Plan Review Stops For Permit 01010736 |
Review Stop |
E |
ELECTRICAL |
Rev No |
6 |
Status |
P |
Date |
2001-11-16 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-11-16 |
Time |
08:19 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-11-16 |
Time |
08:19 |
Sent To |
|
|
Notes |
2001-11-16 00:00:00 | ******** NOTE******** | | | | ELECTRICAL OK FOR MAIN HOUSE ONLY. | | NO SERVICE. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
F |
Date |
2001-11-13 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-11-13 |
Time |
13:13 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-11-13 |
Time |
13:13 |
Sent To |
P |
|
Notes |
2001-11-13 00:00:00 | ****************** UNSAT ************** | | | | 1)NOTE: PLEASE NOTE THAT PLANS DO NOT | | CORRELATE WITH OTHER ELEC FOR GUESTHOUSE | | /GARAGE PLANS. | | | | 2)NOTE: PLEASE NOTE THAT GARAGE IS NOT | | SHOWN? | | | | 3)NOTE: PLEASE NOTE THAT CONDUCTOR SIZES | | DO NOT MEET 310-16. 200A DISC AND PANEL | | WITH WIRE FOR 100AMPS? 310-15. W/ #6 | | NEUTRAL. | | | | 4)NOTE: PLEASE CLARFIY SIZE OF METERCAN | | PER LOAD CALCULATIONS, LOAD SHOWN AT | | 269.9 AMPS. | | | | 5)NOTE: PLEASE SHOW MEANS OF GROUNDING | | AT DETACHED HOUSE FROM MAIN SERVICE PER | | 250-32. BLDG STEEL AND COLD WATER(IF | | METAL). | | 6)NOTE: PLEASE SHOW EQUIPMENT GROUNDING | | CONDUCTOR FROM MAIN DISCONNECTS TO PANEL | | S AT GUEST HOUSE AND MAIN HOUSE. PER | | 250-122./250-32 | | | | 7)NOTE: PLEASE INDICATE MAIN HOUSE WITH | | MAIN CIRCUIT BRKR PER 225-31 DETACHED | | FROM GARAGE/GUEST HOUSE. | | | | PLEASE MAKE THE ABOVE CORRECTIONS AND | | SUBMIT THE ABOVE INFORMATION FOR REVIEW | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | PLEASE CALL TO SET UP A MEETING IF | | NEEDED. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
F |
Date |
2001-11-06 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-11-06 |
Time |
21:00 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-11-06 |
Time |
21:00 |
Sent To |
B |
|
Notes |
2001-11-06 00:00:00 | **************** UNSAT **************** | | | | 1)NOTE: PLEASE NOTE THAT OUTLETS FOR | | ISLAND ARE STILL NOT SHOWN AS GFI? | | 210-8-A-6 | | | | 2)NOTE: PLEASE NOTE THAT AIC RATINGS FOR | | EQUIPMENT ARE STILL NOT SHOWN?? 110-9 | | | | 3)NOTE: PLEASENOTE THAT RISER DIAGRAM | | DOES NOT CORRELATE WITH NOTE SUBMITTED | | AT THE BOTTOM OF PLANS ON A-9. | | GARAGE PANEL, GROUNDING ETC. | | | | 4)NOTE: PLEASE NOTE MISSING OUTLETS FOR | | KITCHEN COUNTERSPACE.210-52-C-1. | | | | PLEASE SUBMIT THE ABOVE FOR REVIEW. | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2001-10-11 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-10-11 |
Time |
09:50 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-10-11 |
Time |
09:50 |
Sent To |
|
|
Notes |
2001-10-11 00:00:00 | ***************** UNSAT ************* | | | | 1)NOTE: PLEASE NOTE THAT NOTE ON PLAN | | MENTIONS SUB PANELS ETC. AND RISER | | DIAGRAM DOES NOT SHOW ANY OF THESE ITEMS | | ?? PLEASE SHOW, WIRE CONDUIT, DISC FOR | | GARAGE (DETACHED)?? | | | | 2) NOTE: PLEASE SHOW ALL OUTLETS SERVING | | KITCHEN COUNTERSPACE AS GFI/GFI PROTECT- | | -ED PER 210-8-A-6. | | INCLUDING KITCHEN ISLAND. | | | | 3)NOTE: PLEASE NOTE MISSING OUTLETS PER | | 210-52 | | | | 4)NOTE: PLEASE ALSO NOTE THE NOTE ON | | PLANS ALSO NOTES AVAILABLR FAULT CURRENT | | BUT DOES NOT SHOW THE ACTUAL RATING OF | | EQUIPMNET. PLEASE SHOW 110-9/215-5 | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2001-03-12 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-03-12 |
Time |
18:16 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-03-12 |
Time |
18:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2001-01-25 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-01-25 |
Time |
20:45 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-01-25 |
Time |
20:44 |
Sent To |
|
|
Notes |
2001-01-25 00:00:00 | ***************** UNSAT *************** | | | | 1)NOTE: PLEASE NOTE THAT PER F.A.C SEC. | | 481.221 PLANS ARE TO BE SIGNED AND | | SEALED BY THE ARCHITECT OF RECORD. | | PLEASE NOTE THAT ALL SHEETS THAT | | CONTAIN TITLE BLOCK. | | | | 2) NOTE: SMOKE DETECTORS ARE REQUIRED | | INSIDE AND OUTSIDE ALL SLEEPING ROOMS. | | ALSO ON EACH LEVEL OF A MULTI-LEVEL | | DWELLING UNIT. ROOMS WITH BATHS AND OR | | CLOSETS ARE CONSIDERED SLEEPING ROOMS. | | PER NFPA-72 2-2.1.1.1. | | | | 3) PLEASE NOTE MISSING OUTLET FOR A/C | | EQUIPMENT PER 210-63 OF NEC AND 309.1 | | MECHANICAL CODE. UPSTAIRS | | | | 4) NOTE: PLEASE SHOW GROUNDING | | ELECTRODEGOING TO BUILDING STEEL AND | | COLD WATER | | PER 250-50. | | | | 5) NOTE: PLEASE LIST THE REQ`D BATH(S) | | CIRCUIT(S) PER 210-11-C-3. | | MUST BE 20A AND #12AWG. | | | | 6) NOTE: PLEASE SHOW ALL OUTLETS | | SERVINGKITCHEN COUNTERSPACE AS GFI/GFI | | PROTECT--ED PER 210-8-A-6. | | | | 7)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | ALL NEW EQUIPMENT BEING INSTALLED. | | MAINS/PANELS/BREAKERS MUST BE RATED FOR | | THE AVAILABLE FAULT CURRNET PER 110-9. | | | | 8)NOTE: PLEASE SHOW AND CLARIFY WHERE | | POWER FOR NEW GARAGE IS COMING FROM??? | | | | | | PLEASE SUBMIT ALL THE ABOVE INFORMATION | | FOR REVIEW. IF THERE ARE ANY QUESTIONS | | PLEASE CALL. | | | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
N |
Date |
2001-03-19 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2001-03-19 |
Time |
14:41 |
Rev Time |
0.25 |
Received By |
jleech |
Date |
2001-03-19 |
Time |
14:41 |
Sent To |
|
|
Notes |
2001-03-19 00:00:00 | A/C DRAWINGS REQUIRED WITH A/C | | APPLICATION. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2001-03-13 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2001-03-13 |
Time |
07:06 |
Rev Time |
0.50 |
Received By |
jleech |
Date |
2001-03-13 |
Time |
07:05 |
Sent To |
|
|
Notes |
2001-03-13 00:00:00 | DENIED; | | | | HAVE MECHANICAL CONTRACTOR (SASSO) WHO | | IS LISTED ON PERMIT APPLICATION, DRAW | | UP PLANS AND SUBMIT FOR APPROVAL. | | | | ANY QUESTIONS CALL 659-8096 EXT. 8377 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2001-01-23 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2001-01-23 |
Time |
18:08 |
Rev Time |
0.25 |
Received By |
jleech |
Date |
2001-01-23 |
Time |
18:08 |
Sent To |
|
|
Notes |
2001-01-23 00:00:00 | NO A/C PLAN WITH DRAWINGS BUT HAS A/C | | PERMIT NUMBER 01010744. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2001-11-14 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2001-11-14 |
Time |
18:19 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2001-11-14 |
Time |
18:19 |
Sent To |
|
|
Notes |
2001-11-14 00:00:00 | DENIED | | REFERENCE: SPC-94 | | | | 1) REVISED SANITARY RISER DIAGRAM IS RE- | | QUIRED FOR REVISION OF NEW ISLAND SINK | | IN KITCHEN. | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2001-10-16 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-11-13 |
Time |
13:13 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2001-10-16 |
Time |
09:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2001-01-23 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2001-01-23 |
Time |
18:10 |
Rev Time |
0.25 |
Received By |
jleech |
Date |
|
Time |
18:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
4 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
3 |
Status |
P |
Date |
2001-10-30 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2001-10-30 |
Time |
11:10 |
Rev Time |
2.00 |
Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-11-15 00:00:00 | REVISION DENIED | | | | 1) PROVIDE EMERGENCY ESCAPE AND EXIT | | OPENING IN SECOND FLOOR GUEST ROOM PER | | 97 SBC SECTION 1005.4.1. THE MINIMUM | | NETCLEAR OPENING AREA SHALL BE 5.7 | | SQ.FT., THE MINIMUM NET CLEAR OPENING | | HEIGHT OF 24" AND WIDTH OF 20" (SECT. | | 1005.4.4) & SILL HEIGHT OF NOT MORE | | THAN 44" | | (SECT. 1005.4.3). | | | | 2) INDICATE ACCESS TO ATTIC ACCESS TO | | COMPLY WITH 97 SBC SECT. 2309.6. | | | | 3)PROVIDE (2) CURRENT AND COMPLETE | | COPIES OF SBCCI OR METRO-DADE PRODUCT | | APPROVALS FOR: | | - STRUCTURAL WINDOW MULLIONS | | - STORM PANELS FOR FRENCH DOORS | | | | 4) EXTERIOR EXITWAY STAIRS: | | - EXTERIOR STAIRS SHALL BE SEPARATED | | FROM THE INTERIOR OF THE BUILDING BY | | WALLS WITH A FIRE RESISTANCE RATING OF | | NOT LESS THAN ONE HOUR, WITH FIXED OR | | SELF-CLOSING OPENING PROTECTIVES AS | | REQUIRED FOR ENCLOSED STAIRS. THIS | | PROJECTION SHALL EXTEND VERTICALLY FROM | | THE GROUND TO A POINT 10 FT. ABOVE THE | | TOPMOST LANDING OR THE ROOF LINE, | | WHICH-EVER IS LOWER AND HORIZONTALLY 10 | | FT. | | FROM EACH SIDE OF THE STAIRWAY. | | OPENINGSWITHIN THE 10 FT. HORIZONTAL | | EXTENSION | | OF THE PROTECTED WALLS BEYOND THE | | STAIRWAY SHALL BE EQUIPPED WITH FIXED | | 3/4- HOUR ASSEMBLIES. | | (97 SBC SEC. 1006.2.4) THE NEW WINDOWS | | AND DOORS AT STAIRS MUST COMPLY. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)659-8096 EXT.8202 | 2001-10-30 00:00:00 | ************BUILDING PROVISO************ | | | | 1) PROVIDE MANUFACTURES SPECIFICATIONS, | | UL LISTING INFORMATION, STRUCTURAL | | DRAWINGS AND ELEVATION DRAWINGS FOR | | VENTLESS FIRE BOX PRIOR TO INSTALLATION. | | INSTALLATION MUST COMPLY WITH CHAPTER 9 | | OF THE 97 STANDARD MECHICAL CODE. | | A SEPARATE GAS PERMIT WILL BE REQUIRED | | IF USING A GAS APPLIANCE IN FIRE BOX. | | | | 2) PROVIDE PRODUCT APPROVALS FOR DOUBLE | | INSWING ENTRY DOORS WITH SIDELITES, | | PRIOR TO INSTALLATION. UNIT MUST COMPLY | | WITH LARGE MISSLE IMPACT PROTECTION | | REQUIREMENTS. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)659-8096 EXT.8202 | | | | REVISION WAS RESUBMITTED ON 11-8-01 FOR | | PLBG. AND ELEC. THE ITEMS REQUESTED IN | | ABOVE PROVISO WERE ADDRESSED. | | RM 11-15-01 |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
P |
Date |
2001-03-19 |
|
|
Cont ID |
|
Sent By |
fknapp |
Date |
2001-03-19 |
Time |
14:37 |
Rev Time |
4.00 |
Received By |
fknapp |
Date |
2001-03-19 |
Time |
14:37 |
Sent To |
|
|
Notes |
2001-03-19 00:00:00 | | | | | ************BUILDING PROVISO************ | | | | SBC 104.2.2 | | | | 1) PROVIDE 2 CURRENT COMPLETE COPIES OF | | SBCCI OR METRO DADE PRODUCT APPROVALS | | FOR: | | SLIDING GLASS DOORS | | CIRCLE TOP WINDOWS | | | | ANY QUESTIONS PLEASE CALL, | | FRANK KNAPP | | BUILDING PLAN REVIEW | | DEPARTMENT OF CONSTRUCTION SERVICES | | CITY OF WEST PALM BEACH | | (561) 659-8096 EXT. 8392 |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2001-02-27 |
|
|
Cont ID |
|
Sent By |
fknapp |
Date |
2001-02-27 |
Time |
08:44 |
Rev Time |
5.00 |
Received By |
fknapp |
Date |
2001-02-27 |
Time |
08:43 |
Sent To |
|
|
Notes |
2001-02-27 00:00:00 | | | *************BUILDING UNSAT************* | | | | SBC 104.2.2 | | | | 1) PROVIDE PLANS THAT HAVE RAISED SEAL | | AND ORIGINAL SIGNATURE OF DESIGNER OF | | RECORD. | | | | 2) PROVIDE STORM PANEL INFORMATION WITH | | INSTALLATION SCHEDULE AND KEY PLAN WITH | | SPECIFIC ANCHORS AND MOUNTING TO BE USED | | FOR ALL NON-IMPACT GLAZING. | | | | 3) PROVIDE SOIL TEST PER SEC. 1804.2.2 | | OF CITY AMENDMENTS TO 1997 SBC. | | | | 4) PROVIDE 2 CURRENT COMPLETE COPIES OF | | SBCCI OR METRO DADE PRODUCT APPROVALS | | FOR: | | FRONT INSWING ENTRY DOOR W/ SIDELITE | | SLIDING GLASS DOORS | | SH WINDOWS | | CIRCLE TOP WINDOWS | | | | 5) PROVIDE FLOOD ZONE ELEVATION | | CERTIFICATE FOR NEW CONSTRUTION WITH BFE | | | | 6) PROVIDE NOC RECORDED WITH THE CLERK | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | 7) STRUCTUAL NOTES, LATERAL LOADS REF.94 | | SBC ON SHT A3 94 SBC IS NOT CURRENT. | | | | 8) EGRESS NOTE ON SHT A4 REF. NET CLEAR | | OPENING OF NOT LESS THAN 4 SQUARE FEET, | | EGRESS WINDOWS MUST BE GREATER THAN 4 | | SQUARE FEET. | | | | 9) STAIR DETAIL ON SHT A10 REF. 94 SBC, | | 94 SBC US NOT CURRENT, STAIRS MUST | | COMPLY WITH 97 SBC 1006, 1007 AND 1015. | | PICKETS MUST BE SPACE SO THAT A 4" | | SPHERE CANNOT PAST THROUGH ANY OPENING. | | | | 10) PROVIDE COMPLETE LINTEL TBL. ON SHT. | | A12 | | | | 11) IDENTIFY LOCATION OF CONNECTORS | | FROM CONNECTOR SCHEDULE TO BE USED ON | | SHT. A12 & A13 FRAMING PLANS. | | | | 12) BEFORE A PERMIT TO CONSTRUCT CAN BE | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | BEACH CO.,THE PERMIT PLANS STAMPED BY | | THEM AND THE RECEIPT ATTACHED TO THE | | PERMIT APPLICATION. | | | | ANY QUESTIONS PLEASE CALL, | | FRANK KNAPP | | BUILDING PLAN REVIEW | | DEPARTMENT OF CONSTRUCTION SERVICES | | CITY OF WEST PALM BEACH | | (561) 659-8096 EXT. 8392 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2001-10-22 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2001-10-22 |
Time |
12:18 |
Rev Time |
0.25 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2001-01-23 |
|
|
Cont ID |
|
Sent By |
sgraham |
Date |
2001-01-23 |
Time |
13:31 |
Rev Time |
0.25 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|