Plan Review Details - Permit 00020987
Plan Review Stops For Permit 00020987
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2000-03-31 Cont ID  
Sent By lsmith Date 2000-03-31 Time 08:26 Rev Time 2.00
Received By lsmith Date   Time   Sent To  
Notes
2001-01-08 00:00:00PROVISO: NEED PRODUCT APPROVALS FOR
 WINDOWS & SINGLE ENTRY DOOR & ENGINEERED
 TRUSS DRAWINGS, ORIGINAL ENERGY FORM
 SIGNED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2000-02-23 Cont ID  
Sent By jwitmer Date 2000-02-23 Time 10:17 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2001-01-08 00:00:00REQUIRE GC,WORKERS COMP EXEMPT
 CERTIFICATE OK FOR ISSUANCE JW 2/23/2000

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2000-03-07 Cont ID  
Sent By dpalmer Date 2000-03-07 Time 10:20 Rev Time 0.00
Received By dpalmer Date 2000-03-07 Time 10:20 Sent To  
Notes
2001-01-08 00:00:00**************** PROVISO ***************
  
 1)NOTE: NEED TO SHOW THE SIZE OF THE
 EXISTING SERVICE. NEED TO SUBMIT NEW
 LOAD CALCULATION TO INCLUDE NEW A/C
 LOAD BEINGADDED.
  
 2)NOTE: AS REQ`D BY 210-52D/210-11-C-3
 BATH CIRCUT TO BE DEDICATED.
  
 3)NOTE: AS PER 110-16 NOTE CLEARENCE FOR
 AHU.
  
 4)NOTE: AS REQ`D BY NFPA-72 2-2.1.1.1
 SMOKE DETECTORS ARE REQ`D INSIDE AND
 OUTSIDEALL SLEEPING ROOMS.
  
 PLEASE SUBMIT FOR REVIEW AND APPROVAL
 BEFORE ROUGH INSPECTION. IF THERE ARE
 ANY QUESTIONS PLEASE CALL 659-8096 X
 8372

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2000-03-29 Cont ID  
Sent By cthirben Date 2000-03-29 Time 12:02 Rev Time 1.00
Received By cthirben Date 2000-03-29 Time 12:02 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2000-03-10 Cont ID  
Sent By cthirben Date 2000-03-10 Time 10:11 Rev Time 1.00
Received By cthirben Date 2000-03-10 Time 10:07 Sent To  
Notes
2001-01-08 00:00:00****************DENIED*****************
 1. INDICATE SIZE OF EXHAUST FANS
 2. SIZE OF WINDOW NO: 1A4SH
 3. SIZE OF A/C AND ENERGY CALCULATIONS
 REQUIRED
 4. SIZE OF DUCTS

Review Stop P PLUMBING
Rev No 1 Status P Date 2000-03-07 Cont ID  
Sent By tlarge Date 2000-03-07 Time 06:59 Rev Time 0.33
Received By tlarge Date 2000-03-07 Time 06:59 Sent To  
Notes
2001-01-08 00:00:00GAS DRWG.REQD.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2000-03-31 Cont ID  
Sent By lsmith Date 2000-03-21 Time 13:55 Rev Time 0.50
Received By lsmith Date   Time   Sent To  
Notes
2001-01-08 00:00:00NEED FOLLOWING:
 1. PRODUCT APPROVALS (DADE CTY OR SBCCI)
 FOR WINDOWS & DOORS
 2. NEED ENGINEERED SEALED DRAWINGS FOR
 TRUSSES.

Review Stop Z ZONING
Rev No 1 Status P Date 2000-02-28 Cont ID  
Sent By gjoyce Date 2000-02-28 Time 14:25 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***