Plan Review Details - Permit 01060039
Plan Review Stops For Permit 01060039
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2002-01-07 Cont ID  
Sent By btrobaug Date 2002-01-07 Time 15:19 Rev Time 0.50
Received By btrobaug Date 2002-01-07 Time 15:18 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-08-02 Cont ID  
Sent By dpalmer Date 2001-08-02 Time 11:09 Rev Time 0.00
Received By dpalmer Date 2001-08-02 Time 11:09 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2001-07-26 Cont ID  
Sent By mcarsill Date 2001-07-26 Time 10:18 Rev Time 0.00
Received By mcarsill Date 2001-07-26 Time 10:18 Sent To  
Notes
2001-07-26 00:00:001) BUILDING ADDRESS REQUIRED PER CITY
 CODE 3343-00.
 2) WET FIRE HYDRANTS ARE REQUIRED PRIOR
 TO, DURING AND AFTER CONSTRUCTION.
 3) ELECTRIC POWERED SMOKE DETECTORS ARE
 REQUIRED. WHEN ACTIVATED, THEY ARE TO
 BE AUDIBLE IN THE SLEEPING ROOMS OF THAT
 UNIT.
 4) PORTABLE FIRE EXTINGUISHERS ARE
 REQUIRED WITH CURRENT SERVICE TAGS.
  
 CAPTAIN MIKE CARSILLO
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-08-04 Cont ID  
Sent By hmoser Date 2001-08-04 Time 06:59 Rev Time 0.33
Received By hmoser Date 2001-08-04 Time 06:59 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2001-06-14 Cont ID  
Sent By pkrauss Date 2001-06-14 Time 10:25 Rev Time 0.25
Received By hmoser Date 2001-06-14 Time 10:25 Sent To  
Notes
2001-06-14 00:00:00********************DENIED**************
  
  
 ARCHITECT FLOOR PLANS DO NOT MATCH
 MECHANICAL FLOOR PLANS.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT
 HAROLD MOSER AT 659-8096 EXT.8390
  
 OR
  
 PATTY KRAUSS AT 659-8096 EXT.8388.

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-08-03 Cont ID  
Sent By kstevens Date 2001-08-03 Time 13:20 Rev Time 1.00
Received By kstevens Date 2001-08-03 Time 13:20 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-06-08 Cont ID  
Sent By kstevens Date 2001-06-08 Time 10:15 Rev Time 0.33
Received By kstevens Date 2001-06-08 Time 10:15 Sent To  
Notes
2001-06-08 00:00:00REVIEW NOTES:FAILED
  
 1) PAGE 1A & PAGE 2 GENERAL NOTES #11
 CHANGE TO READ FHA 1998 DESIGN MANUAL.
  
 2) MODEL 1527 (L) & (R), M/B SHOWS 1'-7"
 TO CENTER OF W/C, AND IT SHOULD BE 1'-6"
 ALSO SHOW CLEAR FLOOR SPACE FOR LAV.
 REF. PAGES 1A AND 1B.
  
 3) IN BATH 2 SHOW CLEAR FLOOR SPACE FOR
 W/C AND LAV. PAGES 1A & 1B
  
 4) MODEL 1409 (L) & (R), M/B SHOWS 1'-7"
 TO CENTER OF W/C, AND IT SHOULD BE 1'-6"
 ALSO SHOW CLEAR FLOOR SPACE FOR LAV.
 PAGES 1A & 1B
  
 5) BATH #2 SHOWS 2'-8" OPENING FOR W/C.
 2'-9" MINIMUM SPACE REQUIRED FOR W/C.
 ALSO SHOW CLEAR FLOOR SPACE FOR W/C AND
 LAV. PAGES 1A & 1B
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT. 8377

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status F Date 2001-09-17 Cont ID  
Sent By jgomez Date 2001-09-17 Time 18:25 Rev Time 0.33
Received By jgomez Date 2001-09-17 Time 18:25 Sent To  
Notes
2001-09-17 00:00:00TRUSS DRAWINGS CHECKLIST:
  
 1-TRUSS LAYOUT TO HAVE THE ENGINEER'S
 INFORMATION AS REQUIRED BY CHAPTER
 471 OF FLORIDA STATUTES WHEN SUBMITT'G
 INFORMATION FOR PUBLIC RECORDS.
  
 2-PROFESSIONAL DESIGNER OF RECORD TO
 REVIEW ALL TRUSS DRAWINGS PRIOR TO
 SUBMITTAL TO THIS OFFICE.
  
 3-CLARIFY WHY THERE ARE TWO DIFFERENT
 ENGINEERS SIGNING AND SEALING THE
 ENGINEERED TRUSS DRAWINGS. NAMES ARE
 SIMILAR BUT THEY HAVE DIFFERENT
 LICENSE NUMBER.
  
 4-PROVIDE TWO PACKAGES OF TRUSS DWGS.
 ONLY ONE SET WAS SUBMITTED.
  
  
  
  
 NOTES:
 -DRAWINGS TO BE FILED UNDER PERMIT #
 01060039.
 -THESE COMMENTS APPLY TO PERMITS #S:
 01060039, 01060052, 01060054 AND
 01060055.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2001-08-02 Cont ID  
Sent By jgomez Date 2001-08-02 Time 15:19 Rev Time 1.00
Received By jgomez Date 2001-08-02 Time 15:19 Sent To  
Notes
2001-08-02 00:00:00APPROVED WITH PROVISO:
  
 1-FLOOD ZONE AO.WILL NEED ELEVATION
 CETIFICATE.
 2-PROVIDE COMPLETE INFORMATION FOR STORM
 PANELS UNDER A SEPARATE PERMIT.
 3-REVISE EITHER THE ENERGY CALCULATIONS
 OR ARCHITECTURAL PLANS TO MATCH THE
 WATER HEATER CAPACITY. (40 GALS OR
 50 GALS).
 4-PROVIDE PRODUCT APPROVAL FOR TWO HOUR
 FIRE RATED CONCRETE BLOCK.
  
  
  
  
  
 NOTES:
 -DRAWINGS TO BE FILED UNDER PERMIT #:
 01060039.
 -THESE COMMENTS APPLY TO PERMITS #S:
 01060039, 01060052, 01060054 AND
 01060055.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2001-07-23 Cont ID  
Sent By jgomez Date 2001-07-23 Time 13:35 Rev Time 1.00
Received By jgomez Date 2001-07-23 Time 13:35 Sent To  
Notes
2001-07-23 00:00:00CHECKLIST:
 1-FAILED BY PLUMBING AND MECHANICAL
 PLAN REVIEWERS. SEE THEIR COMMENTS.
 2-FILE NOTICE OF COMMENCEMENT.
 3-PROVIDE PRODUCT APPROVAL FOR:
 -SINGLE HUNG WINDOWS.
 -WINDOW MULLIONS.
 -2 HOUR FIRE RATED CONCRETE BLOCK.
 4-PROVIDE COMPLETE INFORMATION FOR STORM
 PANELS OR APPLY FOR A SEPARATE PERMIT.
 5-CLEARLY INDICATE OPTIONS THAT ARE
 GOING TO BE BUILT. SEE DRAWING #2 AND
 CROSS OUT OPTIONS THAT DON'T APPLY.
  
  
  
 NOTES:
 -DRAWINGS TO BE FILED UNDER PERMIT #
 01060039.
 -THESE COMMENTS APPLY TO PERMIT #S:
 01060039, 01060052, 01060054 AND
 01060055.

Review Stop Z ZONING
Rev No 1 Status P Date 2001-06-05 Cont ID  
Sent By sgraham Date 2001-06-05 Time 14:23 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***