Plan Review Details - Permit 00071214
Plan Review Stops For Permit 00071214
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2000-07-31 Cont ID  
Sent By dpalmer Date 2000-07-31 Time 09:02 Rev Time 0.00
Received By dpalmer Date 2000-07-31 Time 09:02 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2000-08-14 Cont ID  
Sent By cthirben Date 2000-08-14 Time 16:02 Rev Time 1.00
Received By cthirben Date 2000-08-14 Time 16:02 Sent To  
Notes
2001-01-08 00:00:00NOTES:
 MECHANICAL PLANS TO BE SUBMITTED BY MECH
 CONTRACTOR FOR REVIEW AS STATED ON PLANS

Review Stop P PLUMBING
Rev No 1 Status P Date 2000-07-28 Cont ID  
Sent By tlarge Date 2000-07-28 Time 07:32 Rev Time 0.30
Received By tlarge Date 2000-07-28 Time 07:32 Sent To  
Notes
2001-01-08 00:00:00SUBMIT SANITARY AND WATER RISER DIAGRAMS
 PRIOR TO PLUMBING INSPECTION.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2000-08-28 Cont ID  
Sent By rmcdouga Date 2000-08-28 Time 14:45 Rev Time 1.00
Received By rmcdouga Date   Time   Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2000-08-11 Cont ID  
Sent By rmcdouga Date 2000-08-11 Time 12:27 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-01-08 00:00:00DENIED
  
 1)IMPACT FEES MUST BE PAID TO PALM BEACH
 COUNTY, PLANS STAMPED BY THEM AND COPY
 OF RECIEPT SUBMITTED TO CITY OF WPB
 BUILDING DEPT. BEFORE A PERMIT CAN BE
 ISSUED.
  
 2)PROVIDE 2 CURRENT COPIES OF METRO-DADE
 OR SBCCI PRODUCT APPROVALS FOR EXTERIOR
 WINDOW SHOWN ON PLANS.
  
 3)MISSLE IMPACT PROTECTION IS REQUIRED
 FOR ALL EXTERIOR GLAZING. CITY AMENDMENT
 TO 97 SBC 1606.4.
  
 4)PROVIDE 2 CURRENT COPIES OF METRO-DADE
 OR SBCCI PRODUCT APPROVALS INDICATING
 SPECIFIC ANCHORS TO BE USED FOR STORM
 PANELS.
  
 5)SAFETY GLASS IS REQUIRED IN BATHROOM
 WINDOW WHERE BOTTOM EDGE OF GLAZING IS
 LESS THAN 60" ABOVE DRAIN INLET. 97 SBC
 2405.2
  
 6)PROVIDE R-11 INSULATION IN FLOOR PER
 1997 FLORIDA ENERGY CODE.
  
 7)R-19 BAT INSULATION WILL NOT FIT IN A
 2X4 WALL AS INDICATED ON PLANS.CLARIFY.
  
 8)PLANS INDICATE U-BLOCK ON TOP OF STEM
 WALL. INDICATE TYPE OF STEEL REINFORCE-
 MENT TO BE USED.
  
 9)PROVIDE FIRE STOPS AT CEILING IN
 BALLOON FRAMED EXTERIOR WALL.97 SBC 2305
  
 10)PROVIDE ACCESS TO ATTIC.97 SBC 2309.6
  
 11)PROVIDE CRAWL SPACE VENTILATION PER
 97 SBC 1804.6.2.1
  
 12)SPECIFY CRAWL SPACE ACCESS OPENING
 SIZE PER 97 SBC 1804.6.2.2
  
 13)CLARIFY CONNECTION OF FLOOR JOISTS TO
 P.T. SILL PLATE.
  
 14)SPECIFY TYPE OF CONNECTORS USED TO
 ANCHOR NEW RAFTERS TO LEDGER ON EXISTING
 ROOF AND RAFTER TO RIDGE CONNECTIONS.
  
 15)CLARIFY ATTACHMENT OF GABLE WALL TO
 ROOF CONNECTIONS.
  
 16)CLARIFY 12" MAXIMUM SPACING OF NAILS
 AT 2X6 LEDGER ON EXISTING ROOF. SHOULD
 IT BE NAILED AT EVERY RAFTER OR TRUSS.

Review Stop Z ZONING
Rev No 1 Status P Date 2000-08-14 Cont ID  
Sent By rmcdouga Date 2000-08-14 Time 15:46 Rev Time 0.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-01-08 00:00:00OK PER ANGELLA JONES 8-14-00 RM