Plan Review Details - Permit 01020262
Plan Review Stops For Permit 01020262 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2001-02-13 |
|
|
Cont ID |
|
Sent By |
hpiskura |
Date |
2001-02-13 |
Time |
08:37 |
Rev Time |
0.00 |
Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2001-02-20 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-02-20 |
Time |
10:31 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-02-20 |
Time |
10:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
N |
Date |
2001-03-15 |
|
|
Cont ID |
|
Sent By |
lsmith |
Date |
2001-03-15 |
Time |
15:10 |
Rev Time |
0.00 |
Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2001-03-28 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2001-03-28 |
Time |
16:20 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2001-03-28 |
Time |
16:20 |
Sent To |
|
|
Notes |
2001-03-28 00:00:00 | PLANS APPROVED BY CAPTAIN RHETT | | TURNQUEST ON MARCH 22, 2001. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2001-02-20 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2001-02-20 |
Time |
16:02 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2001-02-20 |
Time |
16:02 |
Sent To |
|
|
Notes |
2001-02-20 00:00:00 | 1) PLEASE PROVIDE INTERIOR FINISH | | CLASSIFICATION INFORMATION FOR PLANS. | | 2) PLEASE INDICATE LOCATIONS OF FIRE | | ALARM DEVICES. | | 3) PLEASE EXPLAIN IF THE DOUBLE DOORS | | THAT SWING OTWARD ARE EXITS. | | 4) NO FIRE SPRINKLER DRAWINGS PROVIDED | | WITH PLANS. | | | | CAPTAIN MIKE CARSILLO | | 659-8096,EXT.8497 | | 835-2910 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2001-03-23 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2001-03-23 |
Time |
11:18 |
Rev Time |
0.35 |
Received By |
pkrauss |
Date |
2001-03-23 |
Time |
11:02 |
Sent To |
|
|
Notes |
2001-03-23 00:00:00 | RESUB - ALL COMMENTS WERE ADDRESSED. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2001-02-27 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2001-02-21 |
Time |
11:45 |
Rev Time |
0.45 |
Received By |
pkrauss |
Date |
2001-02-21 |
Time |
11:44 |
Sent To |
|
|
Notes |
2001-02-21 00:00:00 | *******************DENIED*************** | | | | MECHANICAL PERMIT REQUIRED. | | | | NOTE:AS PER 1997 SMC 609.1.1 THERE | | SHALL BE NO COMBUSTIBLES ABOVE CEILING | | IN RETURN AIR PLENUM. | | | | AS PER 1997 SMC 304.8.6.1 OVER FLOW | | PROTECTION IS REQUIRED FOR DX-2. | | | | PROVIDE INFORMATION FOR BACKFLOW | | PREVENTION DRAWING M-4, NOTE 16 THRU 18. | | | | PROVIDE AIR BALANCE SCHEDULE AS WELL AS | | OUTSIDE AIR CALCULATIONS TO SHOW | | COMPLIANCE WITH ASHRAE 62-89. | | | | AS PER 1997 SMC 609.1.1 - DUCT SMOKE | | DETECTORS REQUIRED FOR FAN SHUT DOWN | | WITH NOTIFICATION TO ALARM/STROBE AS | | PER NFPA 90A 4-4.4.3. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2001-02-27 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2001-02-27 |
Time |
12:50 |
Rev Time |
0.50 |
Received By |
jleech |
Date |
2001-02-27 |
Time |
12:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2001-03-15 |
|
|
Cont ID |
|
Sent By |
lsmith |
Date |
2001-03-15 |
Time |
15:10 |
Rev Time |
0.00 |
Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
|