Plan Review Stops For Permit 00020939 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2000-03-07 |
|
|
Cont ID |
|
Sent By |
bstaples |
Date |
2000-03-07 |
Time |
08:36 |
Rev Time |
1.00 |
Received By |
bstaples |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | ALL PUBLIC AREAS SHALL BE ACCESSABLE TO | | THE PHYSICALLY HANDICAPPED. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
7 |
Status |
P |
Date |
2000-10-17 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2000-10-17 |
Time |
10:17 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2000-10-17 |
Time |
10:17 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | REV FOR DECREASE IN TWO PUMPS DOWN TO | | 3/4 HP. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
6 |
Status |
P |
Date |
2000-07-05 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2000-07-05 |
Time |
19:16 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2000-07-05 |
Time |
19:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
F |
Date |
2000-06-07 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2000-06-07 |
Time |
22:24 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2000-06-07 |
Time |
22:24 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | **************** UNSAT ***************** | | | | 1)NOTE: LOAD CALCULATION STILL NEEDS TO | | BE RE-DONE. MCC-S IS STILL SHOWING LOAD | | FROM BEFORE WHEN DIMMER PACK LOADS | | WERE NOT FIGURED AT 125%. THIS WILL | | CHANGE LOAD CALCUALTION SHOWN ON MCC-S | | | | 2)NOTE: PLEASE CAHNGE ON RISER.STILL | | SHOWS 293A | | | | 3)NOTE: PLEASE CORRECT LOAD CALCULATION | | FOR MCC-S. CONNECTED LOAD SHOWN AT 175?? | | WHEN CONNECTED LOAD FOR MOTORS ARE 189A | | WHICH IS WHAT YOU SHOW FURTHER DOWN. | | 125% IS FIGURED FOR LARGEST MOTOR ONLY?? | | WHERE IS THE 58AMPS COMING FROM. | | | | 4)NOTE: PLEASE INCLUDE A NOTEON PLANS | | FOR CLASS A PROTECTION FOR PUMPS IN | | FOUNTAIN. PLEASE NOTE FOR SETTING OF | | GFI PROTECTION ON VFD`S LIKE YOU HAVE | | FOR LIGHTING. | | | | 5)NOTE: PLEASE MAKE THE CORRECTION FOR | | THE AIC RATING OF MAIN ON SWITCHBOARD-- | | "PB". I HAVE SPOKEN TO ELECTRICAL | | CONTRACTOR AND IT IS MY UNDERSTANDING | | THAT THE MAIN IS GOING TO BE INCREASED | | FOR THE AVAILABLE FAULT CURRENT?? | | PLEASE VERIFY AND SHOW THE RATING OF | | MAIN BEING INSTALLED.215-5 | | | | PLEASE SUBMIT ALL THE ABOVE INFORMATION | | FOR REVIEW. WE ARE STILL WAITING FOR | | SHOP DRAWINGS/SPEC BOOKS??? PLEASE | | SUBMIT WITH PLANS. IF THERE ARE ANY | | QUESTIONS PLEASE CALL 561-659-8096 EXT - | | 8372 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
F |
Date |
2000-05-18 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2000-05-18 |
Time |
12:10 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2000-05-18 |
Time |
12:10 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | **************** UNSAT ***************** | | | | PLEASE NOTE THAT SOME OF THE ORIGINAL | | COMMENTS WERENOT ADDRESSED. | | | | 1)NOTE: STILL NEED TO SEE W-5.7 FOR THE | | LOAD THAT YOUARE SHOWING FOR LIGHTING. | | YOU ARE SHOWWING LOAD FOR DIMMER PACK 'B | | AT 234 AMPS. THIS IS CORRECT BUT ON W5.4 | | YOU SHOW LOAD AT 200 AMPS??? | | PLEASE CORRECT. | | | | 2)NOTE:ALSO, THE FEEDER WIRES FOR BOTH | | DIMMER PACKS SHOWN ARE NOT RATED FOR THE | | LOADS. | | PLEASE CHANGE DTO CORRECT WIRE SIZE AS | | PER 310-16.. | | | | 3)NOTE : SINCE THE LOAD SHOWN ON W5.4 | | FOR DIMMER 'B' DOES NOT MATCH CORRECT | | LOAD SHOWN ON W5.7. THE TOTAL LOAD FOR | | MCC-S WILL HAVE TO CHANGE ALSO. | | | | 4)NOTE: AS PREVIOUS NOTES STATES, PLEASE | | SHOW THE LOAD FOR MCC-S WITH THE ADDED | | 25% FOR LARGEST MOTOR.PLEASE SHOW FIGS. | | | | 5)NOTE: YOU ARE SHOWING THE AIC RATING | | FOR THE PANEL SWITCHBOARD 'PB' AS BEING | | 10,000 AIC. PLEASE SUBMIT FAULT CURRENT | | CALCULATIONS FOR THIS. YOU SHOW A 300KVA | | TRANSFORMER NEXT TO PNAEL 'PB'. 110-9 | | 215-5 | | | | **************************************** | | | | 1)NOTE: AFTER REVIEWING SPECS FOR THE | | INSTALLATION OF THE "BENDER" GFI MODULES | | ANY MODULES INSTALLED MUST MEET THE | | UL 943 CLASS'A' WITH PROTECTION SET AT | | 6MA OR LESS FOR PERSONNEL PROTECTION. | | AS PER 680-51. | | | | 2)NOTE: ON W4.5 ALL FITTINGS USED FOR | | GROUNDING/BONDING IN AND ABOUT FOUNTAIN | | ARE TO BE LISTED FOR USE AS DIRECT | | BURIAL AND CONCRETE ENCASEMENT. | | | | | | PLEASE SUBMIT ALL THE ABOVE INFORMATION | | FOR REVIEW. IF THERE ARE ANY QUESTIONS | | PLEASE CALL 561-659-8096 EXT 8372 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2000-03-21 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2000-03-21 |
Time |
19:32 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2000-03-21 |
Time |
19:32 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | *************** UNSAT ****************** | | | | 1)NOTE: MOTOR LOAD ON MCC-S;NEEDS TO | | SHOW 25% OF LARGEST MOTOR SHOWN IN TOTAL | | LOAD.THAT WILL AFFECT TOTAL LOAD SHOWN. | | | | 2)NOTE: YOU SHOW ON W5-6 AND W5-7 | | LOAD FOR LIGHTING AT 125%. THIS IS | | CORRECT BUT ON W5-4 YOU DO NOT SHOW THE | | SAME LOAD CARRIED OVER FROM THOSE PAGES. | | | | 3)NOTE: FEEDERS FOR DIMMER PACKS NEED TO | | BE RATED FOR THE LOADS. ALSO CHECK TO | | MAKE SURE THAT OVERCURRENT PROTECTION | | IS ADEQUATE. FEEDERS MUST BE SIZED | | ACCORDINGLY. | | | | 4)NOTE: SINCE THE LOADS FOR THE DIMMER | | PACKSARE HIGHER THEN NEW TOTAL LOAD | | WILL CHANGE TRANSFORMER T-1 LOAD. | | | | PLEASE SUBMIT NEW REVISED PLANS FOR | | REVIEW AND APPROVAL. IF THERE ARE ANY | | QUESTIONS PLEASE CALL 659-8096 EXT 8372 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2000-03-21 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2000-03-15 |
Time |
10:16 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2000-03-15 |
Time |
10:17 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | 1-NOT ENOUGH INFORMATION FOR A PLAN | | REVIEW | | | | 2-PROVIDE ELECTRICAL PLANS SHOWING ALL | | ELECTRICAL WORK TO BE DONE!!!!!!!!!! | | | | 3-RISER DIAGRAM, PANEL SCHEDULES, AIC | | LOAD CALCULATION, BRANCH CKT NUMBERS | | ECT. ECT.ECT. | | 4.REVISED STATUS TO PROVISO WRS 3/15/0 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
N |
Date |
2000-03-08 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2000-03-08 |
Time |
06:47 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2000-03-08 |
Time |
06:47 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | NE ELECTRICAL PLANS, FRONT COVER SHEET | | SAYS ELEC.PENDING. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2000-03-07 |
|
|
Cont ID |
|
Sent By |
bstaples |
Date |
2000-03-07 |
Time |
08:26 |
Rev Time |
1.00 |
Received By |
bstaples |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | REVIEW BY M. CARSILLO SEE NOTES ON PLAN |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
N |
Date |
2000-03-21 |
|
|
Cont ID |
|
Sent By |
ndenmark |
Date |
2000-03-21 |
Time |
06:50 |
Rev Time |
0.25 |
Received By |
ndenmark |
Date |
2000-03-21 |
Time |
06:50 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | NO MECH DETAILS TO REVIEW PROVIDE PLANS | | WITH MECH PERMIT APPLICATION PRIOR TO | | ANY MECH WORK BEING DONE |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2000-03-08 |
|
|
Cont ID |
|
Sent By |
ndenmark |
Date |
2000-03-08 |
Time |
12:45 |
Rev Time |
0.33 |
Received By |
ndenmark |
Date |
2000-03-08 |
Time |
12:45 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | NO MECH DETAILS FOR A/C EQUIPMENT SHOWN | | PROVIDE DETAILED PLANS WITH MECH PERMIT | | APPLICATION |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
F |
Date |
2000-09-21 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
2000-09-21 |
Time |
09:21 |
Rev Time |
3.75 |
Received By |
tlarge |
Date |
2000-09-17 |
Time |
07:11 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | 1)APPROVAL LISTING FROM A NATIONALLY | | RECOGNIZED AGENCY SHALL BE SUBMITTED FOR | | THE FOLLOWING ITEMS: | | CO2 FEED SYSTEM | | T-W CO2 LIQUIDATOR AND BULK CO2 SYSTEM | | TOXIC LEAK DETECTORS | | CHEMICAL TREATMENT SYSTEM (US FILTER) | | PROBE CLEANING SYSTEM | | HYPOCHLORITE FEEDER | | ACID PUMP | | WALL OVERFLOW AND SKIMMER | | AIR COMPRESSOR AND DRYER | | FOG SYSTEM | | FILTER PUMP | | UTILITY FAN | | SUMP PUMPS | | FOUNTAIN PUMPS | | PROTECTOEPOXY | | REFER TO STANDARD BUILDING CODE 1997 | | EDITION CHAPTER 35 FOR LISTING OF | | REFERENCED STANDARDS AND STANDARD | | PLUMBING CODE 1994 EDITION CHAPTER 17. | | | | CALL 561-659-8096,EXT.8377 IF YOU HAVE | | QUESTIONS. | | TIMOTHY LARGE | | PLUMBING PLANS EXAMINER. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2000-06-16 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
2000-06-16 |
Time |
11:35 |
Rev Time |
4.50 |
Received By |
tlarge |
Date |
2000-06-16 |
Time |
11:35 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | *****************PROVISO**************** | | PRESSURE FITTINGS OVER 12"-SUBMIT | | COMPLETE TEST REPORTS FROM TESTING | | AGENCY,CONTRACTED BY FREEDOM PLASTICS. | | APPROVAL OF FITTINGS OVER 12"IS | | CONTINGENT UPON REVIEW AND ACCEPTANCE OF | | TEST REPORTS. | | | | 2)SUBMIT A COMPLETE PIPING DIAGRAM | | FOR THE COMPRESSED AIR AND MURIATIC ACID | | SYSTEMS.COUNTYWIDE AMENDMENTS TO SPC | | SEC.104.2.1. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2000-05-20 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
2000-05-20 |
Time |
10:03 |
Rev Time |
2.00 |
Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | PLUMBING PROVISO: | | (1)PRESSURE FITTINGS OVER 12", SUBMIT | | COMPLETE TEST REPORTS FROM TESTING | | AGENCY, CONTRACTED BY FREEDOM PLASTICS. | | APPROVAL OF FITTINGS OVER 12" IS | | CONTNGENT UPON REVIEW AND ACCEPTANCE | | OF TEST REPORTS. | | (2) MURIATIC ACID AND COMPRESSED AIR | | LINES,SUBMIT A COMPLETE PIPING DIAGRAMS. | | CNTY WIDE AMENDMENTS SEC 104.2.1 | | END OF COMMENTS |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2000-03-23 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
2000-03-23 |
Time |
16:16 |
Rev Time |
1.25 |
Received By |
tlarge |
Date |
2000-03-23 |
Time |
16:08 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | | | 1)NOTES REFER TO FLOOR DRAINAGE.SUBMIT | | DRAWING FOR ALL FLOOR DRAINAGE TO BE | | PROVIDED.DRAINS SHALL DISCHARGE TO AN | | APPROVED LOCATION.COUNTYWIDE AMENDMENTS | | TO SPC SEC.104.2.1. | | | | 2)SUBMIT DETAILS FOR SUMP PUMP PIPING. | | DRAIN SHALL DISCHARGE TO AN APPROVED | | LOCTION. | | | | 3)PLANS NOTE BACKWASH LINES DISCHARGING | | TO"SANITARY P-TRAP."SUBMIT DETAILS FOR | | THESE CONNECTIONS AND SHOW TERMINATION | | POINTS OF ALL DRAINS. | | | | 4)SUBMIT POTABLE WATER RISER DIAGRAM | | FOR REVIEW. | | | | 5)SUBMIT PIPING DIAGRAMS FOR POOL ACID | | AND COMPRESSED AIR PIPING. | | COUNTYWIDE AMENDMENTS TO SPC SEC.104.2.1 | | | | THE ABOVE INFORMATION MUST BE SUBMITTED | | PRIOR TO ROUGH PLBG. INSPECTION. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2000-02-26 |
|
|
Cont ID |
|
Sent By |
tlarge |
Date |
2000-02-26 |
Time |
08:26 |
Rev Time |
2.00 |
Received By |
tlarge |
Date |
2000-02-26 |
Time |
08:26 |
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | ******************PROVISO*************** | | PIPING SCHEMATICS REQD.FOR POOL ACID AND | | COMPRESSED AIR PIPING PRIOR TO RGH. | | INSPECTION. | | | | SUBMIT DETAILS/RISER DIAGRAM FOR FLOOR | | DRAINAGE.DRAINS SHALL DISCHARGE TO | | AN APPROVED LOCATION. | | COUNTYWIDE AMENDMENTS TO SPC SEC.104.2.1 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2000-03-10 |
|
|
Cont ID |
|
Sent By |
bstaples |
Date |
2000-03-10 |
Time |
09:50 |
Rev Time |
1.00 |
Received By |
bstaples |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2001-01-08 00:00:00 | APPROVED DENNIS CAMPBELL 3/8/00 |
|
|