Plan Review Details - Permit 01030213
Plan Review Stops For Permit 01030213
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2001-05-26 Cont ID  
Sent By jwitmer Date 2001-05-26 Time 10:29 Rev Time 0.50
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2001-04-02 Cont ID  
Sent By jwitmer Date 2001-04-02 Time 15:14 Rev Time 1.25
Received By jwitmer Date   Time   Sent To  
Notes
2001-04-02 00:00:00BUILDING PLAN REVIEW
 JIM WITMER
 (561) 659-8096 EX 8412
  
 1)- TABLE 600 EXT. BEARING WALL 3'/10'
 ALLOWABLE OPENINGS IN WALL 10%. NEED TO
 REDUCE OPENING BY 63.82 SQ. FT.
  
 13.8750'X 65'= 901.88 SQ. FT
 901.88 S.F. X 10%= 90.18 SQ. FT.
  
 OPENING:
 14' X 11"= 154'
 154'- 90.18'= 63.82'
  
 BUILDING PLAN REVIEW
 JIM WITMER
 (561) 659-8096 EX 8412

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-03-29 Cont ID  
Sent By dpalmer Date 2001-03-29 Time 21:54 Rev Time 0.00
Received By dpalmer Date 2001-03-29 Time 21:54 Sent To  
Notes
2001-03-29 00:00:00************NOTES **********
  
 1)NOTE: NOTES ON PLANS TO RECEIVED FPL
 REPORT OF LOAD FOR SERVICE.
 REPORT TO BE IN FOR PLAN REVIEW AND ON
 SIET BEFORE ROUGH ELECTRICAL INSPECTION
 AND SERVICE CHANGE.,
 NOTES FOR BLDG. STEEL AND NO EQUIPMENT
 GROUND FROM METER TO MAIN.

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2001-06-15 Cont ID  
Sent By drunnels Date 2001-06-15 Time 15:16 Rev Time 0.00
Received By drunnels Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2001-03-28 Cont ID  
Sent By mcarsill Date 2001-03-28 Time 12:32 Rev Time 0.00
Received By mcarsill Date 2001-03-28 Time 12:32 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-08-27 Cont ID  
Sent By pkrauss Date 2001-08-27 Time 10:24 Rev Time 0.40
Received By pkrauss Date 2001-08-27 Time 10:23 Sent To  
Notes
2001-08-27 00:00:00MECHANICAL PLANS WERE SUBMITTED ON
 ORIGINAL SUBMITTAL (PLAN SHEET P-4),
 APPROVED AS PER P. KRAUSS.ONE EXHAUST
 FAN FOR WITH TWO DROPS IN RESTROOMS.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2001-03-23 Cont ID  
Sent By pkrauss Date 2001-03-23 Time 14:34 Rev Time 0.45
Received By pkrauss Date 2001-03-23 Time 13:57 Sent To  
Notes
2001-03-23 00:00:00INSUFFICIENT INFORMATION FOR MECHANICAL
 REVIEW.
  
 SEPERATE PERMIT REQUIRED FOR NEW
 WALK-IN BEER COOLER.PLEASE PROVIDE
 PLANS WITH PERMIT APPLICATION.
  
 SEPERATE PERMIT REQUIRED IF ANY WORK OR
 CHANGES TO HOOD/FIRE SUPRESSION.PLEASE
 PROVIDE PLANS WITH PERMIT APPLICATION.
  
 DRAWING A-1 INDICATES REFRIGERANT AND
 CONDENSATE LINES TO BE RELOCATED,
 MECHANICAL PERMIT REQUIRED PRIOR TO ANY
 WORK OR DEMOLITION BEING DONE.PLEASE
 PROVIDE PLANS WITH PERMIT APPLICATION.

Review Stop P PLUMBING
Rev No 3 Status P Date 2001-08-10 Cont ID  
Sent By kstevens Date 2001-08-10 Time 18:56 Rev Time 0.75
Received By kstevens Date 2001-08-10 Time 18:56 Sent To  
Notes
2001-08-10 00:00:00PROVISO
  
 TWO WAY CLEAN-OUTS ON INLET AND DRAIN
 SIDES OF EACH GREAS TRAPS. C/O'S EVERY
 80 FEET ON 4" SEWER LINE.
  
 REVIEW KEN STEVENS

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-05-27 Cont ID  
Sent By pschmitz Date 2001-05-27 Time 19:08 Rev Time 2.00
Received By pschmitz Date   Time   Sent To  
Notes
2001-05-27 00:00:00PLUMBING PLAN REVIEW" PROVISO"
 SEE PLBG PLBG SHTS,
 SEPERATE PREMIT FOR GREASE TRAP TO BE
 SIZED BY WPB REGIONAL SEWER TREATMENT
 PLANT RODNEY COMPO 561-837-4074
 SEPERATE PERMIT FOR GAS REQUIRED, SEE
 PROVISO ON SHT P-6
 END OF COMMENTSPAUL SCHMITZ
 QUESTIONS 561-659-8096 X 8233

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-04-11 Cont ID  
Sent By kstevens Date 2001-04-11 Time 16:34 Rev Time 5.00
Received By pschmitz Date 2001-04-11 Time 16:34 Sent To  
Notes
2001-04-11 00:00:00REVIEW NOTES:
 PLUMBING PLAN REVIEW DENIED.
 REFERENCES STD PLBG CODE-94 FACBC-97
 (1) CONTACT DEPT. OF BUSINESS
 REGULATION, HOTEL &RESTURANT DIVISION
 PRIOR TO PLUMBING PLAN REVIEW FOR THEIR
 COMMENTS & REVIEW. (954) 958-5520
  
 (2) PAGE A-4 ELEVATIONS #6 & #7 URNAL
 LIP TO 17" AFF. FACBC-97 4.18.2
  
 (3) PAGE P-1 PLMG NOTE # 5
 AIR CHAMBERS TO BE ACCESSABLE AND
 RECHARGABLE. SPC-94 607.8.3
  
 (4) NOTE; GREASE TRAP TO BE SIZED BY
 RODNEY COMPO OF THE WPB UTILITY DEPT.
 (561) 837-4074
  
 (5) TWO INCH VENT FORM GREASE TRAP
 NOT REQUIRED. 3" VENT WILL BE
 EXCEPTABLE.
  
 (6) PAGE P-3 DISHWASHER SHALL DISCHARGE
 INTO SANITARY NOT GREASE.
  
 (7) PAGE P-3 SANITARY AND GREASE LINES
 SHALL HAVE 2-WAY CLEAN-OUTS AT SEWER
 CONNECTIONS WITH-IN 3' OF BLDG.
  
 (8) PAGE P-3NO RECEPTICAL FOR ICE
 MACHINE TO DRAIN INTO.
  
 (9) PAGES P-4 & P-5 SHOWES 140 DEGREE
 HAT WATER TO SS-1 HAND SINK. THIS IS
 NOT ACCEPTABLE.
  
 (10) PAGE P-5 WASTE & VENT PIPING
 DIAGRAM SHOWS HORIZONTAL DRY VENT.
 HORIZONTAL DRY VENTS NOT ALLOWED
 SPC-94 914.2
  
 (11) PAGE P-6 WATER HEATER DETAIL:
 RELIEF DRAIN LINE TO DISCHARGE OUTSIDE
 OF BLDG. IN AN OBSERVABLE LOCATON.
 SPC-94 507.8.4
  
 (12) WOMEN'S AND MEN'S HDCP STALLS DOOR
 SWINGS INTO CLEAR FLOOR SPACE OF LAVS.
  
 (13) ONE URNAL TO BE TO HDCP SPECS
 WITH AN ELONGATED RIM.
  
 (14) SOLENOID VALVE SHALL BE MOUNTED
 BELOW THE CEILING NEXT TO COOKING
 EQUIPMENT WITH SHUTOFF VALVE UP-STREAM
 OF UNION AND SOLENOID VALVE.
  
 (15) PAGE P-6 GAS RISER SAFTY RELIEF
 VALVE NOT REQUIRED.
  
 (16) GAS WILL BE ON SEPARATE PERMIT.
 GAS PERMIT APPLICATION REQUIREMENTS OF
 JULY 12, 2000 TO BE SUBMITTED.
 END OF COMMETS. CONTACT KEN STEVENS
 FOR ANY QUESTIONS. (561) 659-8096 X 8389
 AND X 8377

Review Stop Z ZONING
Rev No 1 Status P Date 2001-03-15 Cont ID  
Sent By sgraham Date 2001-03-15 Time 12:11 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***