Plan Review Details - Permit 01060054
Plan Review Stops For Permit 01060054
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-08-02 Cont ID  
Sent By dpalmer Date 2001-08-02 Time 11:11 Rev Time 0.00
Received By dpalmer Date 2001-08-02 Time 11:10 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2001-07-26 Cont ID  
Sent By mcarsill Date 2001-07-26 Time 11:00 Rev Time 0.00
Received By mcarsill Date 2001-07-26 Time 11:00 Sent To  
Notes
2001-07-26 00:00:001) BUILDING ADDRESS REQUIRED PER CITY
 CODE 3343-00.
 2) WET FIRE HYDRANTS ARE REQUIRED PRIOR
 TO,DURING AND AFTER CONSTRUCTION.
 3) ELECTRIC POWERED SMOKE DETECTORS
 REQUIRED. WHEN ACTIVATED THESE DETECTORS
 ARE TO BE AUDIBLE IN THE SLEEPING ROOMS
 OF THAT UNIT.
 4) PORTABLE FIRE EXTINGUISHERS WITH
 CURRENT SERVICE TAGS ARE REQUIRED.
  
 CAPTAIN MIKE CARSILLO
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-08-04 Cont ID  
Sent By hmoser Date 2001-08-04 Time 07:06 Rev Time 0.33
Received By hmoser Date 2001-08-04 Time 07:06 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2001-06-14 Cont ID  
Sent By pkrauss Date 2001-06-14 Time 10:05 Rev Time 0.25
Received By pkrauss Date 2001-06-14 Time 10:05 Sent To  
Notes
2001-06-14 00:00:00*******************DENIED***************
  
  
 ARCHITECT FLOOR PLANS DO NOT MATCH
 MECHANICAL FLOOR PLANS.
  
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT
 HAROLD MOSER AT 659-8096 EXT. 8390
  
 OR
  
 PATTY KRAUSS 659-8096 EXT.8388.

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-08-03 Cont ID  
Sent By kstevens Date 2001-08-03 Time 13:25 Rev Time 1.00
Received By kstevens Date 2001-08-03 Time 13:25 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-06-08 Cont ID  
Sent By kstevens Date 2001-06-08 Time 10:55 Rev Time 0.50
Received By kstevens Date 2001-06-08 Time 10:55 Sent To  
Notes
2001-06-08 00:00:00REVIEW NOTES:FAILED
  
 1) PAGE 1A & PAGE 2 GENERAL NOTES #11
 CHANGE TO READ FHA 1998 DESIGN MANUAL.
  
 2) MODEL 1527 (L) & (R), M/B SHOWS 1'-7"
 TO CENTER OF W/C, AND IT SHOULD BE 1'-6"
 ALSO SHOW CLEAR FLOOR SPACE FOR LAV.
 PAGES 1A & 1B.
  
 3) IN BATH #2 SHOW CLEAR FLOOR SPACE FOR
 W/C AND LAV. PAGES 1A & 1B.
  
 4) MODEL 1409 (L) & (R), M/B SHOWS 1'-7"
 TO CENTER OF W/C, AND IT SHOULD BE 1'-6"
 ALSO SHOW CLEAR FLOOR SPACE FOR LAV.
 PAGES 1A & 1B.
  
 5) BATH #2 SHOWS 2'-8" OPENING FOR W/C.
 2'-9" MINIMUM SPACE REQUIRED FOR W/C.
 ALSO SHOW CLEAR FLOOR SPACE FOR W/C AND
 LAV. PAGES 1A & 1B.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT. 8377

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2001-08-07 Cont ID  
Sent By jgomez Date 2001-07-23 Time 13:51 Rev Time 1.00
Received By aneil Date 2001-07-23 Time 13:51 Sent To  
Notes
2001-07-23 00:00:00CHECKLIST:
 SEE COMMENTS ON PERMIT #01060039.

Review Stop Z ZONING
Rev No 1 Status P Date 2001-06-05 Cont ID  
Sent By sgraham Date 2001-06-05 Time 14:23 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***