Plan Review Details - Permit 00020987
Plan Review Stops For Permit 00020987 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2000-03-31 |
|
|
Cont ID |
|
Sent By |
lsmith |
Date |
2000-03-31 |
Time |
08:26 |
Rev Time |
2.00 |
Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | PROVISO: NEED PRODUCT APPROVALS FOR | | WINDOWS & SINGLE ENTRY DOOR & ENGINEERED | | TRUSS DRAWINGS, ORIGINAL ENERGY FORM | | SIGNED. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2000-02-23 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2000-02-23 |
Time |
10:17 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | REQUIRE GC,WORKERS COMP EXEMPT | | CERTIFICATE OK FOR ISSUANCE JW 2/23/2000 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2000-03-07 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2000-03-07 |
Time |
10:20 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2000-03-07 |
Time |
10:20 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | **************** PROVISO *************** | | | | 1)NOTE: NEED TO SHOW THE SIZE OF THE | | EXISTING SERVICE. NEED TO SUBMIT NEW | | LOAD CALCULATION TO INCLUDE NEW A/C | | LOAD BEINGADDED. | | | | 2)NOTE: AS REQ`D BY 210-52D/210-11-C-3 | | BATH CIRCUT TO BE DEDICATED. | | | | 3)NOTE: AS PER 110-16 NOTE CLEARENCE FOR | | AHU. | | | | 4)NOTE: AS REQ`D BY NFPA-72 2-2.1.1.1 | | SMOKE DETECTORS ARE REQ`D INSIDE AND | | OUTSIDEALL SLEEPING ROOMS. | | | | PLEASE SUBMIT FOR REVIEW AND APPROVAL | | BEFORE ROUGH INSPECTION. IF THERE ARE | | ANY QUESTIONS PLEASE CALL 659-8096 X | | 8372 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2000-03-29 |
|
|
Cont ID |
|
Sent By |
cthirben |
Date |
2000-03-29 |
Time |
12:02 |
Rev Time |
1.00 |
Received By |
cthirben |
Date |
2000-03-29 |
Time |
12:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2000-03-10 |
|
|
Cont ID |
|
Sent By |
cthirben |
Date |
2000-03-10 |
Time |
10:11 |
Rev Time |
1.00 |
Received By |
cthirben |
Date |
2000-03-10 |
Time |
10:07 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | ****************DENIED***************** | | 1. INDICATE SIZE OF EXHAUST FANS | | 2. SIZE OF WINDOW NO: 1A4SH | | 3. SIZE OF A/C AND ENERGY CALCULATIONS | | REQUIRED | | 4. SIZE OF DUCTS |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2000-03-07 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
2000-03-07 |
Time |
06:59 |
Rev Time |
0.33 |
Received By |
tlarge |
Date |
2000-03-07 |
Time |
06:59 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | GAS DRWG.REQD. |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
P |
Date |
2000-03-31 |
|
|
Cont ID |
|
Sent By |
lsmith |
Date |
2000-03-21 |
Time |
13:55 |
Rev Time |
0.50 |
Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | NEED FOLLOWING: | | 1. PRODUCT APPROVALS (DADE CTY OR SBCCI) | | FOR WINDOWS & DOORS | | 2. NEED ENGINEERED SEALED DRAWINGS FOR | | TRUSSES. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2000-02-28 |
|
|
Cont ID |
|
Sent By |
gjoyce |
Date |
2000-02-28 |
Time |
14:25 |
Rev Time |
0.25 |
Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
|