Plan Review Details - Permit 01010952
Plan Review Stops For Permit 01010952
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2002-01-31 Cont ID  
Sent By lmartine Date 2002-01-31 Time 17:41 Rev Time 1.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2001-01-30 Cont ID  
Sent By jwitmer Date 2001-01-30 Time 08:18 Rev Time 0.75
Received By jwitmer Date   Time   Sent To  
Notes
2001-01-30 00:00:00PROVISO: SBC 705.1.3.2.3
 EXIT ACCESS DOORS ARE TO BE FIRE RATED
 AND TO BE SELF CLOSING.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2002-01-22 Cont ID  
Sent By dpalmer Date 2002-01-22 Time 13:41 Rev Time 0.00
Received By dpalmer Date 2002-01-22 Time 13:41 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2001-02-20 Cont ID  
Sent By dpalmer Date 2001-02-20 Time 13:04 Rev Time 0.00
Received By dpalmer Date 2001-02-20 Time 13:04 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2001-01-31 Cont ID  
Sent By dpalmer Date 2001-01-31 Time 12:00 Rev Time 0.00
Received By dpalmer Date 2001-01-31 Time 12:00 Sent To  
Notes
2001-01-31 00:00:00****************** UNSAT ***********
  
 1)NOTE: PLEASE SHOW ALL BRANCH CIRCUIT
 #`S ON PLANS AND CORRELATE WITH PANEL
 SCHEDULES.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2001-02-28 Cont ID  
Sent By jwitmer Date 2001-02-28 Time 14:03 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2002-01-15 Cont ID  
Sent By mcarsill Date 2002-01-15 Time 08:51 Rev Time 0.00
Received By mcarsill Date 2002-01-15 Time 08:51 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2001-01-23 Cont ID  
Sent By mcarsill Date 2001-01-23 Time 10:10 Rev Time 0.00
Received By mcarsill Date 2001-01-23 Time 10:10 Sent To  
Notes
2001-01-23 00:00:001) NO INTERIOR FINISH INFORMATION
 COULD BE LOCATED FOR PLANS. INTERIOR
 FINISH ON WALLS AND CEILINGS IN EXITS
 TO BE CLASS A OR B. IN OFFICE AREAS, THE
 INTERIOR FINISH TO BE CLASS A,B OR C.
 2) THE 3/4 DOORS TO BE EQUIPPED WITH
 SELF-CLOSING DEVICES.
 3) SINCE THIS IS AN EXISTING BUILDING,
 MINIMUM HEADROOM SHALL BE SEVEN FEET
 AND ANY PROJECTION FROM THE CEILING
 SHALL BE NOT LESS THAN SIX FOOT EIGHT.
  
 CAPTAIN MIKE CARSILLO
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2002-01-24 Cont ID  
Sent By pkrauss Date 2002-01-24 Time 12:03 Rev Time 0.25
Received By pkrauss Date 2002-01-24 Time 12:03 Sent To  
Notes
2002-01-24 00:00:00NO MECHANICAL SUBMITTED FOR REVISION.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2001-01-30 Cont ID  
Sent By ndenmark Date 2001-01-30 Time 08:35 Rev Time 0.25
Received By ndenmark Date 2001-01-30 Time 08:35 Sent To  
Notes
2001-01-30 00:00:00INSUFFICIENT INFORMATION TO REVIEW.
  
 MECHANICAL CONTRACTOR TO PROVIDE PLANS
 AT TIME OF MECHANICAL PERMIT
 APPLICATION, PRIOR TO ANY MECHANICAL
 WORK BEING DONE.

Review Stop P PLUMBING
Rev No 3 Status P Date 2002-01-22 Cont ID  
Sent By kstevens Date 2002-01-22 Time 17:58 Rev Time 0.50
Received By kstevens Date 2002-01-22 Time 17:57 Sent To  
Notes
2002-01-22 00:00:00REVISIONS OK ADDED SINKS (3) REMOVE
 FUTURE MOP SINK - CHANGE TOILET ROOM LAY
 OUT - MOVE DRINKING FOUNTAIN.

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-02-28 Cont ID  
Sent By jleech Date 2001-02-28 Time 14:04 Rev Time 0.50
Received By jleech Date 2001-02-28 Time 14:04 Sent To  
Notes
2001-02-28 00:00:00PROVISO; AS MARKED ON PLANS.

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-01-25 Cont ID  
Sent By jleech Date 2001-01-25 Time 11:45 Rev Time 0.75
Received By jleech Date 2001-01-25 Time 11:45 Sent To  
Notes
2001-01-25 00:00:001.FLOOR DRAINS IN RESTROOMS SHALL BE 3"
 PER 94 SPC 409.4.1.1.
  
 2.MECHANICAL WATER HAMMER ARRESTERS
 SHALL BE INSTALLED.SEC 607.8.2 AND
 MUSTBE ACCESEIBLE. SEC.607.8.3.
  
 3.BREAK ROOM SINK SHALL COMPLY WITH 97
 FACBC SEC. 4.24.1 THRU 4.24.7.
  
 PLUMBING PLAN REVIEW BY
 JOHN LEECH
 659-8096 8377

Review Stop Z ZONING
Rev No 1 Status N Date 2001-02-28 Cont ID  
Sent By jwitmer Date 2001-02-28 Time 14:02 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***