|
 |
 |
 |
 |
 |
Plan Review Details - Permit 00110332
Plan Review Stops For Permit 00110332 |
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2000-12-27 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2000-12-27 |
Time |
14:13 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2000-12-27 |
Time |
14:13 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | APPROVED PROVISO: SEPARATE PLANS AND | | PERMITS REQUIRED FOR GAS AND ELECTRIC | | WORK. | | | | CAPTAIN MIKE CARSILLO | | 659-8096,EXT.8497 | | 835-2910 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2000-12-11 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2000-12-11 |
Time |
15:18 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2000-12-11 |
Time |
15:18 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | ON DECEMBER 11, 2000, WRITER ALONG WITH | | PLUMBING PLAN REVIEWER JOHN LEECH | | EXAMINED THE INFORMATION FOR PERMIT | | 00110332. SEVERAL CONCERNS WERE RAISED | | BY JOHN LEECH AND THIS WRITER. ON SAME | | DATE, WRITER CONTACTED MARK KAPLAN OF | | BRADLEY HEATING AND A/C, INC. | | ACCORDING TO MR. KAPLAN THE PROPANE | | TANKS ARE APPROXIMATELY 25 FEET FROM | | OTHER BUILDINGS. THIS INFORMATION IS | | NOT SHOWN ON THE DRAWINGS. HE ALSO | | ADVISED THAT THE PROPANE TANKS ARE | | APPROXIMATELY 25 FEET FROM PROPERTY | | LINES. HE FURTHER ADVISED THAT GAS | | PIPING WILL BE DONE BY OTHERS. HE | | ALSO ADVISED THAT HE BELIEVES THAT | | THIS PIPING WILL BE 1/2 INCH GALVANIZED | | OR BLACK AND WOULD PROBABLY BE CLAMPED | | OR UNISTRUTED TO THE BUILDING.HE ALSO | | STATED THAT NO DOORS ARE PRESENT ALONG | | THE SIDE OF THE BUILDING NEAR THE | | PROPANE STORAGE. | | 1) NO SMOKING SIGNS ARE TO BE PROVIDED. | | 2) COMPLIANCE WITH NFPA 704 IS | | REQUIRED. | | 3) COMPLIANCE WITH NFPA 58 IS REQUIRED. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2000-12-27 |
|
|
Cont ID |
|
Sent By |
ndenmark |
Date |
2000-12-27 |
Time |
15:05 |
Rev Time |
0.50 |
Received By |
ndenmark |
Date |
2000-12-27 |
Time |
15:05 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | PROVISO: | | 1. ELECTRICAL PERMIT REQUIRED FOR ALL | | ELECTRICAL WORK RELATED TO THIS PERMIT | | ELECTRICAL CONTRACTOR TO PROVIDE INFO ON | | GENERATOR ALONG W/ WIRING INFO AT TIME | | OF PERMIT APPLICATION FOR ELECTRIC WORK | | 2. GAS PERMIT REQUIRED FOR GAS CONNECT- | | ED TO THIS PROJECT. CONTRACTOR TO PROVID | | INFORMATION ON PIPING, TANK AND CODE | | COMPLIANCE AS REQUIRED BY ATTACHED FIRE | | REVIEW COMMENTS |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |