Plan Review Details - Permit 01060716
Plan Review Stops For Permit 01060716
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-07-03 Cont ID  
Sent By dpalmer Date 2001-07-03 Time 17:58 Rev Time 0.00
Received By dpalmer Date 2001-07-03 Time 17:58 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2001-07-03 Cont ID  
Sent By mcarsill Date 2001-07-03 Time 14:53 Rev Time 0.00
Received By mcarsill Date 2001-07-03 Time 14:53 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2001-10-31 Cont ID  
Sent By pkrauss Date 2001-10-31 Time 16:45 Rev Time 0.30
Received By pkrauss Date 2001-10-31 Time 16:45 Sent To  
Notes
2001-10-31 00:00:00MECH REV 0106041

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-10-13 Cont ID  
Sent By pkrauss Date 2001-10-13 Time 06:48 Rev Time 0.05
Received By pkrauss Date   Time   Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-06-21 Cont ID  
Sent By hmoser Date 2001-06-21 Time 18:00 Rev Time 0.33
Received By hmoser Date 2001-06-21 Time 18:00 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2001-06-26 Cont ID  
Sent By kstevens Date 2001-06-26 Time 13:18 Rev Time 0.33
Received By kstevens Date 2001-06-26 Time 13:17 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 5 Status P Date 2001-11-26 Cont ID  
Sent By jgomez Date 2001-11-26 Time 11:47 Rev Time 0.25
Received By jgomez Date 2001-11-26 Time 11:47 Sent To  
Notes
2001-11-26 00:00:00TRUSS DRAWINGS REVIEW.

Review Stop R ROOF PLAN REVIEW
Rev No 4 Status F Date 2001-11-14 Cont ID  
Sent By jgomez Date 2001-11-14 Time 17:09 Rev Time 0.25
Received By jgomez Date 2001-11-14 Time 17:09 Sent To  
Notes
2001-11-14 00:00:00TRUSS DRAWINGS CHECKLIST:
 1-ENGINEERED TRUSSES ARE DESIGNED USING
 DIFFERENT MEAN ROOF HEIGHTS. THERE IS
 ONLY ONE MEAN ROOF HEIGHT FOR ENTIRE
 BUILDING. REVIEW ALL ENGINEERED
 TRUSSES AND REVISE AS REQUIRED.
 TABLE 1606.2A SBC 1997.
 2-SOME TRUSSES ARE DESIGNED USING WALL
 HEIGHT. THIS APPLIES TO A FLAT ROOF.
 USE MEAN ROOF HEIGHT FOR SLOPED ROOF.
 REVISED AS REQUIRED.
 3-GENERAL DETAILS:
 A)THERE ARE TWO DIFFERENT ENGINEERS.
 COMPLY WITH REQUIREMENTS OF CHAPTER
 471 FL. STATUTES WHEN CHANGING ENG'R.
 B)UPDATE GENERAL DETAILS DESIGN CRITERIA
 C)DETAILS AND SPECS ARE NOT LEGIBLE.
  
  
 NOTES:
 -THESE COMMENTS HAVE BEING ADDRESSED ON
 PREVIOUS REVIEWS.
 -DRAWINGS TO BE FILED UNDER PERMIT #
 01060716, 01060718, 01060721 AND
 01060723.

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status F Date 2001-11-14 Cont ID  
Sent By jgomez Date 2001-11-14 Time 11:06 Rev Time 0.25
Received By jgomez Date 2001-11-14 Time 11:06 Sent To  
Notes
2001-11-14 00:00:00ENERGY CALCULATIONS:
 CLARIFY WHY THE NUMBER OF BEDROOMS WERE
 WHITE OUT. THIS IS A COMPUTER PROGRAM
 AND ANY CHANGES SHALL BE DONE IN THE
 SYSTEM NOT BY HAND. OTHERWISE, IT WILL
 ALTER THE RESULTS. REVISE AS REQUIRED.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2001-08-03 Cont ID  
Sent By jgomez Date 2001-08-03 Time 17:58 Rev Time 0.25
Received By jgomez Date 2001-08-03 Time 17:58 Sent To  
Notes
2001-08-03 00:00:00CHECKLIST:
  
 1-NUMBER OF MULTIFAMILY UNITS IS NOT
 CORRECT. REVISE AS REQUIRED.
  
 2-AREA UNDER ATTIC IS INCORRECT. SEE
 SECTION 604.1.A.1 OF FLORIDA ENERGY
 EFFICIENCY CODE FOR BUILDING
 CONSTRUCTION. 1997 EDITION.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2001-07-05 Cont ID  
Sent By jgomez Date 2001-07-05 Time 18:46 Rev Time 1.00
Received By jgomez Date 2001-07-05 Time 18:46 Sent To  
Notes
2001-07-05 00:00:00APPROVED WITH PROVISO:
  
 1-FLOOD ZONE AO.
 NEED ELEVATION CERTIFICATE.
  
 2-REVISE ENERGY CALCULATIONS FOR
 MODEL D. FLOOR AREA DOESN'T MATCH
 ARCHITECT'S PLANS.
  
 3-PROVIDE PRODUCT APPROVAL FOR WINDOW
 MULLIONS.
  
 4-MISSING DRAWING SH-1.
  
 NOTE:
 THESE COMMENTS APPLY TO PERMIT NUMBERS:
 01060716, 01060718, 01060721 AND
 01060723.

Review Stop Z ZONING
Rev No 1 Status P Date 2001-06-19 Cont ID  
Sent By sgraham Date 2001-06-19 Time 16:34 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***