Plan Review Details - Permit 00091222
Plan Review Stops For Permit 00091222
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2000-10-25 Cont ID  
Sent By drunnels Date 2000-10-25 Time 09:33 Rev Time 1.50
Received By drunnels Date 2000-10-25 Time 09:33 Sent To  
Notes
2001-01-08 00:00:00PROVISO
 1.DOOR #12 SHALL COMPLY WITH SECTION
 1012.1.5 1997 SBC

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2000-10-25 Cont ID  
Sent By dpalmer Date 2000-10-25 Time 01:22 Rev Time 0.00
Received By dpalmer Date 2000-10-25 Time 01:22 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2000-11-14 Cont ID  
Sent By mcarsill Date 2000-11-14 Time 08:27 Rev Time 0.00
Received By mcarsill Date 2000-11-14 Time 08:27 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2000-11-02 Cont ID  
Sent By mcarsill Date 2000-11-02 Time 17:44 Rev Time 0.00
Received By mcarsill Date 2000-11-02 Time 17:44 Sent To  
Notes
2001-01-08 00:00:001) NO HYDRAULIC CALCULATIONS PROVIDED
 WITH FIRE SPRINKLER PLANS.
 2) A FOLDED SET OF E2.1 PLANS HAS BEEN
 AMENDED BUT ARE NOT SIGNED AND SEALED
 LIKE THE PLANS. THE E2.1 PLANS DO NOT
 CORRELATE. ORIGINAL E2.1 MUST BE
 REVISED. PLEASE REFER TO FS 61G15-23.002
 471.025
 3) NO INTERIOR FINISH INFORMATION
 PROVIDED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2000-09-29 Cont ID  
Sent By mcarsill Date 2000-09-29 Time 15:40 Rev Time 0.00
Received By mcarsill Date 2000-09-29 Time 15:39 Sent To  
Notes
2001-01-08 00:00:001) FIRE SPRINKLER DRAWINGS AND HYDRAULIC
 CALCULATIONS ARE TO BE PROVIDED WITH
 PLANS. ACCORDING TO THE PLANS THE FIRE
 SPRINKLERS WILL BE PERMITTED SEPARATELY
 NO BUILDING PERMIT WILL BE ISSUED
 WITHOUT SPRINKLER DRAWINGS.
 2) DOORS 01 AND 12 ARE TO BE EQUIPPED
 WITH SELF-CLOSING DEVICES. WHEN CLOSED
 THESE DOORS ARE REQUIRED TO POSITIVELY
 LATCH
 3) PLEASE INDICATE INTERIOR FINISHES
 FOR EXITS AND OFFICES. THE CURRENT FIRE
 CODE REQUIRES THAT INTERIOR FINISHES
 IN EXITS BE CLASS A OR B. INTERIOR
 FINISHES IN OFFICES CAN BE CLASS A,B,
 OR C.
 4) THE FIRE ALARM NOTES SECTION OF THE
 PLAN INDICATES CLASS B, STYLE C
 CIRCUITS. ONLY CLASS A, STYLE D FIRE
 ALARM CIRCUITS ARE PERMITTED.
 5) PLEASE SUBMIT FIRE ALARM SYSTEM
 SHOP DRAWINGS FOR NEW FIRE ALARM
 EQUIPMENT SHOWN ON PLANS. CUT SHEETS
 ARE TO BE PROVIDED WITH FIRE ALARM
 PLANS.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2000-10-21 Cont ID  
Sent By ndenmark Date 2000-10-21 Time 09:36 Rev Time 0.33
Received By ndenmark Date 2000-10-21 Time 09:36 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2000-12-04 Cont ID  
Sent By jleech Date 2000-12-04 Time 07:17 Rev Time 0.33
Received By jleech Date 2000-12-04 Time 07:17 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2000-09-30 Cont ID  
Sent By tlarge Date 2000-09-30 Time 07:03 Rev Time 0.50
Received By tlarge Date 2000-09-30 Time 06:52 Sent To  
Notes
2001-01-08 00:00:00*****************PROVISO****************
 LOUNGE SINK AND CABINET SHALL COMPLY W/
 FACBC SEC.4.24.1.-4.24.7.
  
 CALL 561-659-8096,EXT.8377 IF YOU HAVE
 ANY QUESTIONS.
 TIMOTHY LARGE
 PLUMBING PLANS EXAMINER.