Plan Review Stops For Permit 01010897 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2001-07-05 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2001-07-05 |
Time |
17:23 |
Rev Time |
0.75 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-07-05 00:00:00 | REVISION #1 6/20/01 JW |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2001-02-16 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2001-02-16 |
Time |
11:17 |
Rev Time |
0.75 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2001-01-29 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2001-01-29 |
Time |
11:06 |
Rev Time |
3.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-29 00:00:00 | CONTRACTOR: GEN-X CONSTRUCTION | | 2419 S DIXIE HWY | | 1)- FL. ACCESIBILITY CODE 4.1.6.1(C)- | | IF ALTERATIONS OF SINGLE ELEMEMNTS, WHEN | | CONSIDERED TOGETHER, AMOUNT TO AN ALTER- | | ATION OF A ROOM OR SPACE IN A BUILDING | | OR FACILITY, THE ENTIRE SPACE SHALL BE | | MADE ACCESIBLE. THE MENS RESTROOM DOES | | NOT MEET THE CURENT HANDICAPPED ACCESS- | | IBILITY CODE. | | 2)-FL. ACCESSIBILITY CODE 4.1.6.2.2- | | DISPROPORTIONATE COST SEE ATTACHMENT OF | | PRIORITIES IN CHOOSING WHAT ELEMENTS | | GIVE THE GREATEST ACCESS IN THE FOLLOW- | | ING ORDER.20 %OF CONTTRACT VALUE IS | | WHAT IS REQUIRED PER IMPROVEMENT. | | 3)- FL ACC. 4.13.5 MENS RESTROOM WILL | | REQUIRE A MINIMUM CLEAR OPENING OF 32". | | 4)- FL ACC.4.13.6 MANEUVERING CLEARANCES | | AT DOORWAYS, THERE ISN'T ENOUGH CLEAR | | TURNING SPACE TO MEET THE 60" DIAMETER | | SPHERE. | | 5)- FL ACC 4.13.9 DOOR HARDWARE REQUIRES | | LEVER-OPERATED MECHANISMS,PUSH-TYPE MECH | | ANISMS AND U-SHAPED HANDLES ARE ACCEPT- | | ABLE DESIGNS. | | 6)- FIRE ZONE: THIS BUILDING IS LOCATED | | IN A FIRE ZONE. F102.1 NO WOOD IS ALLOW- | | ED INEXTERIOR WALLS (F102.1) NO WOOD | | ALLOWED IN EXTERIOR WALLS.SEE SEC. 1/3. | | 7)- SEC. A-3, 2/3: F105.12 WOOD VENEERS | | DO NOT CONFORM WITH SBC 1403.6.7. | | 8)- SBC 1606.2A VELOCITY PRESSURE FOR | | WINDOWS NOT GIVEN. | | | | BUILDING PLAN REVIEW | | JIM WITMER | | (561) 659-8096 EX 8412 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2001-07-31 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-07-31 |
Time |
10:23 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-07-31 |
Time |
10:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2001-01-31 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-01-31 |
Time |
17:11 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-01-31 |
Time |
17:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2001-06-22 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2001-06-22 |
Time |
09:42 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2001-06-22 |
Time |
09:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2001-02-07 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2001-02-07 |
Time |
14:56 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2001-02-07 |
Time |
14:56 |
Sent To |
|
|
Notes |
2001-02-07 00:00:00 | 1) AWNING MATERIAL TO BE FIRE RETARDENT. | | 2) PLEASE PROVIDE INTERIOR FINISH | | CLASSIFICATION INFORMATION. | | | | CAPTAIN MIKE CARSILLO | | 659-8096,EXT.8497 | | 835-2910 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2001-02-06 |
|
|
Cont ID |
|
Sent By |
ndenmark |
Date |
2001-02-06 |
Time |
11:42 |
Rev Time |
0.33 |
Received By |
ndenmark |
Date |
2001-02-06 |
Time |
11:42 |
Sent To |
|
|
Notes |
2001-02-06 00:00:00 | PROVISO: | | EXISTING DUCT WORK TO BE REUSED TO BE | | INSPECTED FOR CLEANLINESS AND, IF | | DEEMED NEEDED CLEANED AND SANITIZED. | | PROVIDE ACCESS FOR THE MECHANICAL | | INSPECTOR TO INSPECT DUCT. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2001-07-29 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2001-07-29 |
Time |
09:30 |
Rev Time |
1.00 |
Received By |
pschmitz |
Date |
2001-07-29 |
Time |
09:29 |
Sent To |
|
|
Notes |
2001-07-29 00:00:00 | PROVISO; | | WATER COOLER SPECIFIED DOES NOT HAVE A | | DRAIN BUT IT IS SUPPLIED WITH CITY WATER | | FIELD INSPECTION SHALL CHECK FOR | | COMPLIANCE. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2001-06-29 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2001-06-29 |
Time |
09:48 |
Rev Time |
0.33 |
Received By |
pschmitz |
Date |
2001-06-29 |
Time |
09:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2001-06-19 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
2001-06-19 |
Time |
10:20 |
Rev Time |
1.00 |
Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-06-19 00:00:00 | PLUMBING PLAN REVIEW PROVISO | | CORDLEY/TEMPRITE POINT OF USE WATER | | COOLER, ECLIPSE-SS. | | DIRECT WATER CONNECTION, NO DRAIN,WITH | | CUP DISPENSER,SEE FROM MFG. RE: ADA | | FACBC-97 SEC 4.15.1,4.27.4 | | END OF COMMENTSPAUL SCHMITZ | | QUESTIONS561-659-8096X8233 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2001-01-31 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2001-01-31 |
Time |
14:18 |
Rev Time |
0.50 |
Received By |
jleech |
Date |
2001-01-31 |
Time |
14:18 |
Sent To |
|
|
Notes |
|
|