Plan Review Details - Permit 00020939
Plan Review Stops For Permit 00020939
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2000-03-07 Cont ID  
Sent By bstaples Date 2000-03-07 Time 08:36 Rev Time 1.00
Received By bstaples Date   Time   Sent To  
Notes
2001-01-08 00:00:00ALL PUBLIC AREAS SHALL BE ACCESSABLE TO
 THE PHYSICALLY HANDICAPPED.

Review Stop E ELECTRICAL
Rev No 7 Status P Date 2000-10-17 Cont ID  
Sent By dpalmer Date 2000-10-17 Time 10:17 Rev Time 0.00
Received By dpalmer Date 2000-10-17 Time 10:17 Sent To  
Notes
2001-01-08 00:00:00REV FOR DECREASE IN TWO PUMPS DOWN TO
 3/4 HP.

Review Stop E ELECTRICAL
Rev No 6 Status P Date 2000-07-05 Cont ID  
Sent By dpalmer Date 2000-07-05 Time 19:16 Rev Time 0.00
Received By dpalmer Date 2000-07-05 Time 19:16 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 5 Status F Date 2000-06-07 Cont ID  
Sent By dpalmer Date 2000-06-07 Time 22:24 Rev Time 0.00
Received By dpalmer Date 2000-06-07 Time 22:24 Sent To  
Notes
2001-01-08 00:00:00**************** UNSAT *****************
  
 1)NOTE: LOAD CALCULATION STILL NEEDS TO
 BE RE-DONE. MCC-S IS STILL SHOWING LOAD
 FROM BEFORE WHEN DIMMER PACK LOADS
 WERE NOT FIGURED AT 125%. THIS WILL
 CHANGE LOAD CALCUALTION SHOWN ON MCC-S
  
 2)NOTE: PLEASE CAHNGE ON RISER.STILL
 SHOWS 293A
  
 3)NOTE: PLEASE CORRECT LOAD CALCULATION
 FOR MCC-S. CONNECTED LOAD SHOWN AT 175??
 WHEN CONNECTED LOAD FOR MOTORS ARE 189A
 WHICH IS WHAT YOU SHOW FURTHER DOWN.
 125% IS FIGURED FOR LARGEST MOTOR ONLY??
 WHERE IS THE 58AMPS COMING FROM.
  
 4)NOTE: PLEASE INCLUDE A NOTEON PLANS
 FOR CLASS A PROTECTION FOR PUMPS IN
 FOUNTAIN. PLEASE NOTE FOR SETTING OF
 GFI PROTECTION ON VFD`S LIKE YOU HAVE
 FOR LIGHTING.
  
 5)NOTE: PLEASE MAKE THE CORRECTION FOR
 THE AIC RATING OF MAIN ON SWITCHBOARD--
 "PB". I HAVE SPOKEN TO ELECTRICAL
 CONTRACTOR AND IT IS MY UNDERSTANDING
 THAT THE MAIN IS GOING TO BE INCREASED
 FOR THE AVAILABLE FAULT CURRENT??
 PLEASE VERIFY AND SHOW THE RATING OF
 MAIN BEING INSTALLED.215-5
  
 PLEASE SUBMIT ALL THE ABOVE INFORMATION
 FOR REVIEW. WE ARE STILL WAITING FOR
 SHOP DRAWINGS/SPEC BOOKS??? PLEASE
 SUBMIT WITH PLANS. IF THERE ARE ANY
 QUESTIONS PLEASE CALL 561-659-8096 EXT -
 8372

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2000-05-18 Cont ID  
Sent By dpalmer Date 2000-05-18 Time 12:10 Rev Time 0.00
Received By dpalmer Date 2000-05-18 Time 12:10 Sent To  
Notes
2001-01-08 00:00:00**************** UNSAT *****************
  
 PLEASE NOTE THAT SOME OF THE ORIGINAL
 COMMENTS WERENOT ADDRESSED.
  
 1)NOTE: STILL NEED TO SEE W-5.7 FOR THE
 LOAD THAT YOUARE SHOWING FOR LIGHTING.
 YOU ARE SHOWWING LOAD FOR DIMMER PACK 'B
 AT 234 AMPS. THIS IS CORRECT BUT ON W5.4
 YOU SHOW LOAD AT 200 AMPS???
 PLEASE CORRECT.
  
 2)NOTE:ALSO, THE FEEDER WIRES FOR BOTH
 DIMMER PACKS SHOWN ARE NOT RATED FOR THE
 LOADS.
 PLEASE CHANGE DTO CORRECT WIRE SIZE AS
 PER 310-16..
  
 3)NOTE : SINCE THE LOAD SHOWN ON W5.4
 FOR DIMMER 'B' DOES NOT MATCH CORRECT
 LOAD SHOWN ON W5.7. THE TOTAL LOAD FOR
 MCC-S WILL HAVE TO CHANGE ALSO.
  
 4)NOTE: AS PREVIOUS NOTES STATES, PLEASE
 SHOW THE LOAD FOR MCC-S WITH THE ADDED
 25% FOR LARGEST MOTOR.PLEASE SHOW FIGS.
  
 5)NOTE: YOU ARE SHOWING THE AIC RATING
 FOR THE PANEL SWITCHBOARD 'PB' AS BEING
 10,000 AIC. PLEASE SUBMIT FAULT CURRENT
 CALCULATIONS FOR THIS. YOU SHOW A 300KVA
 TRANSFORMER NEXT TO PNAEL 'PB'. 110-9
 215-5
  
 ****************************************
  
 1)NOTE: AFTER REVIEWING SPECS FOR THE
 INSTALLATION OF THE "BENDER" GFI MODULES
 ANY MODULES INSTALLED MUST MEET THE
 UL 943 CLASS'A' WITH PROTECTION SET AT
 6MA OR LESS FOR PERSONNEL PROTECTION.
 AS PER 680-51.
  
 2)NOTE: ON W4.5 ALL FITTINGS USED FOR
 GROUNDING/BONDING IN AND ABOUT FOUNTAIN
 ARE TO BE LISTED FOR USE AS DIRECT
 BURIAL AND CONCRETE ENCASEMENT.
  
  
 PLEASE SUBMIT ALL THE ABOVE INFORMATION
 FOR REVIEW. IF THERE ARE ANY QUESTIONS
 PLEASE CALL 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2000-03-21 Cont ID  
Sent By dpalmer Date 2000-03-21 Time 19:32 Rev Time 0.00
Received By dpalmer Date 2000-03-21 Time 19:32 Sent To  
Notes
2001-01-08 00:00:00*************** UNSAT ******************
  
 1)NOTE: MOTOR LOAD ON MCC-S;NEEDS TO
 SHOW 25% OF LARGEST MOTOR SHOWN IN TOTAL
 LOAD.THAT WILL AFFECT TOTAL LOAD SHOWN.
  
 2)NOTE: YOU SHOW ON W5-6 AND W5-7
 LOAD FOR LIGHTING AT 125%. THIS IS
 CORRECT BUT ON W5-4 YOU DO NOT SHOW THE
 SAME LOAD CARRIED OVER FROM THOSE PAGES.
  
 3)NOTE: FEEDERS FOR DIMMER PACKS NEED TO
 BE RATED FOR THE LOADS. ALSO CHECK TO
 MAKE SURE THAT OVERCURRENT PROTECTION
 IS ADEQUATE. FEEDERS MUST BE SIZED
 ACCORDINGLY.
  
 4)NOTE: SINCE THE LOADS FOR THE DIMMER
 PACKSARE HIGHER THEN NEW TOTAL LOAD
 WILL CHANGE TRANSFORMER T-1 LOAD.
  
 PLEASE SUBMIT NEW REVISED PLANS FOR
 REVIEW AND APPROVAL. IF THERE ARE ANY
 QUESTIONS PLEASE CALL 659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2000-03-21 Cont ID  
Sent By jleahy Date 2000-03-15 Time 10:16 Rev Time 0.00
Received By dpalmer Date 2000-03-15 Time 10:17 Sent To  
Notes
2001-01-08 00:00:001-NOT ENOUGH INFORMATION FOR A PLAN
 REVIEW
  
 2-PROVIDE ELECTRICAL PLANS SHOWING ALL
 ELECTRICAL WORK TO BE DONE!!!!!!!!!!
  
 3-RISER DIAGRAM, PANEL SCHEDULES, AIC
 LOAD CALCULATION, BRANCH CKT NUMBERS
 ECT. ECT.ECT.
 4.REVISED STATUS TO PROVISO WRS 3/15/0

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2000-03-08 Cont ID  
Sent By dpalmer Date 2000-03-08 Time 06:47 Rev Time 0.00
Received By dpalmer Date 2000-03-08 Time 06:47 Sent To  
Notes
2001-01-08 00:00:00NE ELECTRICAL PLANS, FRONT COVER SHEET
 SAYS ELEC.PENDING.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2000-03-07 Cont ID  
Sent By bstaples Date 2000-03-07 Time 08:26 Rev Time 1.00
Received By bstaples Date   Time   Sent To  
Notes
2001-01-08 00:00:00REVIEW BY M. CARSILLO SEE NOTES ON PLAN

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2000-03-21 Cont ID  
Sent By ndenmark Date 2000-03-21 Time 06:50 Rev Time 0.25
Received By ndenmark Date 2000-03-21 Time 06:50 Sent To  
Notes
2001-01-08 00:00:00NO MECH DETAILS TO REVIEW PROVIDE PLANS
 WITH MECH PERMIT APPLICATION PRIOR TO
 ANY MECH WORK BEING DONE

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2000-03-08 Cont ID  
Sent By ndenmark Date 2000-03-08 Time 12:45 Rev Time 0.33
Received By ndenmark Date 2000-03-08 Time 12:45 Sent To  
Notes
2001-01-08 00:00:00NO MECH DETAILS FOR A/C EQUIPMENT SHOWN
 PROVIDE DETAILED PLANS WITH MECH PERMIT
 APPLICATION

Review Stop P PLUMBING
Rev No 5 Status F Date 2000-09-21 Cont ID  
Sent By tlarge Date 2000-09-21 Time 09:21 Rev Time 3.75
Received By tlarge Date 2000-09-17 Time 07:11 Sent To  
Notes
2001-01-08 00:00:001)APPROVAL LISTING FROM A NATIONALLY
 RECOGNIZED AGENCY SHALL BE SUBMITTED FOR
 THE FOLLOWING ITEMS:
 CO2 FEED SYSTEM
 T-W CO2 LIQUIDATOR AND BULK CO2 SYSTEM
 TOXIC LEAK DETECTORS
 CHEMICAL TREATMENT SYSTEM (US FILTER)
 PROBE CLEANING SYSTEM
 HYPOCHLORITE FEEDER
 ACID PUMP
 WALL OVERFLOW AND SKIMMER
 AIR COMPRESSOR AND DRYER
 FOG SYSTEM
 FILTER PUMP
 UTILITY FAN
 SUMP PUMPS
 FOUNTAIN PUMPS
 PROTECTOEPOXY
 REFER TO STANDARD BUILDING CODE 1997
 EDITION CHAPTER 35 FOR LISTING OF
 REFERENCED STANDARDS AND STANDARD
 PLUMBING CODE 1994 EDITION CHAPTER 17.
  
 CALL 561-659-8096,EXT.8377 IF YOU HAVE
 QUESTIONS.
 TIMOTHY LARGE
 PLUMBING PLANS EXAMINER.

Review Stop P PLUMBING
Rev No 4 Status P Date 2000-06-16 Cont ID  
Sent By tlarge Date 2000-06-16 Time 11:35 Rev Time 4.50
Received By tlarge Date 2000-06-16 Time 11:35 Sent To  
Notes
2001-01-08 00:00:00*****************PROVISO****************
 PRESSURE FITTINGS OVER 12"-SUBMIT
 COMPLETE TEST REPORTS FROM TESTING
 AGENCY,CONTRACTED BY FREEDOM PLASTICS.
 APPROVAL OF FITTINGS OVER 12"IS
 CONTINGENT UPON REVIEW AND ACCEPTANCE OF
 TEST REPORTS.
  
 2)SUBMIT A COMPLETE PIPING DIAGRAM
 FOR THE COMPRESSED AIR AND MURIATIC ACID
 SYSTEMS.COUNTYWIDE AMENDMENTS TO SPC
 SEC.104.2.1.

Review Stop P PLUMBING
Rev No 3 Status P Date 2000-05-20 Cont ID  
Sent By pschmitz Date 2000-05-20 Time 10:03 Rev Time 2.00
Received By pschmitz Date   Time   Sent To  
Notes
2001-01-08 00:00:00PLUMBING PROVISO:
 (1)PRESSURE FITTINGS OVER 12", SUBMIT
 COMPLETE TEST REPORTS FROM TESTING
 AGENCY, CONTRACTED BY FREEDOM PLASTICS.
 APPROVAL OF FITTINGS OVER 12" IS
 CONTNGENT UPON REVIEW AND ACCEPTANCE
 OF TEST REPORTS.
 (2) MURIATIC ACID AND COMPRESSED AIR
 LINES,SUBMIT A COMPLETE PIPING DIAGRAMS.
 CNTY WIDE AMENDMENTS SEC 104.2.1
 END OF COMMENTS

Review Stop P PLUMBING
Rev No 2 Status F Date 2000-03-23 Cont ID  
Sent By tlarge Date 2000-03-23 Time 16:16 Rev Time 1.25
Received By tlarge Date 2000-03-23 Time 16:08 Sent To  
Notes
2001-01-08 00:00:00 
 1)NOTES REFER TO FLOOR DRAINAGE.SUBMIT
 DRAWING FOR ALL FLOOR DRAINAGE TO BE
 PROVIDED.DRAINS SHALL DISCHARGE TO AN
 APPROVED LOCATION.COUNTYWIDE AMENDMENTS
 TO SPC SEC.104.2.1.
  
 2)SUBMIT DETAILS FOR SUMP PUMP PIPING.
 DRAIN SHALL DISCHARGE TO AN APPROVED
 LOCTION.
  
 3)PLANS NOTE BACKWASH LINES DISCHARGING
 TO"SANITARY P-TRAP."SUBMIT DETAILS FOR
 THESE CONNECTIONS AND SHOW TERMINATION
 POINTS OF ALL DRAINS.
  
 4)SUBMIT POTABLE WATER RISER DIAGRAM
 FOR REVIEW.
  
 5)SUBMIT PIPING DIAGRAMS FOR POOL ACID
 AND COMPRESSED AIR PIPING.
 COUNTYWIDE AMENDMENTS TO SPC SEC.104.2.1
  
 THE ABOVE INFORMATION MUST BE SUBMITTED
 PRIOR TO ROUGH PLBG. INSPECTION.

Review Stop P PLUMBING
Rev No 1 Status P Date 2000-02-26 Cont ID  
Sent By tlarge Date 2000-02-26 Time 08:26 Rev Time 2.00
Received By tlarge Date 2000-02-26 Time 08:26 Sent To  
Notes
2001-01-08 00:00:00******************PROVISO***************
 PIPING SCHEMATICS REQD.FOR POOL ACID AND
 COMPRESSED AIR PIPING PRIOR TO RGH.
 INSPECTION.
  
 SUBMIT DETAILS/RISER DIAGRAM FOR FLOOR
 DRAINAGE.DRAINS SHALL DISCHARGE TO
 AN APPROVED LOCATION.
 COUNTYWIDE AMENDMENTS TO SPC SEC.104.2.1

Review Stop Z ZONING
Rev No 1 Status P Date 2000-03-10 Cont ID  
Sent By bstaples Date 2000-03-10 Time 09:50 Rev Time 1.00
Received By bstaples Date   Time   Sent To  
Notes
2001-01-08 00:00:00APPROVED DENNIS CAMPBELL 3/8/00