Plan Review Details - Permit 01050945
Plan Review Stops For Permit 01050945
Review Stop P PLUMBING
Rev No 2 Status P Date 2001-05-30 Cont ID  
Sent By kstevens Date 2001-05-30 Time 20:00 Rev Time 0.33
Received By kstevens Date 2001-05-30 Time 20:00 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-05-19 Cont ID  
Sent By kstevens Date 2001-05-19 Time 12:43 Rev Time 0.75
Received By kstevens Date 2001-05-19 Time 12:43 Sent To  
Notes
2001-05-19 00:00:00REVIEW NOTES...FAILED..
  
 1) CHART FOR CSST PIPE NOT ACCEPTABLE.
 CHART 305.4F OF SGC-97 MUST BE USED. AND
 80' OF 1" CSST ONLY ALLOWS FOR 132,000
 BTU'S.
  
 2) 1/2" GALV. DROP TO RANGE TO BE SIZED
 AT 3/4". 1/2" ONLY ALLOWS FOR 57,000 BTU
 AT 80'.
  
 RESIZE AND RESUBMIT USING APPROIATE
 CHART AND PIPE.
  
 REVIEW BY KEN STEVENS (561) 659-8096
 EXT. 8377