Plan Review Stops For Permit 00090107 |
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2001-12-18 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-12-18 |
Time |
08:59 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-12-18 |
Time |
08:59 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2001-11-13 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-11-13 |
Time |
10:54 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2001-11-13 |
Time |
13:45 |
Sent To |
P |
|
Notes |
2001-11-13 00:00:00 | ******************* UNSAT ************ | | | | 1)NOTE: PLEASE NOTE THAT THE PLANS | | SUBMITTED FOR GUEST/GARAGE DO NOT | | CORRELATE WITH PLANS FORMAIN HOUSE | | SERVICE. TWO PLANS /TWO SERVICES? | | | | 2)NOTE: PLEASE CLARFIY SIZE OF METERCAN, | | SHOWN AS EXISTING? LOAD SHOWN AT 269.9A | | | | 3)NOTE: PLEASE NOTE THAT ON GUEST HOUSE | | METER AND TWO DISCONNECTS ARE SHOWN, BUT | | DOES NOT SHOW WHERE PANEL IS ON PLANS? | | NOTE NEXT TO SERVICE SAYS, "GUEST HOUSE | | PANEL" , THEN WHERE IS MAIN DISCONNECT | | SHOWN ON RISER DIAGRAM? | | | | 4)NOTE: PLEASE NOTE MISSING GROUNDING | | AT DETACHED MAIN HOUSE. 250-32. | | | | 5)NOTE: PLEASE INDICATE MCB FOR PANEL | | AT MAIN HOUSE DETACHED FROM GUEST HOUSE | | SERVICE. 225-31 | | | | 6)NOTE: PLEASE NOTE MISSING EQUIPMENT | | GROUNDING CONDUCTORS BETWEEN MAIN DISC`S | | AND PANELS. 250-122 | | | | 7)NOTE: PLEASE CLARIFY 2/0`S SHOWN FOR | | 100A EQUIPMENT? | | | | 8) NOTE: PLEASE LIST THE REQ`D BATH(S) | | CIRCUIT(S) PER 210-11-C-3. | | MUST BE 20A AND #12AWG. | | ARE THE GFI CIRCUITS THAT ARE SHOWN ON | | PANEL SCHEDULE FOR THIS? | | | | 9)NOTE: PLEASE SHOW GARAGE ON THE | | ELECTRICAL PLAN AND SHOW REQ`D ELEC. | | FOR GARAGE. PLAN SHOW GARAGE AS DETACHED | | ?? PLEASE CLARIFY. | | | | PLEASE MAKE THE ABOVE CORRECTIONS AND | | SUBMIT THE INFORMATION FOR REVIEW. IF | | THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2000-10-19 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2000-10-19 |
Time |
21:46 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2000-10-19 |
Time |
21:46 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | **************** UNSAT **************** | | | | 1)NOTE: PLEASE CLARIFY PLANS, YOU SHOW | | GARAGE AS FUTURE BUT ARE SHOWING AS NEW | | ROOF ETC??? ELECTRIC REQ`D IF NEW? | | | | 2)NOTE: PLEASE SHOW NEW CU FOR A/C | | DISCONNECT PER 440-11 AND WP GFI. | | | | 3)NOTE: PLEASE NOTE PER FIRST REVIEW, | | MISSING GFI FOR REAR OF BLDG. 210-52E | | | | 4)NOTE: PLEASE SHOW WINDOW A/C BEING TAK | | -EN OUT? IS A/C ON FIRST FLOOR FEEDING | | SECONG FLOOR? | | | | 5)NOTE: LOAD CALCULATIONS (SQ FT) DOES- | | -NOT MATCHFLOOR SQ FT.?? IS FIRST | | FLOOR AND SECOND FLOOR ON SAME PANEL? | | | | 6)NOTE: SINCE FIRST REVIEW A NEW SERVICE | | IS BEING SHOWN.. 100AMP PANEL W/ 2/0 | | WIRE? IS THIS CORRECT? | | PLEASE SUBMIT AIC RATING OF NEW MAIN | | DISCONNECT AND PANEL. MUST BE RATED FOR | | AVAILABLE FAULT CURRENT PER 110-9 AND | | 215-5. | | | | 7)NOTE: PLEASE SHOW BATH(S) CIRCUIT(S) | | REQ`D PER 210-11-C-3 AND 210-52D. #12 AN | | 20AMP. | | | | 8)NOTE: PLEASE NOTE;YOU SHOW DISCONNECTS | | ON AHU AND WATER HEATER? NOTE 110-26 FOR | | DISC CLEARENCE. PANEL IS WITHIN SIGHT | | ACCROSS HALL?S | | | | 9)NOTE: PLEASE CHECK LOAD SHOWN FOR | | WATER HEATER ON #12 AND 20AMP BRKR? | | PLEASE NOTE THAT OCP FOR A 4500W WATER | | HEATER MUST BE 125%. 4500W EXCEEDS 80% | | OF BRKR. | | | | 10)NOTE: PLEASE SEE 250-122 AND SIZE | | EQUIPMENT GROUNDING CONDUCTOR FROM | | MAIN TO PANEL. | | | | 1)NOTE: PLEASE SHOW EGRESS LIGHTING FOR | | MAIN GUEST ROOM FIRST FLOOR. PER 210-70 | | | | PLEASE SUBMIT ALL THE ABOVE INFORMATION | | FOR REVIEW. IF THERE ARE ANY QUESTIONS | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW. | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2000-09-11 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2000-09-11 |
Time |
17:15 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2000-09-11 |
Time |
17:14 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | *************** UNSAT ***************** | | | | 1)NOTE: PLEASE SUBMIT PANEL SCHEDULE | | AND LOAD CALCULATIONS FOR NEW REMODELED | | AREA.215-5 | | THERE APPEARS TO BE TWO SEPARATE APART- | | -MENTS? HOW ARE THEY BEING FED? IS THERE | | SEPARATE PANELS FOR EACH FLOOR? | | PLEASE SHOW CLARIFICATION.MEANS OF DISC? | | | | 2)NOTE: ALSO MORE THAN 50% OF THIS STRUC | | -TURE IS BEING REMODELED.? | | PLEASE INSTALL SMOKE DETECTOR ON 2ND | | FLOOR.WIRE INLINE | | | | 3)NOTE: PLEASE ADD GFI OUTLETS PER 210- | | -52-E. | | | | 4)NOTE: PLEASE SEE 210-52D AND 210-11-C- | | -3 FOR REQ`D BATH(S) CIRCUIT(S). MUST BE | | #12 AND 20AMP. | | | | | | PLEASE SUBMIT ALL THE ABOVE INFORMATION | | FOR REVIEW. IF THERE ARE ANY QUESTIONS | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW. | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2000-11-21 |
|
|
Cont ID |
|
Sent By |
fknapp |
Date |
2000-11-21 |
Time |
10:35 |
Rev Time |
0.00 |
Received By |
fknapp |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2001-11-14 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2001-11-13 |
Time |
19:37 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2001-11-13 |
Time |
19:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2000-09-10 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2001-11-13 |
Time |
14:06 |
Rev Time |
0.30 |
Received By |
tlarge |
Date |
2000-09-10 |
Time |
08:42 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | *****************PROVISO**************** | | SUBMIT SANITARY AND WATER RISER DIAGRAMS | | PRIOR TO PLUMBING INSPECTION. | | | | CALL 561-659-8096,EXT.8377 IF YOU HAVE | | ANY QUESTIONS. | | TIMOTHY LARGE | | PLUMBING PLANS EXAMINER. |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
3 |
Status |
P |
Date |
2001-12-18 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2001-12-18 |
Time |
18:34 |
Rev Time |
2.00 |
Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-12-18 00:00:00 | ************BUILDING PROVISO************ | | | | 1)PROVIDE (2) CURRENT AND COMPLETE | | COPIES OF SBCCI OR METRO-DADE PRODUCT | | APPROVALS FOR: | | - CASEMENT WINDOWS | | - EXTERIOR DOORS | | | | 2) PROVIDE KEY PLAN AND INSTALLATION | | SCHEDULE FOR STORM PANELS PRIOR TO | | INSTALLATION. |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
F |
Date |
2001-11-15 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2001-11-15 |
Time |
13:09 |
Rev Time |
2.00 |
Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-11-16 00:00:00 | REVISION DENIED | | | | 1) PROVIDE AN EMERGENCY ESCAPE AND | | RESCUE OPENING FOR THE SECOND FLOOR | | GUEST ROOM PER 97 SBC SEC. 1005.4.1. | | THE WINDOW MUST HAVE A MINIMUM NET CLEAR | | OPENING OF 5.7 SQ.FT. WITH A MINIMUM NET | | CLEAR OPENING HEIGHT OF 24" AND MINIMUM | | NET CLEAR OPENING WIDTH OF 20". THE SILL | | HEIGHT CAN NOT BE MORE THAN 44" PER 97 | | SBC SEC.1005.4.4 AND 1005.4.3. | | | | 2)PROVIDE (2) CURRENT AND COMPLETE | | COPIES OF SBCCI OR METRO-DADE PRODUCT | | APPROVALS FOR: | | - STRUCTURAL WINDOW MULLIONS | | - STORM PANELS OR IMPACT GLASS | | | | 3) PROVIDE ACCESS TO ATTIC SPACE PER | | 97 SBC SEC. 2309.6. | | | | 4) EXTERIOR EXITWAY STAIRS: | | EXTERIOR STAIRS SHALL BE SEPARATED FROM | | THE INTERIOR OF THE BUILDING BY WALLS | | WITH A FIRE RESISTANCE RATING OF NOT | | LESS THAN 1 HOUR, WITH FIXED OR SELF- | | CLOSING OPENING PROTECTIVES AS REQUIRED | | FOR ENCLOSED STAIRS. PROTECTION SHALL | | EXTEND VERTICALLY FROM THE GROUND TO A | | POINT 10 FEET ABOVE THE TOPMOST LANDING | | OR THE ROOF LINE WHICHEVER IS LOWER AND | | HORIZONTALLY 10 FEET FROM EACH SIDE OF | | THE STAIRWAY. OPENINGS WITHIN THE 10 | | FOOT HORIZONTAL EXTENSION OF THE | | PROTECTED WALLS BEYOND THE STAIRWAY | | SHALL BE EQUIPPED WITH FIXED 3/4- HOUR | | ASSEMBLIES. 97 SBC SEC. 1006.2.4 THE NEW | | DOORS AND WINDOWS IN THIS AREA MUST | | COMPLY. SEE 97 SBC SEC. 705.1.3 FOR | | APPROVED TYPES OF FIRE WINDOWS AND DOORS | | | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)659-8096 EXT.8202 |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
P |
Date |
2000-09-27 |
|
|
Cont ID |
|
Sent By |
fknapp |
Date |
2000-09-27 |
Time |
11:06 |
Rev Time |
2.00 |
Received By |
fknapp |
Date |
2000-09-27 |
Time |
11:05 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | | | | | | | ************BUILDING PROVISO************ | | | | SBC 104.2.2 | | | | 1)PROVIDE 2 CURRENT COPIES OF SBCCI OR | | METRO DADE PRODUCT APPROVALS FOR NEW | | EXTERIOR DOORS AND WINDOWS. | | | | 2)PROVIDE OWNER/AGENT SIGNATURE ON | | ENERGY CALCULATIONS. | | | | 3)PROVIDE MECHANICAL DRAWINGS WITH | | MECHANICAL PERMIT APPLICATION. | | | | 4)MUST OBTAIN ZONING APPROVAL. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2000-11-14 |
|
|
Cont ID |
|
Sent By |
gjoyce |
Date |
2000-09-27 |
Time |
09:56 |
Rev Time |
0.10 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | CAN NOT DO 2 KITHCENS!!! |
|
|