Plan Review Details - Permit 00101227
Plan Review Stops For Permit 00101227
Review Stop E ELECTRICAL
Rev No 4 Status P Date 2001-12-18 Cont ID  
Sent By dpalmer Date 2001-12-18 Time 07:40 Rev Time 0.00
Received By dpalmer Date 2001-12-18 Time 07:40 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2000-12-18 Cont ID  
Sent By dpalmer Date 2000-12-18 Time 13:03 Rev Time 0.00
Received By dpalmer Date 2000-12-18 Time 13:03 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2000-11-30 Cont ID  
Sent By dpalmer Date 2000-11-30 Time 20:55 Rev Time 0.00
Received By dpalmer Date 2000-11-30 Time 20:55 Sent To  
Notes
2001-01-08 00:00:00************** UNSAT ******************
  
 1)NOTE: AS ASKED FOR AND REQ`D FROM
 FIRST REVIEW. PLEASE SUBMIT AIC RATING
 FOR MAIN AND PANELS. PER 110-9/215-5
  
 2)NOTE: PLEASE NOTE ALL OUTLETS SERVING
 KITCHEN COUNTERSPACE ARE TO BE GFI/GFI
 PROTECTED PER 210-8-A-6 PLEASE SHOW
  
 3)NOTE: PLEASE SEE MISSING SD LOWER
 LEVEL.
  
 4)NOTE: PLEASE NOTE THAT THE PLANS ARE
 NOW SHOWING COMPLETE REWIRE? IF CATV
 AND TELEPHONES ARE GOING TO BE INSTALLED
 THEN THEY MUST BE ON PLAN???
  
 5)NOTE: PLEASE NOTE THAT NO PANEL SCHED-
 -ULE WAS SUBMITTED AND MISSING BATH(S)
 CIRCUIT(S) PER 210-11-C-3. AS ASKED FOR
 ON PREVIOUS REVIEW.
  
 6)NOTE: PLEASE SEE LOAD CALCULATIONS?
 YOU SHOW TWO SEPARATE A/C UNITS? PLEASE
 SHOW THESE ON PLANS AND SHOW DISCONNECTS
 PER 440-11 AND GFI PER MECH CODE 309.1
 PLEASE SHOW IN HOUSE AHU`S.
 AS ON PREVIOUS NOTE IF THERE ARE EXIST-
 -ING ELECTRICAL CONDITIONS?? PLEASE SHOW
 AND PROVIDE CLARIFICATION.
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2000-11-03 Cont ID  
Sent By dpalmer Date 2000-11-03 Time 10:33 Rev Time 0.00
Received By dpalmer Date 2000-11-03 Time 10:33 Sent To  
Notes
2001-01-08 00:00:00************** UNSAT *******************
  
 1)NOTE: NO ELECTRICAL WAS SUBMITTED FOR
 NEW ADDITION AREA. PLEASE SUBMIT.
  
 2)NOTE: THE ELECTRICAL THAT WAS SUBMIT-
 -TED FOR SECOND FLOOR IS FOR WHAT? IS
 THIS AREA BEING REWIRED? IF SO PLEASE
 MAKE NOTE ON PLANS FOR CLARIFICATION.
  
 3)NOTE: ALSO PLEASE NOTE THAT A SD WILL
 BE REQ`D ON THE FIRST LEVEL AT THE BOT-
 -TOMOF THE STAIRS,,, NFPA-72
  
 4)NOTE: PLEASE SUBMIT AIC RATING FOR
 ALL EQUIPMENT BEING INSTALLED. PER 110-9
 AND 215-5
  
 5)NOTE: PLEASE LIST THE REQ`D BATH(S)
 CIRCUIT(S) ON PANEL SCHEDULE PER 210-52D
 AND 210-11-C-3
  
 6)NOTE: PLEASE NOTE THAT IF THERE IS
 GOING TO BE ANY CATV OR TELEPHONES
 UPSTAIRS THEN PLEASE DRAW ON PLAN. IF
 THEY ARE EXISTING THEN DISREGUARD.
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION
 FOR REVIEW. IF THERE ARE ANY QUESTIONS
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2000-11-04 Cont ID  
Sent By jleech Date 2000-11-04 Time 07:29 Rev Time 0.25
Received By jleech Date 2000-11-04 Time 07:29 Sent To  
Notes
2001-01-08 00:00:00NO A/C PLAN;
 A/C CONTRACTOR TO PROVIDE A/C PLAN WITH
 PERMIT APPLICATION.

Review Stop P PLUMBING
Rev No 2 Status P Date 2000-12-05 Cont ID  
Sent By lmartine Date 2000-12-05 Time 11:11 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
2001-01-08 00:00:00SEE APPROVAL BY JOHN LEECH ON BACK OF
 APPLICATION.
 L.MARTINEZ 12/5/00

Review Stop P PLUMBING
Rev No 1 Status F Date 2000-10-29 Cont ID  
Sent By tlarge Date 2000-10-29 Time 08:58 Rev Time 0.33
Received By tlarge Date 2000-10-29 Time 08:58 Sent To  
Notes
2001-01-08 00:00:001)SUBMIT SANITARY AND WATER RISER
 DIAGRAMS FOR REVIEW THAT REFLECT ENTIRE
 SCOPE OF WORK TO BE PERFORMED.
  
 CALL IF YOU HAVE QUESTIONS.
 5610659-8096,EXT.8377.
  
 TIMOTHY LARGE
 PLUMBING PLANS EXAMINER.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2000-12-05 Cont ID  
Sent By lmartine Date 2000-12-05 Time 18:39 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2000-11-07 Cont ID  
Sent By lmartine Date 2000-11-07 Time 12:03 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
2001-01-08 00:00:00BUILDING COMMENTS
 -------------------
  
 1]
 NEW 8"CMU FENCE WILL NOT BE PART OF THIS
 PERMIT.
  
 2]
 APPLICATION CALLS FOR CHANGING INTERIOR
 DOORS,PLAN SHOWS NEW EXTERIOR DOORS,
 GARAGE AND FRENCH,TEST REPORTS ARE
 REQUIRED FOR EXTERIOR DOORS,WINDOWS
 AND ROOF COVERS,ALL NEW GLAZING SHALL
 BE IMPACT PROTECTED.
  
 3]
 PROVIDE FOUNDATION PLAN,WALL SECTIONS
 SHALL INCLUDE ALL VERTICAL REINFORCEMENT
 CONTIUOUS THRU TIE BEAM,BE SPECIFIC WITH
 THE CONNECTION OF ROOF SYSTEM AND WALLS.
  
 4]
 SUPPLY DETAIL FOR BRACKET BEAM AND OVER-
 HANG AT GARAGE.
  
 5]
 PROVIDE DETAIL FOR NEW PARAPET AT GARAGE
  
 6]
 SUBMIT INTERIOR WALL SECTIONS,WILL ANY
 INSULATION BE APPLIED?
  
 7]
 A RECORDED NOTICE OF COMMENCEMENT SHALL
 BE SUBMITTED BEFORE PERMIT ISSUANCE.
  
  
  
 REVIEWED BY:
 LUIS MARTINEZ
 659-8096
 EXT. 8456

Review Stop Z ZONING
Rev No 1 Status P Date 2000-11-03 Cont ID  
Sent By sgraham Date 2000-11-03 Time 11:00 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***