2001-01-08 00:00:00PASSED WITH PROVISOS:
 THIS REVIEW ONLY COVERS THE DRIVEWAY
 APPROACH AND NORTH/SOUTH SIDEWALK FROM
 THE STREET TO THE EXISTING EAST/WEST
 SIDEWALK.
 A SEPARATE RIGHT OF WAY PERMIT IS
 REQUIRED.FILL OUT THE ATTACHED FORM
 AND SUBMIT IT TO THE ENGINEERING
 DEPARTMENT AT 1000- 45TH STREET,
 ATTENTION DAN YEAKEL.THIS PERMIT MUST
 BE ISSUED PRIOR TO STARTING WORK.
 NORTH/SOUTH SIDEWALK SECTION MUST BE A
 MINIMUM OF 4" THICK, NEW CONCRETE.
 NEW DRIVEWAY MUST BE MOVED A MINIMUM OF
 THREE FEET TO THE WEST TO KEEP THE
 APPROACH FROM BEING IN FRONT OF THE
 PROPERTY TO THE EAST.
 USE THE ATTACHED DETAIL SHEET FOR THE
 LAY-OUT OF THE APPROACH. PRIOR TO
 POURING THE APPROACH CALL ED RYAN AT
 659-8040 TO COME OUT AND CHECK TO BE
 SURE THAT THE DRIVEWAY IS SET AT THE
 RIGHT ELEVATION.FAILURE TO DO SO WILL
 CAUSE THE DRIVEWAY TO BE REMOVED AND
 REPOURED.
 TIE THE NEW APPROACH IN WITH THE
 EXISTING CURBS ON EITHER SIDE.
 REMOVE THE SIDEWALK IN THE AREA OF THE
 DRIVEWAY APPROACH AND REPLACE IT WITH
 6" CONCRETE.