Plan Review Details - Permit 00040982
Plan Review Stops For Permit 00040982
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2000-05-16 Cont ID  
Sent By dpalmer Date 2000-05-16 Time 18:38 Rev Time 0.00
Received By dpalmer Date 2000-05-16 Time 18:38 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2000-05-17 Cont ID  
Sent By cthirben Date 2000-05-17 Time 07:36 Rev Time 1.00
Received By cthirben Date 2000-05-17 Time 07:36 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2000-05-16 Cont ID  
Sent By tlarge Date 2000-05-16 Time 18:39 Rev Time 0.33
Received By tlarge Date 2000-05-16 Time 18:39 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2000-06-22 Cont ID  
Sent By fknapp Date 2000-06-22 Time 11:14 Rev Time 2.00
Received By fknapp Date 2000-06-22 Time 11:14 Sent To  
Notes
2001-01-08 00:00:00 
  
  
 *****************PROVISO****************
  
 SBC 104.2.2
  
 1)PROVIDE 2 CURRENT COPIES OF SBCCI OR
 METRODADE PRODUCT APPROVAL FOR .50
 ALUMINUM STORM PANELS WITH INSTALLATION
 SCHEDULE AND KEY PLAN WITH SPECIFIC
 ANCHORS FOR ALL STORM PANELS TO BE USED
 UNDER SEPERATE PERMIT.
  
 2)PROVIDE 1 HOUR PROTECTION THRUOUT
 BUILDING TO COMPLY WITH TABLE 500 FOR
 3 STORIES.
  
 3)PROVIDE 1 HOUR UL LISTED FLOOR AND
 CEILING ASSEMBLY AS ATTACHED TO PLANS.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2000-06-14 Cont ID  
Sent By fknapp Date 2000-06-14 Time 20:44 Rev Time 4.00
Received By fknapp Date 2000-06-14 Time 17:50 Sent To  
Notes
2001-01-08 00:00:00 
 **************UNSAT*********************
  
 SBC 104.2.2
  
 1)PROVIDE SOIL REPORT
  
 2)PROVIDE MANUEL J FORM
  
 3)PROVIDE DESIGN PRESSURES ON ALL
 EXTERIOR OPENINGS
  
 4)PROVIDE DESIGN CERTIFICATION FOR
 BUILDING CODE COMPLIANCE
  
 5)PROVIDE 2 CURRENT COMPLETE COPIES OF
 SBCCI OR METRO DADE PRODUCT APPROVALS
 FOR:
 EXTERIOR LVR DOOR UNIT
 BATHROOM WINDOWS
 .50 ALUMINUM STORM PANELS
  
 6)PROVIDE INSTALLATION SCHEDULE AND KEY
 PLAN WITH SPECIFIC ANCHORS TO BE USED
 FOR ALL STORM PANELS
  
 7)PROVIDE LENGHT OF J BOLTS FOR LEDGER
 ON 2ND FLOOR FRAMING
  
 8)PROVIDE DETAILS FOR PORCH RAILINGS
  
 9)PROVIDE STAIR SECTION DETAILS WITH
 TREAD,RISER,HANDRAIL,GUARDRAIL
 DIMENSIONS SBC 1006,1007,1015
  
 10)PROVIDE ATTIC ACCESS AND VENTILATION
 SBC 2309.6, 2309.7
  
 11)TYPE OF CONSTRUCTION DOES NOT COMPLY
 WITH SBC TBL 500,BUILDING EXCEEDS
 2 STORIES, REVISE TO COMPLY
  
 12)BEFORE A PERMIT TO CONSTRUCT CAN BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH CO., THE PERMIT PLANS STAMPED BY
 THEM AND THE RECEIPT ATTACHED TO THE
 PERMIT APPLICATION.

Review Stop Z ZONING
Rev No 1 Status P Date 2000-05-15 Cont ID  
Sent By gjoyce Date 2000-04-21 Time 13:03 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
2001-01-08 00:00:00NEED HISTORIC APPROVAL