Plan Review Details - Permit 01010736
Plan Review Stops For Permit 01010736
Review Stop E ELECTRICAL
Rev No 6 Status P Date 2001-11-16 Cont ID  
Sent By dpalmer Date 2001-11-16 Time 08:19 Rev Time 0.00
Received By dpalmer Date 2001-11-16 Time 08:19 Sent To  
Notes
2001-11-16 00:00:00******** NOTE********
  
 ELECTRICAL OK FOR MAIN HOUSE ONLY.
 NO SERVICE.

Review Stop E ELECTRICAL
Rev No 5 Status F Date 2001-11-13 Cont ID  
Sent By dpalmer Date 2001-11-13 Time 13:13 Rev Time 0.00
Received By dpalmer Date 2001-11-13 Time 13:13 Sent To P
Notes
2001-11-13 00:00:00****************** UNSAT **************
  
 1)NOTE: PLEASE NOTE THAT PLANS DO NOT
 CORRELATE WITH OTHER ELEC FOR GUESTHOUSE
 /GARAGE PLANS.
  
 2)NOTE: PLEASE NOTE THAT GARAGE IS NOT
 SHOWN?
  
 3)NOTE: PLEASE NOTE THAT CONDUCTOR SIZES
 DO NOT MEET 310-16. 200A DISC AND PANEL
 WITH WIRE FOR 100AMPS? 310-15. W/ #6
 NEUTRAL.
  
 4)NOTE: PLEASE CLARFIY SIZE OF METERCAN
 PER LOAD CALCULATIONS, LOAD SHOWN AT
 269.9 AMPS.
  
 5)NOTE: PLEASE SHOW MEANS OF GROUNDING
 AT DETACHED HOUSE FROM MAIN SERVICE PER
 250-32. BLDG STEEL AND COLD WATER(IF
 METAL).
 6)NOTE: PLEASE SHOW EQUIPMENT GROUNDING
 CONDUCTOR FROM MAIN DISCONNECTS TO PANEL
 S AT GUEST HOUSE AND MAIN HOUSE. PER
 250-122./250-32
  
 7)NOTE: PLEASE INDICATE MAIN HOUSE WITH
 MAIN CIRCUIT BRKR PER 225-31 DETACHED
 FROM GARAGE/GUEST HOUSE.
  
 PLEASE MAKE THE ABOVE CORRECTIONS AND
 SUBMIT THE ABOVE INFORMATION FOR REVIEW
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
 PLEASE CALL TO SET UP A MEETING IF
 NEEDED.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2001-11-06 Cont ID  
Sent By dpalmer Date 2001-11-06 Time 21:00 Rev Time 0.00
Received By dpalmer Date 2001-11-06 Time 21:00 Sent To B
Notes
2001-11-06 00:00:00**************** UNSAT ****************
  
 1)NOTE: PLEASE NOTE THAT OUTLETS FOR
 ISLAND ARE STILL NOT SHOWN AS GFI?
 210-8-A-6
  
 2)NOTE: PLEASE NOTE THAT AIC RATINGS FOR
 EQUIPMENT ARE STILL NOT SHOWN?? 110-9
  
 3)NOTE: PLEASENOTE THAT RISER DIAGRAM
 DOES NOT CORRELATE WITH NOTE SUBMITTED
 AT THE BOTTOM OF PLANS ON A-9.
 GARAGE PANEL, GROUNDING ETC.
  
 4)NOTE: PLEASE NOTE MISSING OUTLETS FOR
 KITCHEN COUNTERSPACE.210-52-C-1.
  
 PLEASE SUBMIT THE ABOVE FOR REVIEW.
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2001-10-11 Cont ID  
Sent By dpalmer Date 2001-10-11 Time 09:50 Rev Time 0.00
Received By dpalmer Date 2001-10-11 Time 09:50 Sent To  
Notes
2001-10-11 00:00:00***************** UNSAT *************
  
 1)NOTE: PLEASE NOTE THAT NOTE ON PLAN
 MENTIONS SUB PANELS ETC. AND RISER
 DIAGRAM DOES NOT SHOW ANY OF THESE ITEMS
 ?? PLEASE SHOW, WIRE CONDUIT, DISC FOR
 GARAGE (DETACHED)??
  
 2) NOTE: PLEASE SHOW ALL OUTLETS SERVING
 KITCHEN COUNTERSPACE AS GFI/GFI PROTECT-
 -ED PER 210-8-A-6.
 INCLUDING KITCHEN ISLAND.
  
 3)NOTE: PLEASE NOTE MISSING OUTLETS PER
 210-52
  
 4)NOTE: PLEASE ALSO NOTE THE NOTE ON
 PLANS ALSO NOTES AVAILABLR FAULT CURRENT
 BUT DOES NOT SHOW THE ACTUAL RATING OF
 EQUIPMNET. PLEASE SHOW 110-9/215-5
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2001-03-12 Cont ID  
Sent By dpalmer Date 2001-03-12 Time 18:16 Rev Time 0.00
Received By dpalmer Date 2001-03-12 Time 18:16 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2001-01-25 Cont ID  
Sent By dpalmer Date 2001-01-25 Time 20:45 Rev Time 0.00
Received By dpalmer Date 2001-01-25 Time 20:44 Sent To  
Notes
2001-01-25 00:00:00***************** UNSAT ***************
  
 1)NOTE: PLEASE NOTE THAT PER F.A.C SEC.
 481.221 PLANS ARE TO BE SIGNED AND
 SEALED BY THE ARCHITECT OF RECORD.
 PLEASE NOTE THAT ALL SHEETS THAT
 CONTAIN TITLE BLOCK.
  
 2) NOTE: SMOKE DETECTORS ARE REQUIRED
 INSIDE AND OUTSIDE ALL SLEEPING ROOMS.
 ALSO ON EACH LEVEL OF A MULTI-LEVEL
 DWELLING UNIT. ROOMS WITH BATHS AND OR
 CLOSETS ARE CONSIDERED SLEEPING ROOMS.
 PER NFPA-72 2-2.1.1.1.
  
 3) PLEASE NOTE MISSING OUTLET FOR A/C
 EQUIPMENT PER 210-63 OF NEC AND 309.1
 MECHANICAL CODE. UPSTAIRS
  
 4) NOTE: PLEASE SHOW GROUNDING
 ELECTRODEGOING TO BUILDING STEEL AND
 COLD WATER
 PER 250-50.
  
 5) NOTE: PLEASE LIST THE REQ`D BATH(S)
 CIRCUIT(S) PER 210-11-C-3.
 MUST BE 20A AND #12AWG.
  
 6) NOTE: PLEASE SHOW ALL OUTLETS
 SERVINGKITCHEN COUNTERSPACE AS GFI/GFI
 PROTECT--ED PER 210-8-A-6.
  
 7)NOTE: PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW EQUIPMENT BEING INSTALLED.
 MAINS/PANELS/BREAKERS MUST BE RATED FOR
 THE AVAILABLE FAULT CURRNET PER 110-9.
  
 8)NOTE: PLEASE SHOW AND CLARIFY WHERE
 POWER FOR NEW GARAGE IS COMING FROM???
  
  
 PLEASE SUBMIT ALL THE ABOVE INFORMATION
 FOR REVIEW. IF THERE ARE ANY QUESTIONS
 PLEASE CALL.
  
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop M MECHANICAL (A/C)
Rev No 3 Status N Date 2001-03-19 Cont ID  
Sent By jleech Date 2001-03-19 Time 14:41 Rev Time 0.25
Received By jleech Date 2001-03-19 Time 14:41 Sent To  
Notes
2001-03-19 00:00:00A/C DRAWINGS REQUIRED WITH A/C
 APPLICATION.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2001-03-13 Cont ID  
Sent By jleech Date 2001-03-13 Time 07:06 Rev Time 0.50
Received By jleech Date 2001-03-13 Time 07:05 Sent To  
Notes
2001-03-13 00:00:00DENIED;
  
 HAVE MECHANICAL CONTRACTOR (SASSO) WHO
 IS LISTED ON PERMIT APPLICATION, DRAW
 UP PLANS AND SUBMIT FOR APPROVAL.
  
 ANY QUESTIONS CALL 659-8096 EXT. 8377

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2001-01-23 Cont ID  
Sent By jleech Date 2001-01-23 Time 18:08 Rev Time 0.25
Received By jleech Date 2001-01-23 Time 18:08 Sent To  
Notes
2001-01-23 00:00:00NO A/C PLAN WITH DRAWINGS BUT HAS A/C
 PERMIT NUMBER 01010744.

Review Stop P PLUMBING
Rev No 3 Status F Date 2001-11-14 Cont ID  
Sent By kstevens Date 2001-11-14 Time 18:19 Rev Time 0.50
Received By kstevens Date 2001-11-14 Time 18:19 Sent To  
Notes
2001-11-14 00:00:00DENIED
 REFERENCE: SPC-94
  
 1) REVISED SANITARY RISER DIAGRAM IS RE-
 QUIRED FOR REVISION OF NEW ISLAND SINK
 IN KITCHEN.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377.

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-10-16 Cont ID  
Sent By dpalmer Date 2001-11-13 Time 13:13 Rev Time 0.50
Received By kstevens Date 2001-10-16 Time 09:35 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2001-01-23 Cont ID  
Sent By jleech Date 2001-01-23 Time 18:10 Rev Time 0.25
Received By jleech Date   Time 18:10 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 4 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2001-10-30 Cont ID  
Sent By rmcdouga Date 2001-10-30 Time 11:10 Rev Time 2.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-11-15 00:00:00REVISION DENIED
  
 1) PROVIDE EMERGENCY ESCAPE AND EXIT
 OPENING IN SECOND FLOOR GUEST ROOM PER
 97 SBC SECTION 1005.4.1. THE MINIMUM
 NETCLEAR OPENING AREA SHALL BE 5.7
 SQ.FT., THE MINIMUM NET CLEAR OPENING
 HEIGHT OF 24" AND WIDTH OF 20" (SECT.
 1005.4.4) & SILL HEIGHT OF NOT MORE
 THAN 44"
 (SECT. 1005.4.3).
  
 2) INDICATE ACCESS TO ATTIC ACCESS TO
 COMPLY WITH 97 SBC SECT. 2309.6.
  
 3)PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR:
 - STRUCTURAL WINDOW MULLIONS
 - STORM PANELS FOR FRENCH DOORS
  
 4) EXTERIOR EXITWAY STAIRS:
 - EXTERIOR STAIRS SHALL BE SEPARATED
 FROM THE INTERIOR OF THE BUILDING BY
 WALLS WITH A FIRE RESISTANCE RATING OF
 NOT LESS THAN ONE HOUR, WITH FIXED OR
 SELF-CLOSING OPENING PROTECTIVES AS
 REQUIRED FOR ENCLOSED STAIRS. THIS
 PROJECTION SHALL EXTEND VERTICALLY FROM
 THE GROUND TO A POINT 10 FT. ABOVE THE
 TOPMOST LANDING OR THE ROOF LINE,
 WHICH-EVER IS LOWER AND HORIZONTALLY 10
 FT.
 FROM EACH SIDE OF THE STAIRWAY.
 OPENINGSWITHIN THE 10 FT. HORIZONTAL
 EXTENSION
 OF THE PROTECTED WALLS BEYOND THE
 STAIRWAY SHALL BE EQUIPPED WITH FIXED
 3/4- HOUR ASSEMBLIES.
 (97 SBC SEC. 1006.2.4) THE NEW WINDOWS
 AND DOORS AT STAIRS MUST COMPLY.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202
2001-10-30 00:00:00************BUILDING PROVISO************
  
 1) PROVIDE MANUFACTURES SPECIFICATIONS,
 UL LISTING INFORMATION, STRUCTURAL
 DRAWINGS AND ELEVATION DRAWINGS FOR
 VENTLESS FIRE BOX PRIOR TO INSTALLATION.
 INSTALLATION MUST COMPLY WITH CHAPTER 9
 OF THE 97 STANDARD MECHICAL CODE.
 A SEPARATE GAS PERMIT WILL BE REQUIRED
 IF USING A GAS APPLIANCE IN FIRE BOX.
  
 2) PROVIDE PRODUCT APPROVALS FOR DOUBLE
 INSWING ENTRY DOORS WITH SIDELITES,
 PRIOR TO INSTALLATION. UNIT MUST COMPLY
 WITH LARGE MISSLE IMPACT PROTECTION
 REQUIREMENTS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202
  
 REVISION WAS RESUBMITTED ON 11-8-01 FOR
 PLBG. AND ELEC. THE ITEMS REQUESTED IN
 ABOVE PROVISO WERE ADDRESSED.
 RM 11-15-01

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2001-03-19 Cont ID  
Sent By fknapp Date 2001-03-19 Time 14:37 Rev Time 4.00
Received By fknapp Date 2001-03-19 Time 14:37 Sent To  
Notes
2001-03-19 00:00:00 
  
 ************BUILDING PROVISO************
  
 SBC 104.2.2
  
 1) PROVIDE 2 CURRENT COMPLETE COPIES OF
 SBCCI OR METRO DADE PRODUCT APPROVALS
 FOR:
 SLIDING GLASS DOORS
 CIRCLE TOP WINDOWS
  
 ANY QUESTIONS PLEASE CALL,
 FRANK KNAPP
 BUILDING PLAN REVIEW
 DEPARTMENT OF CONSTRUCTION SERVICES
 CITY OF WEST PALM BEACH
 (561) 659-8096 EXT. 8392

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2001-02-27 Cont ID  
Sent By fknapp Date 2001-02-27 Time 08:44 Rev Time 5.00
Received By fknapp Date 2001-02-27 Time 08:43 Sent To  
Notes
2001-02-27 00:00:00 
 *************BUILDING UNSAT*************
  
 SBC 104.2.2
  
 1) PROVIDE PLANS THAT HAVE RAISED SEAL
 AND ORIGINAL SIGNATURE OF DESIGNER OF
 RECORD.
  
 2) PROVIDE STORM PANEL INFORMATION WITH
 INSTALLATION SCHEDULE AND KEY PLAN WITH
 SPECIFIC ANCHORS AND MOUNTING TO BE USED
 FOR ALL NON-IMPACT GLAZING.
  
 3) PROVIDE SOIL TEST PER SEC. 1804.2.2
 OF CITY AMENDMENTS TO 1997 SBC.
  
 4) PROVIDE 2 CURRENT COMPLETE COPIES OF
 SBCCI OR METRO DADE PRODUCT APPROVALS
 FOR:
 FRONT INSWING ENTRY DOOR W/ SIDELITE
 SLIDING GLASS DOORS
 SH WINDOWS
 CIRCLE TOP WINDOWS
  
 5) PROVIDE FLOOD ZONE ELEVATION
 CERTIFICATE FOR NEW CONSTRUTION WITH BFE
  
 6) PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
  
 7) STRUCTUAL NOTES, LATERAL LOADS REF.94
 SBC ON SHT A3 94 SBC IS NOT CURRENT.
  
 8) EGRESS NOTE ON SHT A4 REF. NET CLEAR
 OPENING OF NOT LESS THAN 4 SQUARE FEET,
 EGRESS WINDOWS MUST BE GREATER THAN 4
 SQUARE FEET.
  
 9) STAIR DETAIL ON SHT A10 REF. 94 SBC,
 94 SBC US NOT CURRENT, STAIRS MUST
 COMPLY WITH 97 SBC 1006, 1007 AND 1015.
 PICKETS MUST BE SPACE SO THAT A 4"
 SPHERE CANNOT PAST THROUGH ANY OPENING.
  
 10) PROVIDE COMPLETE LINTEL TBL. ON SHT.
 A12
  
 11) IDENTIFY LOCATION OF CONNECTORS
 FROM CONNECTOR SCHEDULE TO BE USED ON
 SHT. A12 & A13 FRAMING PLANS.
  
 12) BEFORE A PERMIT TO CONSTRUCT CAN BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH CO.,THE PERMIT PLANS STAMPED BY
 THEM AND THE RECEIPT ATTACHED TO THE
 PERMIT APPLICATION.
  
 ANY QUESTIONS PLEASE CALL,
 FRANK KNAPP
 BUILDING PLAN REVIEW
 DEPARTMENT OF CONSTRUCTION SERVICES
 CITY OF WEST PALM BEACH
 (561) 659-8096 EXT. 8392

Review Stop Z ZONING
Rev No 2 Status P Date 2001-10-22 Cont ID  
Sent By sgraham Date 2001-10-22 Time 12:18 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2001-01-23 Cont ID  
Sent By sgraham Date 2001-01-23 Time 13:31 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***