Plan Review Details - Permit 00070824
Plan Review Stops For Permit 00070824
Review Stop E ELECTRICAL
Rev No 3 Status P Date 2000-11-14 Cont ID  
Sent By dpalmer Date 2000-11-14 Time 10:01 Rev Time 0.00
Received By dpalmer Date 2000-11-14 Time 10:01 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2000-08-04 Cont ID  
Sent By dpalmer Date 2000-08-04 Time 15:38 Rev Time 0.00
Received By dpalmer Date 2000-08-04 Time 15:38 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2000-07-28 Cont ID  
Sent By dpalmer Date 2000-07-28 Time 05:39 Rev Time 0.00
Received By dpalmer Date 2000-07-28 Time 05:38 Sent To  
Notes
2001-01-08 00:00:00*************** UNSAT *****************
  
 1)NOTE: PLEASE SHOW GROUNDING ELECTRODE
 GOING TO BLD STEEL ALSO.250-50
  
 2)NOTE: MISSING AIC RATING FOR MAINS/
 PANEL.110-9
  
 3)NOTE: PLEASE LIST BATH(S) CIRCUIT(S)
 AS PER 210-11-C-3 MUST BE 20 AMP AND #12
 AWG.
  
 PLEASE SUBMIT THE ABOVE INFORMATION
 FOR REVIEW. IF THERE ARE ANY QUESTIONS
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 659-8096 EXT 8372

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2000-08-18 Cont ID  
Sent By rmcdouga Date 2000-08-18 Time 14:35 Rev Time 0.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-01-08 00:00:00OK PER CLYDE 7-22-00 RLM

Review Stop P PLUMBING
Rev No 3 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2000-07-22 Cont ID  
Sent By jleech Date 2000-07-22 Time 10:18 Rev Time 0.35
Received By jleech Date 2000-07-22 Time 10:18 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2000-08-18 Cont ID  
Sent By rmcdouga Date 2000-08-18 Time 14:36 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-01-08 00:00:00PROVISO
  
 1)FLOOD ELEVATION CERTIFICATE WILL BE
 REQUIRED.
  
 2)PROVIDE 2 CURRENT COPIES OF METRO-DADE
 OR SBCCI PRODUCT APPROVALS FOR GLASS
 BLOCK.
  
 3)PROVIDE 2 CURRENT COPIES OF METRO-DADE
 OR SBCCI PRODUCT APPROVALS FOR SLIDING
 GLASS DOORS. APPROVALS THAT WERE
 SUBMITTED EXPIRED ON 6-30-00.
  
 4)PROVIDE 2 SIGNED AND SEALED COPIES OF
 PAGE 4A OF PLANS SHOWING GABLE OPTION TO
 REPLACE ONES VOIDED BY MISTAKE.

Review Stop Z ZONING
Rev No 1 Status P Date 2000-07-21 Cont ID  
Sent By gjoyce Date 2000-07-21 Time 08:12 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***