Plan Review Details - Permit 00110764
Plan Review Stops For Permit 00110764
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2001-04-12 Cont ID  
Sent By dpalmer Date 2001-04-12 Time 15:07 Rev Time 0.00
Received By dpalmer Date 2001-04-12 Time 15:06 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2000-12-07 Cont ID  
Sent By dpalmer Date 2000-12-07 Time 19:38 Rev Time 0.00
Received By dpalmer Date 2000-12-07 Time 19:38 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-06-08 Cont ID  
Sent By pkrauss Date 2001-06-08 Time 11:23 Rev Time 0.30
Received By pkrauss Date 2001-06-08 Time 11:22 Sent To  
Notes
2001-06-08 00:00:00SUBMITTAL OF ENERGY CALCS.6/8/01 PHK

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2000-12-02 Cont ID  
Sent By jleech Date 2000-12-02 Time 12:04 Rev Time 0.25
Received By jleech Date 2000-12-02 Time 12:04 Sent To  
Notes
2001-01-08 00:00:00PROVISO; ENERGY CAULKS DIF. THAN DRAWING

Review Stop P PLUMBING
Rev No 1 Status P Date 2000-12-02 Cont ID  
Sent By jleech Date 2000-12-02 Time 12:05 Rev Time 0.25
Received By jleech Date 2000-12-02 Time 12:05 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2001-01-09 Cont ID  
Sent By rmcdouga Date 2001-01-09 Time 10:16 Rev Time 2.00
Received By rmcdouga Date 2001-01-09 Time 10:15 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2000-12-22 Cont ID  
Sent By rmcdouga Date 2000-12-22 Time 11:23 Rev Time 2.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-01-08 00:00:00DENIED
  
 1)BUILDING OFFICIAL WILL NOT ACCEPT ROOM
 LABELED DEN/STUDY AS SHOWN WITHOUT
 EXTERIOR EMERGENCY ESCAPE AND RESCUE
 OPENING AS REQUIRED BY 97 SBC 1005.4.
  
 2)PROVIDE INSTALLATION SCHEDULE FOR
 STORM PANELS.
  
 3)SUBMIT 2 REVISED COPIES OF KEY PLAN
 FOR THIS UNIT. THE KEY PLAN SUBMITTED
 SHOWS WINDOWS IN THE 2 HOUR WALL AND
 DOES NOT MATCH THE FOOTPRINT OF THE
 BUILDING.
  
 4)PROVIDE PRODUCT APPROVALS FOR WINDOW
 MULLIONS.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2000-12-12 Cont ID  
Sent By rmcdouga Date 2000-12-12 Time 07:44 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-01-08 00:00:00DENIED
  
 1)IMPACT FEES MUST BE PAID TO PALM BEACH
 COUNTY,PLANS STAMPED BY THEM AND RECEIPT
 SUBMITTED TO CITY OF W.P.B. BUILDING
 DEPT. BEFORE A PERMIT CAN BE ISSUED.
  
 2)UNLABELED ROOM ADJACENT TO LIVING ROOM
 MUST COMPLY WITH SECTION 1203 OF THE
 1997 STANDARD BUILDING CODE FOR LIGHT
 AND VETILATION.
 SECTION 1203.1.5 ALLOWS WINDOWS TO BE
 OMITTED IN HABITABLE ROOMS IF ADEQUATE
 ADEQUATE LIGHT AND VENTILATION ARE
 PROVIDED THROUGH OTHER SOURCES APPROVED
 BY THE BUILDING OFFICIAL.
 PLEASE PROVIDE SPECIFIC DETAILS AS TO
 WHICH METHODS WILL BE USED TO MEET THESE
 REQUIREMENTS.
  
 3)THE UNLABELED ROOM MUST HAVE AT LEAST
 ONE EXTERIOR EMERGENCY ESCAPE AND RESCUE
 OPENING,IF IT IS USED AS A SLEEPING ROOM
 PER 1005.4.1 OF 97 SBC (SEE EXCEPTIONS).
 ALTHOUGH THERE IS NO CLOSET IN THIS ROOM
 IT COULD BE USED AS A BEDROOM. BEDROOM
 #2 SHOWN ON THE PLANS ALSO HAS NO CLOSET
  
 4)PROVIDE INSTALLATION SCHEDULE FOR
 STORM PANELS.
  
 5)THE KEY PLAN PROVIDED DOES NOT COMPLY
 WITH THE ARCHITECTURAL DRAWINGS. PLEASE
 SUBMIT (2) COPIES OF REVISED KEY PLAN.
  
 6)PROVIDE 2 CURRENT COPIES OF METRO-DADE
 OR SBCCI PRODUCT APPROVALS FOR THE
 FOLLOWING ITEMS:
 -SLIDING GLASS DOORS
 -MULLIONS
  
 7)PROVIDE PRODUCT APPROVALS FOR ROOF
 COVERING UNDER SEPARATE PERMIT.

Review Stop Z ZONING
Rev No 1 Status P Date 2000-12-12 Cont ID  
Sent By rmcdouga Date 2000-12-12 Time 07:42 Rev Time 0.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-01-08 00:00:00OK PER SHIRLEY GRAHAM 11-27-00 RLM