Plan Review Details - Permit 01051002
Plan Review Stops For Permit 01051002
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2001-08-06 Cont ID  
Sent By jwitmer Date 2001-08-06 Time 17:21 Rev Time 0.75
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2001-07-17 Cont ID  
Sent By jwitmer Date 2001-07-17 Time 18:32 Rev Time 0.75
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2001-06-11 Cont ID  
Sent By jwitmer Date 2001-06-11 Time 11:21 Rev Time 3.50
Received By jwitmer Date   Time   Sent To  
Notes
2001-06-11 00:00:00BUILDING PLAN REVIEW
 PERMIT # 01051002
 222 LAKEVIEW SUITE # 1600
 CATALFUMO CONT.
 P 694-3000
  
 1)- TITLE SHEET CODE COMPLIANCE & EGRESS
 NOTES: FINISH MATERIALS COMPLY WITH
 FLAME SPREAD RATING AS REQUIRED BYTHE
 STANDARD BUILDING CODE, 1997 EDITION.
  
 2)- NOTE # 1 REFERS BACK TO SBC CHAPTER
 23 FOR MINIMUM ALLOWANCE 5 LBS./ SQ FT
 LATERAL LOAD REQUIREMENTS, THERE IS NO
 2305.9 AS STATED ON PLANS.
  
 3)- HANDICAPPED BARRIERS PER PLAN
 SBC SECTION 4.1.6/4.1.9 SHOULD READ 1997
 FLORIDA ACCESSIBILITY CODE FOR BUILDING
 CONSTRUCTION.
  
 4)- SHEET 01 LEGEND: PARTITION TYPE 1
 LIST UL LISTING OR GYPSUM ASSOC # FOR
 ASSEMBLY ALSO INDICATE STANDARD BUILDING
 CODE 704.2 INTERIOR WALLS & PARTITION
 FIRE SEPERATION REQUIREMENTS.
  
 5)- SBC 704.2.1.4 CORRIDOR PARTITIONS
 SHALL BE EFFECTIVELY & PERMANETLY WITH
 SIGN OR STENCILING IN A MANNER ABOVE ANY
 DECORATIVE CEILING OR CONSEALED SPACE
 "FIRE & SMOKE BARRIER PROTECT ALL OPEN-I
 NGS".
  
 6)- SBC 609.2.1. TYPE I & TYPE II BUILD-
 INGS REQUIRE ALL WOOD IN PARTITIONS,
 FIRE TREATED WOOD.
  
 7)- SHEET 49.01. MISSING IS THE MINIMUM
 INTERIOR FINISH CLASSIFICATION SCHEDULE
 SBC TABLE 803.3.
  
 8)- SBC 412.9 MANUAL FIRE ALARM BOXES
 SHALL BE PROVIDED.
  
 9)- FIRE SPRINKLERS SBC 412.10 HI-RISE
 TYPE BUILDINGS REQUIRE FIRE SPRINKLERS.
  
 BUILDING OLAN REVIEW
 JIM WITMER
 (561) 659-8096 EX 8412

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2001-10-01 Cont ID  
Sent By dpalmer Date 2001-10-01 Time 17:15 Rev Time 0.00
Received By dpalmer Date 2001-10-01 Time 17:15 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2001-08-08 Cont ID  
Sent By dpalmer Date 2001-08-08 Time 21:28 Rev Time 0.00
Received By dpalmer Date 2001-08-08 Time 21:28 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-06-07 Cont ID  
Sent By dpalmer Date 2001-06-07 Time 19:45 Rev Time 0.00
Received By dpalmer Date 2001-06-07 Time 19:45 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2001-09-27 Cont ID  
Sent By mcarsill Date 2001-09-27 Time 15:03 Rev Time 0.00
Received By mcarsill Date 2001-09-27 Time 15:03 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2001-07-25 Cont ID  
Sent By mcarsill Date 2001-07-25 Time 13:19 Rev Time 0.00
Received By mcarsill Date 2001-07-25 Time 13:19 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2001-07-12 Cont ID  
Sent By rturnque Date 2001-07-12 Time 15:30 Rev Time 0.25
Received By rturnque Date   Time   Sent To  
Notes
2001-07-12 00:00:00PROVIDE FIRE SPRINKLER DRAWINGS
 PROVIDE FIRE ALARM DRAWINGS.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2001-05-23 Cont ID  
Sent By mcarsill Date 2001-05-23 Time 09:16 Rev Time 0.00
Received By mcarsill Date 2001-05-23 Time 09:16 Sent To  
Notes
2001-05-23 00:00:001) NO FIRE SPRINKLER DRAWINGS PROVIDED
 WITH PLANS.
 2) NO FIRE ALARM EQUIPMENT SHOWN ON
 PLANS.
 3) PLEASE PROVIDE PRODUCT APPROVALS FOR
 FIRE PLUS ONE HOUR FIRE RATED CLEAR
 GLASS PANELS. PLEASE PROVIDE PRODUCT
 APPROVAL FOR C LABEL FIREGUARD PLUS
 FIRE DOOR.
 4) NO INTERIOR FINISH INFORMATION
 PROVIDED WITH PLANS.
  
 CAPTAIN MIKE CARSILLO
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-06-29 Cont ID  
Sent By pkrauss Date 2001-06-29 Time 15:51 Rev Time 0.25
Received By pkrauss Date 2001-06-29 Time 15:51 Sent To  
Notes
2001-06-29 00:00:00DUCT SMOKE DETECTORS TO ALARM/STROBE
 ARE INDICATED ON DRAWING E-3, AS PER
 CONVERSATION WITH BOB DAVIS ELEC ENG.
 (877) 967-7980.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2001-06-08 Cont ID  
Sent By pkrauss Date 2001-06-08 Time 15:11 Rev Time 0.40
Received By pkrauss Date 2001-06-08 Time 14:47 Sent To  
Notes
2001-06-08 00:00:00******************DENIED****************
  
  
 PLEASE INDICATE LOCATIONS OF DUCT SMOKE
 DETECTORS ON PLAN.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT
 PATTY KRAUSS AT 659-8096 EXT.8388.

Review Stop P PLUMBING
Rev No 3 Status P Date 2001-10-05 Cont ID  
Sent By kstevens Date 2001-10-05 Time 11:03 Rev Time 0.33
Received By kstevens Date 2001-10-05 Time 11:02 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-07-18 Cont ID  
Sent By jleech Date 2001-07-18 Time 07:25 Rev Time 0.75
Received By jleech Date 2001-07-18 Time 07:25 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-06-02 Cont ID  
Sent By pschmitz Date 2001-06-02 Time 13:04 Rev Time 1.00
Received By pschmitz Date   Time   Sent To  
Notes
2001-06-02 00:00:00PLUMBING PLAN REVIEWDENIED
 (1) SHT 46-02 INTERIOR ELEVATIONS,
 BREAK RM SINK,TO COMPLY W/FACBC 97
 SEC 4.24.2, HGTH 34", 4.24.3,KNEE CLEAR-
 ANCE,AT LEAST 27"HIGH,30"WIDE, 4.24.5
 CLEAR FLR SPACE 30"X 48" AND 19"UNDER
 THE SINK.
 END OF COMMENTSPAULSCHMITZ
 QUESTIONS561-659-8096 X 8233