Plan Review Stops For Permit 00070034 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2000-07-05 |
|
|
Cont ID |
|
Sent By |
bstaples |
Date |
2000-07-05 |
Time |
16:19 |
Rev Time |
1.00 |
Received By |
bstaples |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2000-08-09 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2000-08-09 |
Time |
15:14 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2000-08-09 |
Time |
15:14 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | ************** PROVISO *************** | | | | 1)NOTE: PLEASE SEE ARTS:225-31/225-32 | | AND ART 250 FOR REQ`MENTS FOR FOUNTAIN | | ELECTRICAL FEEDS/CIRCUITS. | | DISCONNECTS ARE REQ`D AND SEPARATE | | GROUNDING. PLEASE INCLUDE ALL STRUCTUAL | | STEEL AS PART OF GROUNDING. | | PLEASE GIVE FINAL DISTANCE AND/OR VOLT- | | -AGE DROP CALCS. | | | | PLEASE SUBMIT ALL THE ABOVE INFORMATION | | FOR REVIEW BEFORE "ANY" INSPECTION IS | | CALLED IN!!! | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-659-8096 EXT 8372 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2000-07-05 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2000-07-05 |
Time |
18:33 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2000-07-05 |
Time |
18:33 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | ***************** UNSAT **************** | | | | 1)NOTE: PLEASE NOTE THAT ONLY E-SHEET | | SUBMITTED FOR REVIEW WAS W5.0 ? | | | | PLEASE SUBMIT COMPLETE ELECTRICAL SHEETS | | FOR COMPLETE REVIEW OF WORK. IF THERE | | ARE ANY QUESTIONS PLEASE CALL. | | 561-659-8096 EXT 8372 | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
P |
Date |
2000-08-08 |
|
|
Cont ID |
|
Sent By |
dlauderm |
Date |
2000-08-08 |
Time |
15:54 |
Rev Time |
1.00 |
Received By |
dlauderm |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | PASSED WITH PROVISOS: | | WE NEED TO KNOW METER SIZE. |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2000-07-13 |
|
|
Cont ID |
|
Sent By |
mgonzale |
Date |
2000-07-13 |
Time |
13:51 |
Rev Time |
1.00 |
Received By |
mgonzale |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | FAILED | | 1.0 | | DRAWINGS SUBMITTED DO NOT SHOW TIE IN | | OFF OKEECHOBEE BLVD FOR WATER AND SEWER. | | 2.0 | | PVC PIPINGAND CONDUITS MUST BE GROUPED | | &SLEEVED TOGETHER WHEN CROSSING ROSEMARY | | AVENUE.MUST KEEP 1O'MIN AWAY FROM EX. WM | | 3.0 | | DISCHARGE FROM THE SYSTEM SHALL BE TIED | | TO SANITARY SEWER AND NOT TO THE DRAINGE | | AS CALLED OUT. | | 4.0 | | NO METERS OR BACKFLOWS ARE SHOWN IN ANY | | DRAWING. | | 5.0 | | ALL WORK PERFORMED ALONG OKEECHOBEE | | BLVD MUST BE DONE UNDER A PERMIT FROM | | FDOT. | | 6.0 | | PLEASE PROVIDE LOCATION OF ALL UTILITES | | WHERE TAPPING WILL OCCUR OR ALONG ANY | | CITY ROW WHERE WORK WILL BE PERFORM. | | THIS WILL AVOID ANY CONFLICTS IN THE | | FIELD. | | 7.0 | | TWO SETS OF PRINTS OF THE TAP WILL HAVE | | TO BE SUBMITTED TO MANNY GONZALEZ | | CITY OF WEST PALM BEACH 1000 45TH ST | | WEST PALM BEACH, FL 33409 | | 561-659-8040. | | 8.0 | | SHOPDRAWINGS WILL BE REQUIRED ON ANY | | ITEMS INSTALLED OUT IN THE ROW. SUBMITT | | 2 COPIES FOR APPROVAL. | | 9.0 | | FOR SANITARY SEWER SERVICES A CLEAN-OUT | | IS REQUIRED EVERY 75L.F. AND ONE MUST | | BE PROVIDED JUST INSIDE OF THE R.O.W. | | LINE ON PRIVATE PROPERTY. | | 10.0 | | PLEASE PROVIDE MORE DETAIL OF WHERE THE | | FOUNTAINS FALL WITHIN THE ROW AND EXIST. | | UTILIES. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2000-07-14 |
|
|
Cont ID |
|
Sent By |
fknapp |
Date |
2000-07-14 |
Time |
12:38 |
Rev Time |
0.00 |
Received By |
fknapp |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | REVIEWED OK PER M. CARSILLO |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2000-07-14 |
|
|
Cont ID |
|
Sent By |
fknapp |
Date |
2000-07-14 |
Time |
12:43 |
Rev Time |
0.00 |
Received By |
fknapp |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2000-07-26 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
2000-07-26 |
Time |
21:46 |
Rev Time |
1.00 |
Received By |
pschmitz |
Date |
2000-07-26 |
Time |
21:45 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | ***************PROVISO****************** | | 1)OVERFLOW LINE SHALL DISCHARGE TO | | STORM. | | | | 2)SUBMIT ALL SECTION DETAILS NOTED ON | | SHEET W1.3. | | | | 3)PIPE SIZES SHOWN ON SHT.W1.3 DON'T | | CORRELATE W/SIZES NOTED IN DETAIL "C" | | ON W4.8. | | | | 4)SIZE ALL PIPNG ON SHT.W2.2 AND SIZE | | PIPING ON ALL DETAILS. | | | | 5)SUBMIT ALL APPLICABLE SHEETS FOR | | REVIEW.SOME NOTED DETAILS ARE NOT ON THE | | PLANS.SUBMIT ALL DETAILS FOR REVIEW ON | | AS-BUILTS. | | | | 6)INDICATE MAKE,MODEL AND TYPE OF | | BACKFLOW PREVENTION DEVICE SHOWN IN WET | | WALL FOUNTAIN ROOM. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2000-07-07 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
2000-07-07 |
Time |
12:46 |
Rev Time |
2.00 |
Received By |
tlarge |
Date |
2000-07-07 |
Time |
12:46 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | SUBMIT ALL LISTED SHEETS FOR PLAN REVIEW | | THAT PERTAIN TO THE WET WALL FOUNTAINS. | | COUNTYWIDE AMENDMENTS TO SPC SEC.104.2.1 | | | | SHT.W0.0-NOTE (5)(G),SHT.W6.0-(C)(3)- | | DELETE REFERENCE TO UNIFORM PLUMBING | | CODE AND INSERT STANDARD PLUMBING CODE. | | COMPLY W/SPC SEC.101.1,101.2. | | | | SIZE ALL PIPING TO VAULT ON SHT.W2.2. | | AND SIZE PIPING ON ALL DETAILS. | | | | PIPE SIZES SHOWN ON SHT.W1.3 DON'T | | CORRELATE W/SIZES SHOWN IN DETAIL "C" | | ON W4.8. | | | | INDICATE MAKE,MODEL AND TYPE OF BFP | | DEVICE SHOWN IN WET WALL FOUNTAIN | | EQUIPMENT ROOM. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2000-07-06 |
|
|
Cont ID |
|
Sent By |
gjoyce |
Date |
2000-07-06 |
Time |
09:24 |
Rev Time |
0.25 |
Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|