Plan Review Details - Permit 01030064
Plan Review Stops For Permit 01030064
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2001-04-11 Cont ID  
Sent By jgomez Date 2001-04-11 Time 16:15 Rev Time 1.50
Received By jgomez Date 2001-04-10 Time 19:20 Sent To  
Notes
2001-04-11 00:00:00APPROVED WITH PROVISO:
  
 1-SINCE DOORS AND WINDOWS TO BE USED
 HAVE HURRICANE MISSILE IMPACT
 PROTECTION GLAZING, THEN, NEED TO
 PROVIDE PRODUCT APPROVAL FOR WINDOW
 MULLIONS TO BE INSTALLED AT HURRICANE
 MISSILE IMPACT PROTECTION ASSEMBLIES.
  
  
  
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT 659-8096 EXT. 8232.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status   Date   Cont ID  
Sent By jgomez Date 2001-03-23 Time 18:46 Rev Time 2.00
Received By jgomez Date   Time   Sent To  
Notes
2001-03-23 00:00:00CHECKLIST:
  
 1-NOTICE OF COMMENCEMENT IS INCOMPLETE.
 IT DOESN'T HAVE ANY INFORMATION
 REGARDING THE GENERAL DESCRIPTION OF
 IMPROVEMENTS.
 2-ARCHITECT TO REVISE THE DESIGN
 CERTIFICATION FOR BUILDING CODE
 COMPLIANCE FORM. SEE COMMENTS ON FORM.
 AND, SIGN, SEAL AND DATE FORM AS
 REQUIRED BY CHAPTER 481 FL. STATUTES.
 3-ARCHITECT TO SIGN, SEAL AND DATE THE
 ENERGY CALCULATIONS AS REQUIRED BY
 CHAPTER 471 FLORIDA STATUTES.
 4-CLARIFY HOW IS WATER RUNNING OUT OF
 THE NEW ROOF. IS THERE ANY ROOF DRAIN.
 SCUPPERS ARE SECONDARY DRAINAGE.
 5-PROVIDE COMPLETE INFORMATION FOR:
 -CONNECTION OF STEEL COLUMN AT BASE.
 -CONNECTION OF FLOOR JOISTS AND ROOF
 RAFTERS AT BOTH ENDS.
 -SPECIFY PLYWOOD SHEATHING FASTENING AS
 PER SEC 2306 CITY AMENDMENTS TO SBC/97
 6-SPECIFY THE DESIGN PRESSURES AT ALL
 EXTERIOR OPENINGS. SEC. 1606 SBC 1997.
 7-PROVIDE TWO COPIES OF CURRENT SBCCI OR
 DADE COUNTY APPROVAL FOR:
 -FLAT ROOF SYSTEM.
 -EXTERIOR DOORS AND WINDOWS (ONLY ONE
 COPY WAS SUBMITTED).
 8-PROVIDE INSTALLATION DETAILS OF IRON
 RAILING. SEC 1608.2 SBC 1997.
  
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT 659-8096 EXT. 8232.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-03-05 Cont ID  
Sent By dpalmer Date 2001-03-05 Time 17:44 Rev Time 0.00
Received By dpalmer Date 2001-03-05 Time 17:44 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-03-05 Cont ID  
Sent By jleech Date 2001-03-05 Time 07:27 Rev Time 0.25
Received By jleech Date 2001-03-05 Time 07:27 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2001-03-05 Cont ID  
Sent By jleech Date 2001-03-05 Time 07:28 Rev Time 0.25
Received By jleech Date 2001-03-05 Time 07:28 Sent To  
Notes
2001-03-05 00:00:00NO NEW PLUMBING ON THIS ADDITION.

Review Stop Z ZONING
Rev No 1 Status P Date 2001-03-12 Cont ID  
Sent By sgraham Date 2001-03-12 Time 10:17 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
2001-03-12 00:00:00MUST MEET SIDE SETBACKS


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved