Plan Review Details - Permit 00100763
Plan Review Stops For Permit 00100763
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2000-11-21 Cont ID  
Sent By lmartine Date 2000-11-21 Time 15:15 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2000-11-09 Cont ID  
Sent By dpalmer Date 2000-11-09 Time 15:14 Rev Time 0.00
Received By dpalmer Date 2000-11-09 Time 15:14 Sent To  
Notes
2001-01-08 00:00:00**************** NOTE *****************
  
 1)NOTE: PLEASE REVISE PLAN AND INCLUDE
 ALL BRANCH CIRCUIT #`S SHOWN ON PLAN,
 PLEASE CORRELATE WITH PANEL SCHEDULE.
 ALSO PLEASE NOTE THE AMOUNT OF DEVICES
 ON EACH CIRCUIT>
  
 PLEASE SUBMIT THE ABOVE INFORMATION
 FOR REVIEW BEFORE FINAL.
 IF THERE ARE ANY QUESTIONS PLEASE CALL
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2000-10-19 Cont ID  
Sent By dpalmer Date 2000-10-19 Time 21:01 Rev Time 0.00
Received By dpalmer Date 2000-10-19 Time 21:01 Sent To  
Notes
2001-01-08 00:00:00*************** UNSAT *****************
  
 1)NOTE: PLEASE SUBMIT INFORMATION ON NEW
 100AMP PANEL SHOWN ON PLANS????
 FOR WHAT? FROM WHERE? LOADS, WIRE, ETC
 NO INFORMATION SUBMITTED FOR NEW PANEL;
 PANEL SCHEDULE FOR LOADS,AND LOAD
 CALCULATION FOR PANEL AND HOW ITS BEING
 FED.ETC
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW.IF THERE ARE ANY QUESTIONS PLEASE
 CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2000-11-21 Cont ID  
Sent By lmartine Date 2000-11-21 Time 15:50 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
2001-01-08 00:00:00OK TO APPROVE PER MIKE,
 PERMIT IS FOR SEPERATION WALL ONLYLM

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2000-11-21 Cont ID  
Sent By mcarsill Date 2000-11-21 Time 12:58 Rev Time 0.00
Received By mcarsill Date 2000-11-21 Time 12:52 Sent To  
Notes
2001-01-08 00:00:001) PLANS DO NOT INDICATE LOCATIONS OF
 REQUIRED EMERGENCY LIGHTS OR ILLUMINATED
 EXIT SIGNS.
 2) DOOR 4 DOES NOT PROVIDE PROPER EXIT
 WIDTH TO EXIT DOOR.
 3) NO INTERIOR FINISH INFORMATION NOTED
 ON PLANS.
 4) SEATING DIAGRAM NOT PROVIDED WITH
 PLANS TO DETERMINE OCCUPANT LOAD OR
 EXIT CAPACITIES.
 5) A SINGLE STEP TO COUNTER BAR AREA IS
 NOT PERMITTED. CHANGES IN ELEVATION
 LESS THAN 21 INCHES SHALL BE BY RAMPS.
 STEPS WHEN USED ARE TO TOTAL THREE AT
 7 INCHES EACH.
 6) PROVISIONS ARE TO BE MADE FOR AT
 TWO HANDICAPPED PERSONS.
 7) IF OCCUPANT LOAD IS TO BE DETERMINED
 AT 100 OR MORE PERSONS, PANIC HARDWARE
 IS REQUIRED ON ALL EXIT DOORS.
  
 CAPTAIN MIKE CARSILLO
 659-8096,EXT.8497
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2000-10-30 Cont ID  
Sent By mcarsill Date 2000-10-30 Time 10:13 Rev Time 0.00
Received By mcarsill Date 2000-10-30 Time 10:13 Sent To  
Notes
2001-01-08 00:00:001) A C LABEL (45) MINUTE FIRE DOOR
 WITH CLOSER IS TO BE INSTALLED IN FIRE
 RATED WALL OPENING THAT IS BEING
 CONSTRUCTED.
 2) PLEASE EXPLAIN THE TWO EXIT SIGNS
 PLANNED FOR BOTH SIDES OF THE WALL.
 3) WHAT IS THE OTHER TENANT SPACE THAT
 IS NOT MARKED DINING ROOM.
  
 PLANS REVIEWED BY CAPTAIN MIKE CARSILLO
 659-8096,EXT.8497
 835-2910