1'6"
 ALSO SHOW CLEAR FLOOR SPACE FOR LAV.
  
 5) BATH 2 SHOWS 2'8" OPENING FOR W/C
 2'9" MINIMUM SPACE REQUIRED FOR W/C.
 ALSO SHOW CLEAR FLOOR SPACE FOR W/C AND
 LAV. PAGES 1A & 1B
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT. 8377

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2001-09-10 Cont ID  
Sent By rmcdouga Date 2001-09-10 Time 10:45 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-09-10 00:00:00************BUILDING PROVISO************
  
 1)PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR:
 - GARAGE DOORS (PRIOR TO INSTALLATION)
  
 2) STRUCTURE IS LOCATED IN AN AO FLOOD
 ZONE AN ELEVATION CERTIFICATE IS
 REQUIRED.
  
 3) IF OPTIONS ARE USED, THE CORRESPOND-
 ING PRODUCT APPROVALS MUST BE SUBMITTED.
 THE MANUFACTURER'S SPECIFICATIONS AND
 LISTING INFORMATION IS REQUIRED IF
 OPTIONAL BBQ IS INSTALLED.
  
 4) PROVIDE PRODUCT APPROVALS, KEY PLAN
 AND INSTALLATION SCHEDULE FOR STORM
 PANELS UNDER A SEPARATE PERMIT.
  
  
 TRUSSES
 UNSAT
  
 1)THE TRUSS ENGINEERS TITLE BLOCK (NAME,
 ADDRESS AND REGISTRATION NUMBER) IS
 REQUIRED ON THE TRUSS LAYOUT.
  
 2) THE (2) TRUSS LAYOUTS THAT WERE
 SUBMITTED ARE DIFFERENT. SOME OF THE
 TRUSSES ARE LABELED DIFFERENTLY. PLEASE
 SUBMIT (2) LAYOUTS THAT ARE THE SAME.
  
 3) THE TRUSS DRAWINGS ALSO DIFFER. ONE
 SET OF DRAWINGS INCORRECTLY REFERENCES
 ASCE 7-93 AND LISTS DIFFERENT MEAN ROOF
 HEIGHTS. THE OTHER SET ALSO HAS SOME
 DISCREPANCIES WITH MEAN ROOF HEIGHT AND
 REFERS TO 1997 SBCC. THE PROPER
 REFERENCE IS 1997 STANDARD BUILDING CODE
 (1997 SBC). PLEASE CORRECT.
  
 4) THE TRUSS DRAWINGS FOR GABLE DETAILS,
 OVERHANG, PIGGYBACKS, ETC. DO NOT HAVE
 THE EMBOSSED SEAL, WET SIGNATURE AND
 DATE BY THE TRUSS ENGINEER. THESE ALSO
 REFERENCE OUTDATED OR INCORRECT DESIGN
 CRITERIA (ASCE7-88, ASCE7-93, 1991 SBC).
 PLEASE CORRECT.
  
 NOTE:
 THESE COMMENTS APPLY TO THE FOLLOWING
 PERMIT NUMBERS: 01060842,01060843,
 01060844,01060845.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2001-07-25 Cont ID  
Sent By rmcdouga Date 2001-07-25 Time 14:01 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-07-25 00:00:00*************BUILDING UNSAT*************
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) THE PLANS INDICATE A 50 GAL. WATER
 HEATER AND THE ENERGY CALCULATIONS LIST
 A 40 GAL. WATER HEATER. PLEASE CORRECT.
  
 3) NOTE: IF OPTIONS ARE USED, THE
 CORRESPONDING PRODUCT APPROVALS MUST BE
 SUBMITTED FOR FRENCH DOORS. IF OPTIONAL
 BBQ IS TO BE INSTALLED, PROVIDE MANUFAC-
 TURERS SPECIFICATIONS AND LISTING INFOR-
 MATION.
  
 4) PROVIDE (2) PRODUCT APPROVALS, KEY
 PLANS AND INSTALLATION SCHEDULES
 INDICATING THE SPECIFIC TYPES OF ANCHORS
 TO BE USED FOR STORM PANELS.
  
 5)STRUCTURE IS LOCATED IN AN AO FLOOD
 ZONE. A FLOOD ELEVATION CERTIFICATE WILL
 BE REQUIRED.
  
 6) INDICATE THE MEAN ROOF HEIGHT OF THE
 STRUCTURE.
  
 7) PLEASE PROVIDE A DESIGN COMPLIANCE
 FORM COMPLETED BY THE DESIGNER OF RECORD
 FOR THE STRUCTURE.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202
  
  
 TRUSSES
 UNSAT
  
 1) THE BLOCK STAMP OF THE TRUSS ENGINEER
 IS REQUIRED ON THE TRUSS LAYOUT.
  
 2) THE TRUSS DETAIL DRAWINGS FOR GABLES,
 OVERHANG,ETC.ARE NOT SIGNED BY THE DATED
 BY THE TRUSS ENGINEER. THESE DRAWINGS
 ALSO REFERENCE INCORRECT DESIGN CRITERIA
 THE 97 STANDARD BUILDING CODE AS ADOPTED
 BY THE CITY OF WEST PALM BEACH REQUIRES
 THE DESIGN CRITERIA TO COMPLY WITH SECT.
 1606 (110 MPH WINDLOAD) OR ASCE 7-95
 (145 MPH WINDLOAD). PLEASE CORRECT.
  
 3) THE (2) TRUSS LAYOUTS SUBMITTED ARE
 NOT THE SAME. DIFFERENT TRUSS
 IDENTIFICATIONS ARE GIVEN FOR THE SAME
 TRUSSES. PLEASE CORRECT.
  
 4) THE MEAN ROOF HEIGHTS LISTED ON THE
 TRUSS DRAWINGS ARE NOT CONISTENT. THEY
 SHOULD ALL BE THE SAME AS THE MEAN ROOF
 HEIGHT OF THE STRUCTURE.
  
 5) THE DESIGN WINDLOAD ON THE TRUSS
 DRAWINGS LISTS 110 MPH SBCC 1997. PLEASE
 CORRECT TO SBC 1997 (STANDARD BUILDING
 CODE).

Review Stop Z ZONING
Rev No 1 Status P Date 2001-06-20 Cont ID  
Sent By sgraham Date 2001-06-20 Time 12:08 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***