Plan Review Details - Permit 01050211
Plan Review Stops For Permit 01050211 |
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2001-05-14 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-05-14 |
Time |
18:41 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-05-14 |
Time |
18:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2001-05-31 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2001-05-31 |
Time |
09:08 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2001-05-31 |
Time |
09:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2001-10-31 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2001-10-31 |
Time |
14:48 |
Rev Time |
0.30 |
Received By |
pkrauss |
Date |
2001-10-31 |
Time |
14:48 |
Sent To |
|
|
Notes |
2001-10-31 00:00:00 | MECH REV PERMIT 01050269 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2001-09-29 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2001-09-29 |
Time |
11:12 |
Rev Time |
0.10 |
Received By |
pkrauss |
Date |
2001-09-29 |
Time |
11:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2001-05-12 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2001-05-12 |
Time |
13:58 |
Rev Time |
0.33 |
Received By |
hmoser |
Date |
2001-05-12 |
Time |
13:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2001-05-10 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2001-05-10 |
Time |
19:21 |
Rev Time |
0.25 |
Received By |
kstevens |
Date |
2001-05-10 |
Time |
19:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
F |
Date |
2001-08-03 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2001-08-03 |
Time |
18:30 |
Rev Time |
0.25 |
Received By |
jgomez |
Date |
2001-08-03 |
Time |
18:30 |
Sent To |
|
|
Notes |
2001-08-03 00:00:00 | CHECKLIST: | | | | 1-PROVIDE CURRENT DADE COUNTY PRODUCT | | APPROVAL FOR WINDOW MULLIONS. | | INFORMATION SUBMITTED IS NOT AN | | OFFICIAL PRODUCT APPROVAL. | | | | 2-PRODUCT APPROVAL FOR PRECAST LINTELS | | WAS APPROVED. |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
P |
Date |
2001-06-04 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2001-06-04 |
Time |
15:00 |
Rev Time |
1.00 |
Received By |
jgomez |
Date |
2001-06-04 |
Time |
15:00 |
Sent To |
|
|
Notes |
2001-06-04 00:00:00 | APPROVED WITH PROVISO: | | 1-FLOOD ZONE AO, PROVIDE ELEVATION | | CERTIFICATE. | | 2-TOWNHOUSES ARE SEPARATED BY TWO HOUR | | FIRE RATED WALL. MODEL C HAS GLASS | | BLOCK AT ZERO LOT LINE. PROVIDE TWO | | HOUR FIRE RATED GLASS BLOCK OR CLOSE | | OPENING. SEC 704.4.2 SBC 1997. | | 3-PROVIDE PRODUCT APPROVAL FOR: | | -TWO HR FIRE RATED GLASS BLOCK. | | -PRECAST LINTEL EXPIRED 5-21-01. | | -WINDOW MULLIONS | | 4-REVISE NOTE #2 ON SHEET BP-1: MAX. | | CHANGE IN LEVEL IS 1/4" OR 1/2" MAX. | | IF BEVELED. FAIR HOUSING ACT. PAGE 4.4 | | | | | | | | | | NOTE: THESE COMMENTS APPLY TO PERMIT | | 01050211, 01050212, 01050208, | | 01050209 AND 01050210 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2001-05-10 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2001-05-10 |
Time |
13:11 |
Rev Time |
0.25 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
|