Plan Review Stops For Permit 00071187 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2000-10-24 |
|
|
Cont ID |
|
Sent By |
drunnels |
Date |
2000-10-24 |
Time |
08:40 |
Rev Time |
1.00 |
Received By |
drunnels |
Date |
2000-10-24 |
Time |
08:38 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | REVISION 10/18/2000 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2000-08-28 |
|
|
Cont ID |
|
Sent By |
drunnels |
Date |
2000-08-28 |
Time |
11:36 |
Rev Time |
1.00 |
Received By |
drunnels |
Date |
2000-08-28 |
Time |
11:35 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | HOLD FOR FIRE SPRINKLER PERMIT |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2000-08-25 |
|
|
Cont ID |
|
Sent By |
drunnels |
Date |
2000-08-25 |
Time |
09:23 |
Rev Time |
1.00 |
Received By |
drunnels |
Date |
2000-08-25 |
Time |
09:23 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | **************PROVISO****************** | | 1.STOREFRONT TO BE UNDER SEPERATE PERMIT | | 2.SIGNS TO BE UNDER SEPERATE PERMIT |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2000-08-08 |
|
|
Cont ID |
|
Sent By |
drunnels |
Date |
2000-08-08 |
Time |
11:29 |
Rev Time |
1.00 |
Received By |
drunnels |
Date |
2000-08-08 |
Time |
11:28 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | 1. SUBMIT LETTER FROM SPECIAL CONTRACTOR | | RELEASING SPACE. | | 2. SUBMIT PRODUCT APPROVAL FOR IMPACT | | RESISTANT GLAZING FOR WINDOWS AND DOORS | | ON STOREFRONT.METRO DADE COUNTY OR SBCCI | | 3. BUILDING IS TYPE 2 ALL WOOD USED IN | | FRAMING SHALL BE F.R.T. TO COMPLY WITH | | 1997 SBC CHAPTER 6&7 | | 4. SUBMIT DETAIL ON DEMIZING WALLS | | SHOWING UL#.ALL FIRE RATED TENANT | | SEPERATION TO BE COMPLETE PRIOR TO C.O. | | BEING ISSUED. | | 5. SHEET A-8 DETAIL REF.S.F.B.C.SHOULD | | REF. 1997 SBC | | 6. SHEET A-9 REF. ADA, SHOULD REF. | | FLORIDA HANDICAP CODE. | | 7. SIGNS TO BE UNDER SEPERATE PERMIT. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2000-08-28 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2000-08-28 |
Time |
10:51 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2000-08-28 |
Time |
10:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2000-08-04 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2000-08-04 |
Time |
08:11 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2000-08-04 |
Time |
08:11 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | *************** UNSAT ****************** | | | | 1)NOTE: PLEASE SUBMIT CLARIFICATION ON | | FEEDER SIZES. ONE SHOWS 3/0 AND THE | | OTHER 1/0. PANEL "A" | | | | 2)NOTE;PLEASE HAVE PANEL REFLECT MCB AS | | REQ` BY NEC. | | | | 3)NOTE: PLEASE INCLUDE SHOW WINDOW OUT- | | -LETS AS PER 210-62 AND FIGURE THE LOAD | | INTO LOAD CALCS FROM 220-12B. | | | | 3)NOTE: PLEASE SHOW ALL CONTINUOUS LOADS | | AT 125% (LIGHTING) | | | | 4)NOTE: A DISCONNECT IS SHOWNBUT NO | | INFORMATION IS GIVEN? PLEASE PROVIDE | | INFORMATION ON THIS DISCONNECT ON | | RISER DIAGRAM. | | | | 5)NOTE:PLEASE PROVIDE AIC RATING FOR | | THE DISCONNECT.110-9 | | | | PLEASE SUBMIT ALL THE ABOVE INFORMATIONB | | FOR REVIEW.IF THERE ARE ANY QUESTIONS | | PLEASE CALL. | | | | DEWEY PALMER | | CITY OF WEST PALM BEACH | | 659-8096 EXT 8372 | | ELECTRICAL PLAN REVIEW. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2000-08-25 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2000-08-25 |
Time |
09:56 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2000-08-25 |
Time |
09:56 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | 1) PROVIDE FIRE ALARM SYSTEM PLANS | | FOR FIRE ALARM DEVICES SHOWN ON PLANS. | | A SEPARATE PLAN AND PERMIT IS REQUIRED. | | PROVIDE CUT SHEETS ON DEVICES PLANNED | | FOR USE. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2000-08-08 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2000-08-08 |
Time |
12:40 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | 1) NO FIRE SPRINKLER DRAWINGS INCLUDED | | WITH PLANS. | | 2) EXITING PERMITTED THROUGH STOCKROOM | | PROVIDED THE FOLLOWING CONDITIONS ARE | | MET, NOT MORE THAN 50 PERCENT OF THE | | EXIT ACCESS IS PROVIDED THROUGH | | STOCKROOM, AN AISLE OF AT LEAST 44" | | WIDE IS PRESENT, THIS 44" AISLE TO BE | | MAINTAINED, AND DOOR LEADING TO | | STOCKROOM CANNOT BE LOCKED. | | 3) INTERIOR FINISH ON WALLS AND CEILINGS | | TO BE CLASS A OR B. | | 4) PORTABLE FIRE EXTINGUISHERS REQUIRED. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2000-08-24 |
|
|
Cont ID |
|
Sent By |
ndenmark |
Date |
2000-08-24 |
Time |
13:58 |
Rev Time |
0.33 |
Received By |
ndenmark |
Date |
2000-08-24 |
Time |
13:58 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | MECH REVISIONS ADDRESS PRIOR COMMENTS | | ON MECH PLAN REVIEW |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2000-08-04 |
|
|
Cont ID |
|
Sent By |
ndenmark |
Date |
2000-08-04 |
Time |
10:14 |
Rev Time |
0.50 |
Received By |
ndenmark |
Date |
2000-08-04 |
Time |
10:14 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | *************DENIED******************** | | 1. PROVIDE OUTSIDE AIR CALCULATIONS PER | | ASHRAE 62-89 | | 2. DUCT SMOKE DETECTOR TO BE TIED TO | | BLDG FIRE ALARM PER 1996 NFPA 90A 4-4.4. | | 3. SENSIBLE CAPACITY OF SELECTED AHU | | SHALL NOT EXCEED 20% OF THE CALCULATED | | SENSIBLE LOAD.(PGAL) | | 4. SUBMIT ENERGY CALCULATION FORM 400B. | | (PGAL) | | 5. INDICATE LOCATION OF REQUIRED FIRE | | DAMPERS PER 1997 SMC 610 (PLAN INDICATES | | RATED CEILING SEE SHEET A-8) |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2000-08-24 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
2000-08-24 |
Time |
16:19 |
Rev Time |
0.65 |
Received By |
tlarge |
Date |
2000-08-24 |
Time |
16:19 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | *****************PROVISO**************** | | BENCH IN HANDICAP DRESSING ROOM SHALL BE | | LOCATED ALONG WALL W/LONGER DIMENSION. | | FACBC SEC.4.35.4. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2000-08-03 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
2000-08-03 |
Time |
18:18 |
Rev Time |
0.50 |
Received By |
tlarge |
Date |
2000-08-03 |
Time |
18:09 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | SUBMIT SQ.FOOTAGE OF SPACE TO ENSURE | | COMPLIANCE W/TABLE 407 OF SPC. | | | | 2)A DRINKING FOUNTAIN IS REQD.PER SPC | | TABLE 407.DRINKING FOUNTAIN SHALL COMPLY | | W/FACBC SEC.4.1.3.(10)(A),4.15. | | | | 3)HANDICAP DRESSING ROOM SHALL COMPLY W/ | | FACBC 4.35.BENCH SHALL BE LOCATED ALONG | | WALL WITH THE LONGER DIMENSION. | | | | 4)HANDICAP TOILET ROOM SHALL BE | | INDELIBLY POSTED FOR THE INTENDED USE | | PER FACBC SEC.4.1.2(7),4.1.3(16)(A). | | | | 5)ACCESSIBLE TOILET ROOMS SHALL BE | | LOCATED ON AN ACCESSIBLE ROUTE. | | ACCESSIBLE ROUTE SHALL BE CLEARLY | | DEFINED ON THE PLANS.FACBC SECS.4.1.3 | | (11),4.2.1,4.3.1,4.3.2(3),4.3.3. | | | | 6)TOILET FACILITIES SHALL BE AVAILABLE | | TO PATRONS WITHOUT RESTRICTION DURING | | NORMAL OPERATING HOURS.SPC SEC.407.2.2. | | | | 7)FLUSH CONTROLS FOR WATER CLOSET SHALL | | BE LOCATED ON THE WIDE SIDE OF THE | | TOILET.FACBC SEC.4.16.5. |
|
|