Plan Review Stops For Permit 01050082 |
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2001-11-06 |
Time |
10:50 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-11-06 00:00:00 | OK PER D. PALMER 11-6-01 RM |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2001-10-29 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-10-29 |
Time |
21:29 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-10-29 |
Time |
21:29 |
Sent To |
|
|
Notes |
2001-10-29 00:00:00 | ******************* UNSAT ************** | | | | 1)NOTE: PLEASE NOTE THAT ONLY ONE | | COPY WAS SUBMITTED. PLEASE SUBMIT TWO. | | | | 2)NOTE: PLEASE NOTE OUTLETS SHOWN FOR | | KITCHEN COUNTERSPACE NEED TO BE SHOWN | | AS GFI/GFI PROTECTED. 210-8-A-6. | | | | PLEASE SUBMIT THE ABOVE FOR REVIEW. | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2001-05-23 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-05-23 |
Time |
07:27 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-05-23 |
Time |
07:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2001-10-30 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2001-10-30 |
Time |
14:28 |
Rev Time |
0.35 |
Received By |
pkrauss |
Date |
2001-10-30 |
Time |
14:08 |
Sent To |
|
|
Notes |
2001-10-30 00:00:00 | | | PLANS ARE NOT SEALED BY ENGINEER OF | | RECORD. | | | | DRYER VENT LOCATION SIZE OR OF VENT NOT | | INDICATED ON PLAN. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2001-06-11 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2001-06-11 |
Time |
14:27 |
Rev Time |
0.35 |
Received By |
pkrauss |
Date |
2001-06-11 |
Time |
14:11 |
Sent To |
|
|
Notes |
2001-06-11 00:00:00 | RESUBMITAL-CHANGED 1.5 TON TO 3 TON | | UNIT.ALSO ADDED CFM THAT | | WAS MISSING FROM DROP IN | | BEDROOM 2. | | | | APPROVED 6/11/01PHK. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2001-05-19 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2001-05-19 |
Time |
14:04 |
Rev Time |
0.50 |
Received By |
hmoser |
Date |
2001-05-19 |
Time |
14:05 |
Sent To |
|
|
Notes |
2001-05-19 00:00:00 | A/C #2 WRONG SIZE 1225CFM 1.50 TON A/C | | DROP IN BEDROOM #2 NO GRILL SIZE OR CFM |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2001-05-07 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2001-05-07 |
Time |
11:06 |
Rev Time |
0.25 |
Received By |
kstevens |
Date |
2001-05-07 |
Time |
11:06 |
Sent To |
|
|
Notes |
2001-05-07 00:00:00 | REVIEW NOTES. PASSED | | | | *****PROVISO***** | | | | SANITARY RISER DIAGRAM DOES NOT COMPLY | | WITH CODE SPC-94 913.2. SUBMIT SANITARY | | RISER DIAGRAM WITH CORRECTONS. | | | | REVIEW BY KEN STEVENS (561) 659-8096 | | EXT. 8377 |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
4 |
Status |
P |
Date |
2001-11-06 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2001-11-06 |
Time |
10:48 |
Rev Time |
1.00 |
Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-11-06 00:00:00 | REVISION OK 11-6-01 RM |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
3 |
Status |
F |
Date |
2001-11-02 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2001-11-02 |
Time |
16:48 |
Rev Time |
1.00 |
Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-11-02 00:00:00 | REVISION DENIED | | - REVISED SHEETS A-2 ARE REQUIRED TO BE | | SIGNED, SEALED AND DATED BY THE DESIGNER | | OF RECORD (ENGINEER). |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
P |
Date |
2001-06-13 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2001-06-13 |
Time |
12:33 |
Rev Time |
3.00 |
Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-06-13 00:00:00 | ************BUILDING PROVISO************ | | | | 1)PROVIDE (2) CURRENT AND COMPLETE | | COPIES OF SBCCI OR METRO-DADE PRODUCT | | APPROVALS FOR: | | - GLASS BLOCK;(THE INFORMATION SUBMITTED | | IS NOT ACCEPTABLE.) | | | | 2) PROVIDE KEY PLAN AND INSTALLATION | | SCHEDULE FOR STORM PANELS PRIOR TO | | INSTALLATION. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)659-8096 EXT.8202 |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2001-06-06 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2001-06-06 |
Time |
13:28 |
Rev Time |
4.00 |
Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-06-06 00:00:00 | *************BUILDING UNSAT************* | | | | 1)PROVIDE (2) CURRENT AND COMPLETE | | COPIES OF SBCCI OR METRO-DADE PRODUCT | | APPROVALS FOR: | | - EXTERIOR WINDOWS | | - EXTERIOR DOORS | | - GARAGE DOOR | | - STORM PANELS | | - GLASS BLOCK | | | | 2) PROVIDE (2) PRODUCT APPROVALS, KEY | | PLANS AND INSTALLATION SCHEDULES | | INDICATING THE SPECIFIC TYPES OF ANCHORS | | TO BE USED FOR STORM PANELS. | | | | 3) PROVIDE SOIL TEST PER SEC. 1804.2.2 | | OF CITY AMENDMENTS TO 1997 SBC. | | | | 4) PROVIDE ENERGY CALCULATIONS AND | | MANUAL "J" CALCULATIONS PER 97 FLORIDA | | ENERGY CODE FOR BUILDING CONSTRUCTION. | | | | 5) WALL SECTIONS 4&5 ON A-6 INDICATE | | R-13 INSULATION AND THE FLOOR PLAN ON | | A-2 INDICATES R-11 INSULATION PLEASE | | CORRECT. | | | | 6) THE SCALES GIVEN FOR THE ELEVATIONS | | ON A-3 ARE INCORRECTLY LISTED AS 1/8" = | | 1'-0". PLEASE CORRECT. | | | | 7) PROVIDE CONSTRUCTION DETAILS FOR ARCH | | OPENINGS IN EXTERIOR WALLS. | | | | 8) PROVIDE DESIGN COMPLIANCE FORM TO | | INDICATE THE DESIGN PARAMETERS AND | | ASSUMPTIONS USED FOR THIS STRUCTURE. | | | | 9) SPACING OF VERTICLE WALL REINFORCE- | | MENT DOES NOT COMPLY WITH SSTD 10-97. | | PEASE REVIEW AND CORRECT, IF USING THE | | PRESCRIPTIVE METHOD OF DESIGN COMPLIANCE | | | | 10) PROVIDE DESIGN PARAMETERS AND | | ASSUMPTIONS USED TO DETERMINE FORCES AND | | REACTIONS APPLIED TO ROOF TRUSSES AND | | GIRDERS. | | | | 11) INDICATE THE TRUSS CONNECTORS THAT | | WILL BE USED ON THE TRUSSES THAT ARE NOT | | SPECIFICALLY INDICATED ON PLANS. | | | | 12) INDICATE MEAN ROOF HEIGHT ON PLANS. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)659-8096 EXT.8202 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2001-05-03 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2001-05-03 |
Time |
10:52 |
Rev Time |
0.25 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|