Plan Review Details - Permit 01060332
Plan Review Stops For Permit 01060332 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2001-06-22 |
|
|
Cont ID |
|
Sent By |
hpiskura |
Date |
2001-06-22 |
Time |
13:36 |
Rev Time |
0.00 |
Received By |
rturnque |
Date |
2001-07-12 |
Time |
10:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2001-07-09 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-07-09 |
Time |
13:49 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-07-09 |
Time |
13:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2001-06-13 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-06-13 |
Time |
22:15 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-06-13 |
Time |
22:15 |
Sent To |
|
|
Notes |
2001-06-13 00:00:00 | ***************** UNSAT ************ | | | | 1)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | ALL NEW EQUIPMENT BEING INSTALLED. | | MAINS/PANELS/BREAKERS MUST BE RATED FOR | | THE AVAILABLE FAULT CURRENT PER 110-9. | | PLEASE NOTE THAT AIC WAS SUBMITTED FOR | | PANELS BUT NOT FOR MAIN. | | | | 2) PLEASE CLARIFY EQUIPMENT GROUNDING | | METHOD BETWEEN FIRST MEANS OF | | DISCONNECTAND PANEL(S). EQUIPMENT | | GROUNDING CONDUCTORS ARE TO BE SIZED BY | | ART 250-122. | | | | 3)NOTE: PLEASE NOTE THAT NO LOAD | | CALCULATIONS WERE SUBMITTED ? PLEASE | | SEE ART;220 | | ALSO PLEASE SHOW ALL CONTINUOUS LOADS | | AT 125%.PER 215-3 AND 230-42 | | | | 4)NOTE: PLEASE SHOW ALL BRANCH CIRCUIT | | `#S ON PLANS AND CORRELATE WITH SUBMITT- | | -ED PANEL SCHEDULES. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
N |
Date |
2001-07-10 |
|
|
Cont ID |
|
Sent By |
lsmith |
Date |
2001-07-10 |
Time |
16:01 |
Rev Time |
0.00 |
Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2001-07-12 |
|
|
Cont ID |
|
Sent By |
rturnque |
Date |
2001-07-12 |
Time |
10:48 |
Rev Time |
0.15 |
Received By |
rturnque |
Date |
2001-07-12 |
Time |
10:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2001-06-12 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2001-06-12 |
Time |
09:21 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2001-06-12 |
Time |
09:21 |
Sent To |
|
|
Notes |
2001-06-12 00:00:00 | 1) INTERIOR FINISH IN EXITS SHALL BE | | CLASS A OR B. INTERIOR FINISH IN | | OTHER AREAS TO BE CLASS A,B,OR C. | | | | CAPTAIN MIKE CARSILLO | | 659-8096,EXT.8497 | | 835-2910 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2001-07-12 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2001-06-11 |
Time |
09:50 |
Rev Time |
0.50 |
Received By |
pkrauss |
Date |
2001-06-11 |
Time |
09:11 |
Sent To |
|
|
Notes |
2001-06-11 00:00:00 | *******************DENIED*************** | | | | PULL MECH FROM MAIN SET, CMI TO SUBMIT | | PLANS | | | | MECHANICAL PERMIT REQUIRED.PLEASE | | SUBMIT THE FOLLOWING INFORMATION FOR | | REVIEW. | | | | MANUFACTURER/ENGINEER DETAIL OF ROOF | | CURBS. | | | | LOCATION AND TERMINATION OF CONDENSATE. | | | | FAN SHUTDOWN BY DUCT SMOKE DETECTORS | | WITH NOTIFICATION TO ALARM/STROBE IN | | NORMALLY OCCUPIED AREAS. (1997 SMC 406.1 | | AND NFPA 90A 4-4.4.3, RESPECTIVELY) | | | | PLEASE PROVIDE OUTSIDE AIR CALCULATIONS | | AS PER ASHRAE 62-89. | | | | PLANS ARE NOT DATED OR SIGNED AND SEALED | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT | | PATTY KRAUSS AT 659-8096 EXT.8388. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2001-07-11 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2001-07-11 |
Time |
19:52 |
Rev Time |
0.50 |
Received By |
jleech |
Date |
2001-07-11 |
Time |
19:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2001-06-10 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
2001-06-10 |
Time |
12:55 |
Rev Time |
1.50 |
Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-06-10 00:00:00 | PLUMBING PLAN REVIEWPROVISO | | (1) SHT-2, WATER RISER, AIR CHAMBERS TO | | BE ACCESSIBLE,RECHARGEABLE. SPC 94 | | SEC 607.8.3 | | END OF COMMENTSPAUL SCHMITZ | | QUESTIONS561-659-8096X8233 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2001-07-10 |
|
|
Cont ID |
|
Sent By |
lsmith |
Date |
2001-07-10 |
Time |
16:01 |
Rev Time |
0.00 |
Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
|